SmartReader Plus 32KB, 4 channel temperature data logger. Capable of storing up to 21,500 measurements.
SmartReader Plus 32KB, 4 channel temperature data logger. Capable of storing up to 21,500 measurements.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
The SmartReader Plus 3 easily and accurately records AC Current and Voltage (requires separate transducer). Simply connect the logger to ACR's current probes which are then clamped around the conductors, wire the voltage transducer option and begin recording. From this data, total energy consumption (kWh) can be determined for a given period using TrendReader software.
GENERAL SPECIFICATIONS | |
Catalog Number (SRP-003) | 01-0010 |
Catalog Number (SRP-003-128K) | 01-0114 |
Catalog Number (SRP-003-1.5M) | 01-0143 |
Size | 107mm x 74mm x 22mm (4.2" x 2.9" x 0.9") |
Weight | 110 g (3.75 oz) |
Case Material | Noryl® Plastic |
Battery | 3.6 volt Lithium, 1 Amp-Hour |
Resolution | 12-bit (1 part in 4096) |
Mounting | Magnetic backing or locking eyelet |
Clock Accuracy | ± 2 seconds per day |
Sampling Methods |
Continuous (First-in First-out), Stop When Full (Fill-then-stop) *Not available with sample rates faster than eight seconds. |
Operating Limits | -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing) |
PC Requirements | Windows PC with at least one free USB or serial port (depending on interface) |
Software Requirements | TrendReader® 2 (Compatible with Windows 2000 SP4, XP SP1 and Vista 32 bit) |
Memory Size (3 models available) |
128 KB (capable of storing up to 87,000 readings 1.5MB (capable of storing up to 1,048,000 readings) |
Sampling Rates |
User selectable rates from 25 per second to once every eight hours (BP-101 battery pack or PS-201 power supply required for sampling rates faster than eight seconds) |
Number of Channels |
Eight (8):
|
SENSOR SPECIFICATIONS | ||
Internal Temperature Sensor | ||
Type | NTC Thermistor - 10,000 Ohm @ 25°C (77°F) | |
Range | -40°C to 70°C (-40°F to 158°F) | |
Accuracy | ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F) | |
Resolution |
0.03°C (0.05°F) @ 25°C; better than 0.07°C (0.12°F) between -25°C and 70°C (-13°F and 158°F); better than 0.13°C (0.23°F) between -40°C and -25°C (-40°F and -13°F) |
|
Current Sensors | Range | Catalog Number |
A60FL (60 Hz) | 5, 25, 100, 250 Amps | 35-0004 |
A65FL (50 Hz) | 5, 25, 100, 250 Amps | 35-0006 |
A70FL (60 Hz) | 10, 50, 250, 500 Amps | 35-0005 |
A75FL (50 Hz) | 10, 50, 250, 500 Amps | 35-0007 |
Nominal Voltage Ranges | Accuracy | |
120V (1 phase, 60 Hz) | Current channels: ±3.0% of full scale above 10% of range | |
480V 3 phase, 60Hz) | Voltage channels: ±0.5% of full scale |
Click on a category to view a selection of compatible accessories with the ACR 01-0010 SmartReader Plus.
GENERAL SPECIFICATIONS | |
Catalog Number (SRP-003) | 01-0010 |
Catalog Number (SRP-003-128K) | 01-0114 |
Catalog Number (SRP-003-1.5M) | 01-0143 |
Size | 107mm x 74mm x 22mm (4.2" x 2.9" x 0.9") |
Weight | 110 g (3.75 oz) |
Case Material | Noryl® Plastic |
Battery | 3.6 volt Lithium, 1 Amp-Hour |
Resolution | 12-bit (1 part in 4096) |
Mounting | Magnetic backing or locking eyelet |
Clock Accuracy | ± 2 seconds per day |
Sampling Methods |
Continuous (First-in First-out), Stop When Full (Fill-then-stop) *Not available with sample rates faster than eight seconds. |
Operating Limits | -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing) |
PC Requirements | Windows PC with at least one free USB or serial port (depending on interface) |
Software Requirements | TrendReader® 2 (Compatible with Windows 2000 SP4, XP SP1 and Vista 32 bit) |
Memory Size (3 models available) |
128 KB (capable of storing up to 87,000 readings 1.5MB (capable of storing up to 1,048,000 readings) |
Sampling Rates |
User selectable rates from 25 per second to once every eight hours (BP-101 battery pack or PS-201 power supply required for sampling rates faster than eight seconds) |
Number of Channels |
Eight (8):
|
SENSOR SPECIFICATIONS | ||
Internal Temperature Sensor | ||
Type | NTC Thermistor - 10,000 Ohm @ 25°C (77°F) | |
Range | -40°C to 70°C (-40°F to 158°F) | |
Accuracy | ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F) | |
Resolution |
0.03°C (0.05°F) @ 25°C; better than 0.07°C (0.12°F) between -25°C and 70°C (-13°F and 158°F); better than 0.13°C (0.23°F) between -40°C and -25°C (-40°F and -13°F) |
|
Current Sensors | Range | Catalog Number |
A60FL (60 Hz) | 5, 25, 100, 250 Amps | 35-0004 |
A65FL (50 Hz) | 5, 25, 100, 250 Amps | 35-0006 |
A70FL (60 Hz) | 10, 50, 250, 500 Amps | 35-0005 |
A75FL (50 Hz) | 10, 50, 250, 500 Amps | 35-0007 |
Nominal Voltage Ranges | Accuracy | |
120V (1 phase, 60 Hz) | Current channels: ±3.0% of full scale above 10% of range | |
480V 3 phase, 60Hz) | Voltage channels: ±0.5% of full scale |
Click on a category to view a selection of compatible accessories with the ACR 01-0010 SmartReader Plus.