Its dual displays allows viewing amperage and voltage simultaneously. True RMS voltage and current measurements for more precise results when measuring in noisy AC environments.
Its dual displays allows viewing amperage and voltage simultaneously. True RMS voltage and current measurements for more precise results when measuring in noisy AC environments.
Features
Display | 3-3/4 digits 4000 counts, dual LCD displays |
Update Rate | 3 per second nominal |
Low Battery Indication | Below approx. 2.4V |
Operating Temperature | 32°F to 104°F (0°C to 40°C) |
Relative Humidity | Maximum relative humidity 80% for temperatures up to 31°C (88°F) decreasing linearly to 50% relative humidity at 40°C (104°F) |
Altitude | Indoor operation below 2000m (6,562 ft) |
Temperature Coefficient | Nominal 0.15 x (specified accuracy)/°F @ 0°C - 18°C or 28°C - 40°C (32°F -64°F or 82°F - 104°F), or otherwise specified |
Sensing | Average sensing for ACD-14 FX |
Power Supply | Two 3V alkaline button batteries (ANSI/NEDA-5004LC, IEC-CR2032) |
Battery Life | 95 hours approx. (in DCV mode) |
Power Consumption | 2.5 mA typical for ACD-14 FX |
Auto Power Off | After being idle for 30 minutes |
APO Consumption | ACD-14 TRMS-PLUS: 0.8μA typical except 25μA typical for temperature function |
Transient Protection | 6.5kV (1.2/50μs surge) for all models |
Overload Protections | ACA Clamp-on jaws: AC 600A RMS continuous "+" & "COM" terminals (all functions): 600VDC/VAC RMS |
Display | 3-3/4 digits 4000 counts, dual LCD displays |
Update Rate | 3 per second nominal |
Low Battery Indication | Below approx. 2.4V |
Operating Temperature | 32°F to 104°F (0°C to 40°C) |
Relative Humidity | Maximum relative humidity 80% for temperatures up to 31°C (88°F) decreasing linearly to 50% relative humidity at 40°C (104°F) |
Altitude | Indoor operation below 2000m (6,562 ft) |
Temperature Coefficient | Nominal 0.15 x (specified accuracy)/°F @ 0°C - 18°C or 28°C - 40°C (32°F -64°F or 82°F - 104°F), or otherwise specified |
Sensing | Average sensing for ACD-14 FX |
Power Supply | Two 3V alkaline button batteries (ANSI/NEDA-5004LC, IEC-CR2032) |
Battery Life | 95 hours approx. (in DCV mode) |
Power Consumption | 2.5 mA typical for ACD-14 FX |
Auto Power Off | After being idle for 30 minutes |
APO Consumption | ACD-14 TRMS-PLUS: 0.8μA typical except 25μA typical for temperature function |
Transient Protection | 6.5kV (1.2/50μs surge) for all models |
Overload Protections | ACA Clamp-on jaws: AC 600A RMS continuous "+" & "COM" terminals (all functions): 600VDC/VAC RMS |