Amprobe ALC-110 Leakage Current Clamp

Model: ALC-110 | UPC: 095969860116

Amprobe ALC-110 Leakage Current Clamp

Model: ALC-110 | UPC: 095969860116

Designed to resist external magnetic fields for highly accurate readings, along with a mechanical jaw lock to assure the accuracy of low current measurements, avoiding disturbance from measured wires and magnetic fields. It features True RMS measurements for accuracy when measuring complex, non-sinusoidal waveforms.

Designed to resist external magnetic fields for highly accurate readings, along with a mechanical jaw lock to assure the accuracy of low current measurements, avoiding disturbance from measured wires and magnetic fields. It features True RMS measurements for accuracy when measuring complex, non-sinusoidal waveforms.

Sale Price $584.30 USD
Regular Price $751.99 USD
Availability 2 to 3 Weeks
Quantity

Traceable In-House Calibration Certificate for your ALC-110 Leakage Current Clamp

Traceable In-House Calibration Certificate for your ALC-110 Leakage Current Clamp

Amprobe ALC-110 Offers

Features

  • Low influence of external low frequency magnetic fields: @ IN: 3.500 to 600.0 mA ≤30 A/m, operating class 2
  • True-RMS measurements for accuracy when measuring complex, non-sinusoidal waveforms
  • Mechanical jaw lock to assure accuracy of low current measurements, avoiding disturbance from measured wires and magnetic fields; jaw opening 1.2" (30 mm)
  • Highest resolution of 0.001 mA, measure up to 60 A
  • Broad frequency range 15 Hz to 1 kHz for a variety of different applications, including industrial and railway
  • Selectable filters:
    • Low Pass 50/60Hz filter to perform measurements on equipment driven by Variable Frequency Drives (VFDs) or affected by high frequency noise
    • Appliance Filter to conduct leakage current measurements on appliances
    • No filter
  • Selectable limits: 0.25, 0.5, 3.5, 10, and 12 mA
  • Max readings and hold function
  • High safety rating: CAT III 600 V
  • Battery-saving design with an auto backlight off and auto power off

Applications

  • Measure: earth and differential leakage currents, leakage currents through the earth (PE) conductor, appliance current consumption without interruptions to the circuit
  • Trace the source of earth leakage current
  • Identify intermittent GFCI trips without switching equipment off
  • Check a system for an electrical break of insulation where current is flowing to the ground
  • Where industrial leakage current testing is required

Amprobe ALC-110 Specifications

Low Frequency Magnetic Fields ≤30 A/m, operating class 2 @ IN : 3.500 to 600.0 mA/40 Hz to 1 kHz
Safety, Measurement Category CAT III 600 V
AC Frequency 15 Hz to 1 kHz
Low Pass Filter 50 to 60 Hz, for appliance measuring acc. EN61557-16 amendment A, no filter
Limit Judgement 0.25, 0.5, 3.5, 10, 12 mA
Jaw Opening 1.2" (30 mm) max.
Overload Protection 60 A
Auto Power Off Idle 20 minutes
Display Digital: 6000 counts, updates 5/sec
Range Auto ranging
Over Range Indication OL or -OL
Operating Temperature 32 to 86°F (0 to 30°C), ≤80% RH
86 to 104°F (30 to 40°C), ≤75% RH
104 to 122°F (40 to 50°C), ≤45% RH
Storage Temperature -4 to 140°F (-20 to 60°C)
Pollution Degree 2
Temperature Coefficient 0.1 x (specified accuracy)/°C (<21°C, >25°C)
Vibration Requirement acc. IEC 61557-1 clause 4.10
Drop Proof 4' (1.2 m)
Battery Type: 2 x batteries 1.5 V IEC LR03 AAA
Life: 60 hours typical
Safety Compliance IEC/EN 61010-1, IEC/EN 61010-2-032, IEC/EN 61557-13
EMC Compliance IEC/EN 61326-1, IEC/EN 61326-2-2
Agency Approvals CSA, CE
Dimensions 8.7 x 3.5 x 1.8" (221 x 89 x 48 mm)
Weight 0.9 lb (410 g) with batteries installed
Click here for complete specifications on the Amprobe ALC-110

What's included with the Amprobe ALC-110

  • Leakage Current Clamp
  • 2 x AAA Batteries
  • Soft Carrying Case
  • User Manual

Ask a question about Amprobe ALC-110 Leakage Current Clamp

Customer Reviews for the Amprobe ALC-110

Amprobe ALC-110 Offers

Features

  • Low influence of external low frequency magnetic fields: @ IN: 3.500 to 600.0 mA ≤30 A/m, operating class 2
  • True-RMS measurements for accuracy when measuring complex, non-sinusoidal waveforms
  • Mechanical jaw lock to assure accuracy of low current measurements, avoiding disturbance from measured wires and magnetic fields; jaw opening 1.2" (30 mm)
  • Highest resolution of 0.001 mA, measure up to 60 A
  • Broad frequency range 15 Hz to 1 kHz for a variety of different applications, including industrial and railway
  • Selectable filters:
    • Low Pass 50/60Hz filter to perform measurements on equipment driven by Variable Frequency Drives (VFDs) or affected by high frequency noise
    • Appliance Filter to conduct leakage current measurements on appliances
    • No filter
  • Selectable limits: 0.25, 0.5, 3.5, 10, and 12 mA
  • Max readings and hold function
  • High safety rating: CAT III 600 V
  • Battery-saving design with an auto backlight off and auto power off

Applications

  • Measure: earth and differential leakage currents, leakage currents through the earth (PE) conductor, appliance current consumption without interruptions to the circuit
  • Trace the source of earth leakage current
  • Identify intermittent GFCI trips without switching equipment off
  • Check a system for an electrical break of insulation where current is flowing to the ground
  • Where industrial leakage current testing is required

Amprobe ALC-110 Specifications

Low Frequency Magnetic Fields ≤30 A/m, operating class 2 @ IN : 3.500 to 600.0 mA/40 Hz to 1 kHz
Safety, Measurement Category CAT III 600 V
AC Frequency 15 Hz to 1 kHz
Low Pass Filter 50 to 60 Hz, for appliance measuring acc. EN61557-16 amendment A, no filter
Limit Judgement 0.25, 0.5, 3.5, 10, 12 mA
Jaw Opening 1.2" (30 mm) max.
Overload Protection 60 A
Auto Power Off Idle 20 minutes
Display Digital: 6000 counts, updates 5/sec
Range Auto ranging
Over Range Indication OL or -OL
Operating Temperature 32 to 86°F (0 to 30°C), ≤80% RH
86 to 104°F (30 to 40°C), ≤75% RH
104 to 122°F (40 to 50°C), ≤45% RH
Storage Temperature -4 to 140°F (-20 to 60°C)
Pollution Degree 2
Temperature Coefficient 0.1 x (specified accuracy)/°C (<21°C, >25°C)
Vibration Requirement acc. IEC 61557-1 clause 4.10
Drop Proof 4' (1.2 m)
Battery Type: 2 x batteries 1.5 V IEC LR03 AAA
Life: 60 hours typical
Safety Compliance IEC/EN 61010-1, IEC/EN 61010-2-032, IEC/EN 61557-13
EMC Compliance IEC/EN 61326-1, IEC/EN 61326-2-2
Agency Approvals CSA, CE
Dimensions 8.7 x 3.5 x 1.8" (221 x 89 x 48 mm)
Weight 0.9 lb (410 g) with batteries installed
Click here for complete specifications on the Amprobe ALC-110

What's included with the Amprobe ALC-110

  • Leakage Current Clamp
  • 2 x AAA Batteries
  • Soft Carrying Case
  • User Manual

Ask a question about Amprobe ALC-110 Leakage Current Clamp

Customer Reviews for the Amprobe ALC-110

More Amprobe Products

Calibration Lab