Autonics FXY Series Digital Counter/Timer Indicator, 6-digit, 100 to 240 V AC/50/60 Hz

Model: FX6Y-I4

Autonics FXY Series Digital Counter/Timer Indicator, 6-digit, 100 to 240 V AC/50/60 Hz

Model: FX6Y-I4

For accurate measurement and display of many system configurations, this digital counter/timer indicator features counting speeds of 1 cps, 30 cps, 2 kcps, and 5 kcps and multiple time setting ranges. In addition, this indicator features a DIN size of 2.83 x 1.41" (72 x 36 mm) and count-up, count-down, and count-up/down modes.

For accurate measurement and display of many system configurations, this digital counter/timer indicator features counting speeds of 1 cps, 30 cps, 2 kcps, and 5 kcps and multiple time setting ranges. In addition, this indicator features a DIN size of 2.83 x 1.41" (72 x 36 mm) and count-up, count-down, and count-up/down modes.

Your Price $120.00 USD
Availability 2 to 3 Weeks
Quantity

Autonics FX6Y-I4 Offers

Features

  • Counting speeds: 1 cps/30 cps/2 kcps/5 kcps
  • Switch between counter and timer operation using DIP switch
  • Switch between voltage input (PNP) and no-voltage input (PNP) using DIP switch
  • Set decimal point, hour/minute/second display with RESET key
  • Operation modes: count-up, count-down, count-up/down (counter)
  • Counter; 20 input modes
  • Timer; Time setting range: 0.01 seconds to 99999.9 hour
  • Power supply: 100 to 240 V AC/50/60 Hz

Applications

  • Measurement and display of various system configurations

Autonics FX6Y-I4 Specifications

Display 6-digit 7-segment LED
Counter 0.15 x 0.31" (4 x 8 mm)
Maximum Counting Speed 1, 30, 1 k, 5 k cps
Minimum Signal Width Inhibit, reset: ≈ 20 ms
Input Logic Voltage input (PNP) - input impedance: 10.8 kΩ, [H]: 5 to 30 V DC, [L]: 0 to 2 V DC
No-voltage input (NPN) - short-circuit impedance: ≤470 Ω, short-circuit residual voltage: ≤1 V DC
open-circuit impedance: ≥100 kΩ
Error Repeat/SET/voltage/temperature: ≤±0.01% ±0.05 seconds
Operation Method Counter: Count up, count down, count up/down
Timer: Count up, count down
Terminal Terminal block
Time Operation Power on start
Memory Retention Approximately 10 years (non-volatile semiconductor memory type)
Insulation Resistance ≥100 MΩ (500 V DC megger)
Dielectric Strength Between all terminals and case: 2000 V AC 50/60 Hz for 1 minute
Noise Immunity ±2 kV square wave noise (pulse width: 1 μs) by the noise simulator
Vibration 0.029" (0.75 mm) double amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z direction for 1 hour
Malfunction: 0.019" (0.5 mm) double amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z direction for 10 minute
Shock 300 m/s² (≈ 30 G) in each X, Y, Z direction for 3 times
Malfunction: 100 m/s² (≈ 10 G) in each X, Y, Z direction for 3 times
Setting Range =0.1 to 99999.9 seconds, 1 to 999999 seconds, 0.01 seconds to 99 minutes and 59.99 seconds, 0.1 seconds to 999 minutes and 59.9 seconds, 0.1 to 99999.9 minutes, 1 seconds to 99 hours, 59 minutes, and 59 seconds, 1 minute to 9999 hours and 59 minutes, 0.1 to 99999.9 hours
Control Output Type Indicator
Protection Structure IP40 (front part, IEC standard)
Environment Ambient temperature: 14 to 131°F (-10 to 55°C), storage: -13 to 149°F (-25 to 65°C)
Ambient humidity: 35 to 85% RH, storage: 35 to 85% RH
Power Supply: 100 to 240 V AC, ±10% 50/60 Hz
Consumption: ≤3.8 V A
External supply: ≤12 V DC, ±10%, 50 mA
Dimensions 2.83 x 1.41" (72 x 36 mm)
Weight 0.26 lbs (120 g)

What's included with the Autonics FX6Y-I4

  • Counter/Timer Indicator
  • 2 x Bracket
  • Instruction Manual

Ask a question about Autonics FXY Series Digital Counter/Timer Indicator, 6-digit, 100 to 240 V AC/50/60 Hz

Customer Reviews for the Autonics FX6Y-I4

Autonics FX6Y-I4 Offers

Features

  • Counting speeds: 1 cps/30 cps/2 kcps/5 kcps
  • Switch between counter and timer operation using DIP switch
  • Switch between voltage input (PNP) and no-voltage input (PNP) using DIP switch
  • Set decimal point, hour/minute/second display with RESET key
  • Operation modes: count-up, count-down, count-up/down (counter)
  • Counter; 20 input modes
  • Timer; Time setting range: 0.01 seconds to 99999.9 hour
  • Power supply: 100 to 240 V AC/50/60 Hz

Applications

  • Measurement and display of various system configurations

Autonics FX6Y-I4 Specifications

Display 6-digit 7-segment LED
Counter 0.15 x 0.31" (4 x 8 mm)
Maximum Counting Speed 1, 30, 1 k, 5 k cps
Minimum Signal Width Inhibit, reset: ≈ 20 ms
Input Logic Voltage input (PNP) - input impedance: 10.8 kΩ, [H]: 5 to 30 V DC, [L]: 0 to 2 V DC
No-voltage input (NPN) - short-circuit impedance: ≤470 Ω, short-circuit residual voltage: ≤1 V DC
open-circuit impedance: ≥100 kΩ
Error Repeat/SET/voltage/temperature: ≤±0.01% ±0.05 seconds
Operation Method Counter: Count up, count down, count up/down
Timer: Count up, count down
Terminal Terminal block
Time Operation Power on start
Memory Retention Approximately 10 years (non-volatile semiconductor memory type)
Insulation Resistance ≥100 MΩ (500 V DC megger)
Dielectric Strength Between all terminals and case: 2000 V AC 50/60 Hz for 1 minute
Noise Immunity ±2 kV square wave noise (pulse width: 1 μs) by the noise simulator
Vibration 0.029" (0.75 mm) double amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z direction for 1 hour
Malfunction: 0.019" (0.5 mm) double amplitude at frequency of 10 to 55 Hz (for 1 minute) in each X, Y, Z direction for 10 minute
Shock 300 m/s² (≈ 30 G) in each X, Y, Z direction for 3 times
Malfunction: 100 m/s² (≈ 10 G) in each X, Y, Z direction for 3 times
Setting Range =0.1 to 99999.9 seconds, 1 to 999999 seconds, 0.01 seconds to 99 minutes and 59.99 seconds, 0.1 seconds to 999 minutes and 59.9 seconds, 0.1 to 99999.9 minutes, 1 seconds to 99 hours, 59 minutes, and 59 seconds, 1 minute to 9999 hours and 59 minutes, 0.1 to 99999.9 hours
Control Output Type Indicator
Protection Structure IP40 (front part, IEC standard)
Environment Ambient temperature: 14 to 131°F (-10 to 55°C), storage: -13 to 149°F (-25 to 65°C)
Ambient humidity: 35 to 85% RH, storage: 35 to 85% RH
Power Supply: 100 to 240 V AC, ±10% 50/60 Hz
Consumption: ≤3.8 V A
External supply: ≤12 V DC, ±10%, 50 mA
Dimensions 2.83 x 1.41" (72 x 36 mm)
Weight 0.26 lbs (120 g)

What's included with the Autonics FX6Y-I4

  • Counter/Timer Indicator
  • 2 x Bracket
  • Instruction Manual

Ask a question about Autonics FXY Series Digital Counter/Timer Indicator, 6-digit, 100 to 240 V AC/50/60 Hz