Versatile, this sweep function generator features a sine and square frequency range from 0.1 Hz to 7 MHz and a triangle/ramp frequency range from 0.1 Hz to 1 MHz. With an advanced direct digital synthesis (DDS) design, this generator generates sine, square, and triangle waveforms with high signal precision and stability.
Versatile, this sweep function generator features a sine and square frequency range from 0.1 Hz to 7 MHz and a triangle/ramp frequency range from 0.1 Hz to 1 MHz. With an advanced direct digital synthesis (DDS) design, this generator generates sine, square, and triangle waveforms with high signal precision and stability.
Features
Frequency | |
Sine | 0.1 Hz to 7 MHz |
Square | 0.1 Hz to 7 MHz |
Triangle | 0.1 Hz to 1 MHz |
Resolution | 5 digits or 100 mHz |
Accuracy | 0.01% ±0.186 Hz |
Output | |
Amplitude | Range: 20 mVpp to 20 Vpp (open circuit) 10 mVpp to 10 Vpp (into 50 Ω) Resolution: 3 digits (1000 counts) Accuracy: ±2% ±20 mV of programmed output from 1.01 to 10 V |
Flatness | ±1 dB to 7 MHz |
DC Offset | Range: -4.5 to 4.5 V (into 50 Ω) Resolution: 10 mV, 3 digits Accuracy: ±2% ±10 mV (into 50 Ω) |
Output | Impedance: 50 Ω ±2% Protection: Protected against short circuit or accidental over-voltage practically available in electronic laboratories, applied to the main output connector |
Waveform | |
Harmonic Distortion (at 10 Vp-p into 50 Ω) | DC - 100 kHz, -55 dBc 100 kHz - 1 MHz, < -45 dBc 1 MHz – 7 MHz, < -30 dBc |
Square Rise/Fall Time | ≤ 20 ns (10 to 90% at full amplitude into 50 Ω) |
Duty Cycle | Adjustable 20 to 80% up to 1 MHz for square and triangle |
Symmetry Accuracy at 50% | ±1% |
Sweep | |
Shape | Linear or Logarithmic, up or down Time: 20 ms to 100 s |
Input and Output | |
Sync Out | TTL pulse at programmed frequency; 50 Ω source impedance |
General Specifications | |
Memory Storage | 9 instrument settings |
Power Requirements | 100 to 240 V AC ±10% |
Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: 14 to 158°F (-10 to 70°C) |
Humidity | 95% RH 32 to 86&def;F (0 to 30°C) |
Dimensions | 8.39 x 3.46 x 8.27" (213 x 88 x 210 mm) |
Weight | 4.4 lbs (2 kg) |
Frequency | |
Sine | 0.1 Hz to 7 MHz |
Square | 0.1 Hz to 7 MHz |
Triangle | 0.1 Hz to 1 MHz |
Resolution | 5 digits or 100 mHz |
Accuracy | 0.01% ±0.186 Hz |
Output | |
Amplitude | Range: 20 mVpp to 20 Vpp (open circuit) 10 mVpp to 10 Vpp (into 50 Ω) Resolution: 3 digits (1000 counts) Accuracy: ±2% ±20 mV of programmed output from 1.01 to 10 V |
Flatness | ±1 dB to 7 MHz |
DC Offset | Range: -4.5 to 4.5 V (into 50 Ω) Resolution: 10 mV, 3 digits Accuracy: ±2% ±10 mV (into 50 Ω) |
Output | Impedance: 50 Ω ±2% Protection: Protected against short circuit or accidental over-voltage practically available in electronic laboratories, applied to the main output connector |
Waveform | |
Harmonic Distortion (at 10 Vp-p into 50 Ω) | DC - 100 kHz, -55 dBc 100 kHz - 1 MHz, < -45 dBc 1 MHz – 7 MHz, < -30 dBc |
Square Rise/Fall Time | ≤ 20 ns (10 to 90% at full amplitude into 50 Ω) |
Duty Cycle | Adjustable 20 to 80% up to 1 MHz for square and triangle |
Symmetry Accuracy at 50% | ±1% |
Sweep | |
Shape | Linear or Logarithmic, up or down Time: 20 ms to 100 s |
Input and Output | |
Sync Out | TTL pulse at programmed frequency; 50 Ω source impedance |
General Specifications | |
Memory Storage | 9 instrument settings |
Power Requirements | 100 to 240 V AC ±10% |
Temperature | Operating: 32 to 122°F (0 to 50°C) Storage: 14 to 158°F (-10 to 70°C) |
Humidity | 95% RH 32 to 86&def;F (0 to 30°C) |
Dimensions | 8.39 x 3.46 x 8.27" (213 x 88 x 210 mm) |
Weight | 4.4 lbs (2 kg) |