Image is for reference only, refer to product info for complete details.
Bezel provides flange for flush mounting in panel. Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.
Bezel provides flange for flush mounting in panel. Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.
Dwyer 2300-00 Differential pressure gauge, range 0.125-0-0.125" w.c. (inches of water), minor divisions .005, calibrated for vertical scale position
Using Dwyer's simple, frictionless Magnehelic gauge movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It's inexpensive, too.
The Magnehelic gauge is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment.
Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.
Service | Air and non-combustible, compatible gases May be used with hydrogen Pressures must be less than 35 psi |
Housing | Die cast aluminum case and bezel, with acrylic cover Exterior finish is coated gray to withstand 168 hour salt spray corrosion test |
Accuracy | ±2% (-HA model ±1) of FS (±3% (-HA ±1.5%) on -0, -100 PA, -125 PA, -10 MM ±4% (-HA ±2%) on -00, -60PA, -6MM ranges), throughout range at 70°F (21.1°C) |
Pressure Limits | -20 in Hg. to 15 psig.† (-0.677 bar to 1.034 bar) MP option: 35 psig (2.41 bar), HP option: 80 psig (5.52 bar) |
Enclosure Rating | IP67 |
Overpressure | Relief plug opens at approximately 25 psig (1.72 bar), standard gages only |
Temperature Limits | 20 to 140°F (-6.67 to 60°C) -20°F (-28°C) with low temperature option |
Mounting Orientation | Diaphragm in vertical position |
Process Connections | ⅛" emale NPT duplicate high and low pressure taps - one pair side and one pair back |
Dimensions | 4" (101.6 mm) diameter dial face |
Service | Air and non-combustible, compatible gases May be used with hydrogen Pressures must be less than 35 psi |
Housing | Die cast aluminum case and bezel, with acrylic cover Exterior finish is coated gray to withstand 168 hour salt spray corrosion test |
Accuracy | ±2% (-HA model ±1) of FS (±3% (-HA ±1.5%) on -0, -100 PA, -125 PA, -10 MM ±4% (-HA ±2%) on -00, -60PA, -6MM ranges), throughout range at 70°F (21.1°C) |
Pressure Limits | -20 in Hg. to 15 psig.† (-0.677 bar to 1.034 bar) MP option: 35 psig (2.41 bar), HP option: 80 psig (5.52 bar) |
Enclosure Rating | IP67 |
Overpressure | Relief plug opens at approximately 25 psig (1.72 bar), standard gages only |
Temperature Limits | 20 to 140°F (-6.67 to 60°C) -20°F (-28°C) with low temperature option |
Mounting Orientation | Diaphragm in vertical position |
Process Connections | ⅛" emale NPT duplicate high and low pressure taps - one pair side and one pair back |
Dimensions | 4" (101.6 mm) diameter dial face |