Dwyer CDT-2N44 Wall Mount Carbon Dioxide/Temperature Transmitter, 2000 ppm, 32 to 122°F

Model: CDT-2N44

Dwyer CDT-2N44 Wall Mount Carbon Dioxide/Temperature Transmitter, 2000 ppm, 32 to 122°F

Model: CDT-2N44

Accurately monitor the CO2 concentration and temperature in indoor environments to help energy savings with this carbon dioxide and temperature transmitter. In addition, it features barometric pressure adjustment and a 4 to 20 mA/0 to (5 or 10) V DC CO2 and temperature outputs.

Accurately monitor the CO2 concentration and temperature in indoor environments to help energy savings with this carbon dioxide and temperature transmitter. In addition, it features barometric pressure adjustment and a 4 to 20 mA/0 to (5 or 10) V DC CO2 and temperature outputs.

Sale Price $219.07 USD
Regular Price $234.30 USD
Availability 5 Days
Quantity

Dwyer CDT-2N44 Offers

Features

  • Minimize inventory and save time by combining CO2 and temperature measurements into one transmitter
  • Requires minimal maintenance with Automatic Baseline Correction (ABC) to account for sensor drift
  • Reduce operation costs using low energy, reliable, and repeatable CO2 sensor
  • Simplify installation with backplate electrical connection
  • Wall mount
  • Universal current/voltage output

Applications

  • Demand control ventilation in schools, office buildings, hospitals, and other indoor environments
  • LEED® certification

Dwyer CDT-2N44 Specifications

Range CO2: 0 to 2000 ppm
Temperature: 32 to 122°F (0 to 50°C)
Accuracy CO2: ±40 ppm + 3% of reading
Temperature: ±1°C at 25°C
Response Time 2 minutes for 90% step change
Limits Temperature: 32 to 122°F (0 to 50°C)
Humidity: 0 to 85% (non-condensing)
Sensor NDIR, 15 year life expectancy
Output Current: 4 to 20 mA (maximum 500 Ω)
Voltage: 0 to 5 V DC or 0 to 10 V DC (minimum 500 Ω)
Power Requirements: 16 to 35 V DC or 19 to 28 V AC
Consumption: 2 W (average); 3.75 W (peak)
Compliance CE
Dimensions 4.5 x 2.8 x 1.1" (114.3 x 71.12 x 27.96 mm)
Click here for complete specifications on the Dwyer CDT-2N44

What's included with the Dwyer CDT-2N44

  • Dwyer CDT-2N44 Wall Mount Carbon Dioxide/Temperature Transmitter, 2000 ppm, 32 to 122°F

Ask a question about Dwyer CDT-2N44 Wall Mount Carbon Dioxide/Temperature Transmitter, 2000 ppm, 32 to 122°F

Customer Reviews for the Dwyer CDT-2N44

Dwyer CDT-2N44 Offers

Features

  • Minimize inventory and save time by combining CO2 and temperature measurements into one transmitter
  • Requires minimal maintenance with Automatic Baseline Correction (ABC) to account for sensor drift
  • Reduce operation costs using low energy, reliable, and repeatable CO2 sensor
  • Simplify installation with backplate electrical connection
  • Wall mount
  • Universal current/voltage output

Applications

  • Demand control ventilation in schools, office buildings, hospitals, and other indoor environments
  • LEED® certification

Dwyer CDT-2N44 Specifications

Range CO2: 0 to 2000 ppm
Temperature: 32 to 122°F (0 to 50°C)
Accuracy CO2: ±40 ppm + 3% of reading
Temperature: ±1°C at 25°C
Response Time 2 minutes for 90% step change
Limits Temperature: 32 to 122°F (0 to 50°C)
Humidity: 0 to 85% (non-condensing)
Sensor NDIR, 15 year life expectancy
Output Current: 4 to 20 mA (maximum 500 Ω)
Voltage: 0 to 5 V DC or 0 to 10 V DC (minimum 500 Ω)
Power Requirements: 16 to 35 V DC or 19 to 28 V AC
Consumption: 2 W (average); 3.75 W (peak)
Compliance CE
Dimensions 4.5 x 2.8 x 1.1" (114.3 x 71.12 x 27.96 mm)
Click here for complete specifications on the Dwyer CDT-2N44

What's included with the Dwyer CDT-2N44

  • Dwyer CDT-2N44 Wall Mount Carbon Dioxide/Temperature Transmitter, 2000 ppm, 32 to 122°F

Ask a question about Dwyer CDT-2N44 Wall Mount Carbon Dioxide/Temperature Transmitter, 2000 ppm, 32 to 122°F

Customer Reviews for the Dwyer CDT-2N44

More Dwyer Products

Calibration Lab