Dwyer IS626-13-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-300 psig)

Model: IS626-13-GH-P1-E1-S1

Dwyer IS626-13-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-300 psig)

Model: IS626-13-GH-P1-E1-S1

Converts pressure into a standard 4-20 mA output signal. Can be used to accurately measure compatible gases and liquids compatible with its 316/316L Stainless Steel wetted parts.

Converts pressure into a standard 4-20 mA output signal. Can be used to accurately measure compatible gases and liquids compatible with its 316/316L Stainless Steel wetted parts.

Sale Price $431.04 USD
Regular Price $461.00 USD
Availability 3 to 4 Weeks
Quantity

Traceable In-House Calibration Certificate for your Dwyer IS626-13-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-300 psig)

Traceable In-House Calibration Certificate for your Dwyer IS626-13-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-300 psig)

Dwyer IS626-13-GH-P1-E1-S1 PRESSURE TRANSMITTER, 0- 300 PSIG

  • Full scale accuracy is 0.25%.
  • Designed for industrial environments with a NEMA 4X (IP66) housing, this transmitter resists most effects of shock and vibration.
  • Models are available with a 3' cable or M-12 4 pin connection.

Specifications

Service: Compatible gases and liquids.
Wetted Materials: Type 316, 316L SS.
Accuracy: 0.25% full scale (includes linearity, hysteresis, and repeatability).
Temperature Limit: 0 to 176°F (-18 to 80°C).
Compensated Temperature Range: 0 to 176°F (-18 to 80°C).
Thermal Effect: ±0.02% FS/°F (includes zero and span).
Power Requirements: 10 to 28 VDC.
Output Signal: 4 to 20 mA.
Response Time: 50 msec.
Loop Resistance: 0-900 ohms maximum.
Current Consumption: 38 mA (maximum).
Electrical Connections: 3 ft. cable or 4-pin M-12 Connector.
Process Connection: 1/4" male/female NPT and BSPT.
Enclosure Rating: NEMA 4X (IP66).
Mounting Orientation: Mount in any position.
Weight: 8.9 oz (252 g).
Agency Approvals: CE, UL and cUL Intrinsically Safe to UL Standard 913.

For use in Hazardous (Classified) Locations:
Class I Div. 1 Groups A,B,C,D; Class II Div. 1 Groups E,F,G; Class III Div. 1.
Temperature Code: T4 @ 80°C ambient.
Install in accordance with control drawing 01-700797-00.
WARNING: To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. Use with approved safety barriers using entity evaluation.

What's included with the Dwyer IS626-13-GH-P1-E1-S1

  • Dwyer IS626-13-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-300 psig)

Click on a category to view a selection of compatible accessories with the Dwyer IS626-13-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-300 psig).

Dwyer MTL7706 Zener Barrier, Is, For Is626, Sbltx & Pbltx Ser MTL7706
Intrinsically safe (IS) shunt-diode barrier that can be used to communicate with and provide isolations for certain Dwyer® transmitters approved for use in hazardous areas. These barriers limit the amount of energy allowed to pass into the hazardous area, which inhibit ignition in flammable atmospheres.




Dwyer MTL5541 Galvanic Isolator, Is, Is626, Sbltx & Pbltx Ser MTL5541
Provides total intrinsically safe isolation for communication with Dwyer® pressure transmitters approved for location in hazardous areas. Galvanic isolation eliminates the need for a high integrity earth ground required when using shunt diode type saf.




Ask a question about Dwyer IS626-13-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-300 psig)

Customer Reviews for the Dwyer IS626-13-GH-P1-E1-S1

Dwyer IS626-13-GH-P1-E1-S1 PRESSURE TRANSMITTER, 0- 300 PSIG

  • Full scale accuracy is 0.25%.
  • Designed for industrial environments with a NEMA 4X (IP66) housing, this transmitter resists most effects of shock and vibration.
  • Models are available with a 3' cable or M-12 4 pin connection.

Specifications

Service: Compatible gases and liquids.
Wetted Materials: Type 316, 316L SS.
Accuracy: 0.25% full scale (includes linearity, hysteresis, and repeatability).
Temperature Limit: 0 to 176°F (-18 to 80°C).
Compensated Temperature Range: 0 to 176°F (-18 to 80°C).
Thermal Effect: ±0.02% FS/°F (includes zero and span).
Power Requirements: 10 to 28 VDC.
Output Signal: 4 to 20 mA.
Response Time: 50 msec.
Loop Resistance: 0-900 ohms maximum.
Current Consumption: 38 mA (maximum).
Electrical Connections: 3 ft. cable or 4-pin M-12 Connector.
Process Connection: 1/4" male/female NPT and BSPT.
Enclosure Rating: NEMA 4X (IP66).
Mounting Orientation: Mount in any position.
Weight: 8.9 oz (252 g).
Agency Approvals: CE, UL and cUL Intrinsically Safe to UL Standard 913.

For use in Hazardous (Classified) Locations:
Class I Div. 1 Groups A,B,C,D; Class II Div. 1 Groups E,F,G; Class III Div. 1.
Temperature Code: T4 @ 80°C ambient.
Install in accordance with control drawing 01-700797-00.
WARNING: To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. Use with approved safety barriers using entity evaluation.

What's included with the Dwyer IS626-13-GH-P1-E1-S1

  • Dwyer IS626-13-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-300 psig)

Click on a category to view a selection of compatible accessories with the Dwyer IS626-13-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-300 psig).

Dwyer MTL7706 Zener Barrier, Is, For Is626, Sbltx & Pbltx Ser MTL7706
Intrinsically safe (IS) shunt-diode barrier that can be used to communicate with and provide isolations for certain Dwyer® transmitters approved for use in hazardous areas. These barriers limit the amount of energy allowed to pass into the hazardous area, which inhibit ignition in flammable atmospheres.




Dwyer MTL5541 Galvanic Isolator, Is, Is626, Sbltx & Pbltx Ser MTL5541
Provides total intrinsically safe isolation for communication with Dwyer® pressure transmitters approved for location in hazardous areas. Galvanic isolation eliminates the need for a high integrity earth ground required when using shunt diode type saf.




Ask a question about Dwyer IS626-13-GH-P1-E1-S1 Intrinsically Safe Pressure Transmitter (0-300 psig)

Customer Reviews for the Dwyer IS626-13-GH-P1-E1-S1

More Dwyer Products

Calibration Lab