FREE SHIPPING ON ONLINE ORDERS OVER $99*

Dwyer MPCJR-485 Pump Controller, w/RS485 Comm Cable

Model: MPCJR-485

Dwyer MPCJR-485 Pump Controller, w/RS485 Comm Cable

Model: MPCJR-485

Selectable pump alternation when used with two pumps to minimize pump wear. Integral 24V DC power supply for transmitter.

Selectable pump alternation when used with two pumps to minimize pump wear. Integral 24V DC power supply for transmitter.

Sale Price $982.69 USD
Regular Price $1051.00 USD
Availability 4 to 5 Weeks
Quantity

Dwyer MPCJR Series Offers

Features

  • User selectable security lock-out of programming and/or set points
  • Optional process input retransmission as a current (4 to 20 mA) or voltage (2 to 10 VDC) analog signal
  • Analog output on pump "on" condition for activation of separate pump run time
Functional Specifications
  • Inputs: 4 (or 0) to 20 mA DC or 2 (or 0) to 10 VDC selectable
  • Input Impedance: Current = 10 ohms, Voltage = 5 K ohms
  • Output Ratings: Control Relays: SPDT, rated 10A @ 240 VAC res., 1/4 hp @ 120 VAC, 1/3 hp @ 240 VAC; Alarm Relays: SPST, 3A @ 240 VAC res., 1/10 hp @ 120 VAC; Others: 15 VDC @ 20 mA for output one and output two
  • Accuracy: ±0.25% of span, ±1 least significant digit
  • Display: Two 4-digit, 7 segment 0.56" high LEDs
  • Display Resolution: 1 count
  • Memory Backup: Nonvolatile memory (no batteries required)
  • Serial Communications: Optional RS-232 or RS-485 with Modbus protocol
  • Ambient Operating Temperature/RH: 14 to 131°F (-10 55°C)/0 to 90% up to 104°F (40°C) non-condensing, 10 to 50% at 131°F (55°C) non-condensing
  • Front Panel Rating: Meets UL Type 4X (IP66)
  • Loop Power Supply (isolated): 24 VDC @ 50 mA, regulated
  • Agency Approvals: CE, cUL, UL
General Specifications
  • Control Type: On/off, reverse (pump out) or direct (pump in) acting
  • Power Requirements: 100 to 240 VAC nominal, +10%-15%, 50 to 400 Hz, single phase; 132 to 240 VDC nominal, +10%-15%
  • Power Consumption: 7.5 VA maximum
  • Weight: 16 oz (454 g)

What's included with the Dwyer MPCJR-485

  • Dwyer MPCJR-485 Pump Controller, w/RS485 Comm Cable

Ask a question about Dwyer MPCJR-485 Pump Controller, w/RS485 Comm Cable

Customer Reviews for the Dwyer MPCJR-485

Dwyer MPCJR Series Offers

Features

  • User selectable security lock-out of programming and/or set points
  • Optional process input retransmission as a current (4 to 20 mA) or voltage (2 to 10 VDC) analog signal
  • Analog output on pump "on" condition for activation of separate pump run time
Functional Specifications
  • Inputs: 4 (or 0) to 20 mA DC or 2 (or 0) to 10 VDC selectable
  • Input Impedance: Current = 10 ohms, Voltage = 5 K ohms
  • Output Ratings: Control Relays: SPDT, rated 10A @ 240 VAC res., 1/4 hp @ 120 VAC, 1/3 hp @ 240 VAC; Alarm Relays: SPST, 3A @ 240 VAC res., 1/10 hp @ 120 VAC; Others: 15 VDC @ 20 mA for output one and output two
  • Accuracy: ±0.25% of span, ±1 least significant digit
  • Display: Two 4-digit, 7 segment 0.56" high LEDs
  • Display Resolution: 1 count
  • Memory Backup: Nonvolatile memory (no batteries required)
  • Serial Communications: Optional RS-232 or RS-485 with Modbus protocol
  • Ambient Operating Temperature/RH: 14 to 131°F (-10 55°C)/0 to 90% up to 104°F (40°C) non-condensing, 10 to 50% at 131°F (55°C) non-condensing
  • Front Panel Rating: Meets UL Type 4X (IP66)
  • Loop Power Supply (isolated): 24 VDC @ 50 mA, regulated
  • Agency Approvals: CE, cUL, UL
General Specifications
  • Control Type: On/off, reverse (pump out) or direct (pump in) acting
  • Power Requirements: 100 to 240 VAC nominal, +10%-15%, 50 to 400 Hz, single phase; 132 to 240 VDC nominal, +10%-15%
  • Power Consumption: 7.5 VA maximum
  • Weight: 16 oz (454 g)

What's included with the Dwyer MPCJR-485

  • Dwyer MPCJR-485 Pump Controller, w/RS485 Comm Cable

Ask a question about Dwyer MPCJR-485 Pump Controller, w/RS485 Comm Cable

Customer Reviews for the Dwyer MPCJR-485

More Dwyer Products

Calibration Lab