FREE SHIPPING ON ONLINE ORDERS OVER $99*

Dwyer RHP-2O1B RHP Series Humidity/Temperature Transmitter, OSA-mount, 2% RH

Model: RHP-2O1B

Dwyer RHP-2O1B RHP Series Humidity/Temperature Transmitter, OSA-mount, 2% RH

Model: RHP-2O1B

Flexible and accurate, this humidity/temperature transmitter features a 2% RH accuracy and a 4 to 20 mA RH output. Easily installed with the outside air mounting configuration, this transmitter provides outdoor temperature and relative humidity reference for building energy management systems.

Flexible and accurate, this humidity/temperature transmitter features a 2% RH accuracy and a 4 to 20 mA RH output. Easily installed with the outside air mounting configuration, this transmitter provides outdoor temperature and relative humidity reference for building energy management systems.

Sale Price $147.96 USD
Regular Price $158.25 USD
Availability 1 Week
Quantity

Dwyer RHP-2O1B Offers

Reduce the long-term effects of condensation, fog, or high humidity with this transmitter that combines the voltage or current humidity transmitter output with a 10K type II NTC passive temperature thermistor output.

Features

  • Reduced installation cost with combined humidity and temperature
  • Wide application environment from a large selection of temperature sensors and 2%, 3% and 5% accuracies
  • Reduced system operating costs with radiation shield protecting the sensor from radiant heat

Applications

  • Air economizers
  • Outdoor temperature and relative humidity reference for building systems

Dwyer RHP-2O1B Specifications

Relative Humidity Range 0 to 100% RH
Temperature Range -40 to 140°F (-40 to 60°C)
Accuracy, RH ±2% 10 to 90% RH at 25°C
Accuracy, Thermistor Temp Sensor ±0.2°C at 25°C (±0.36°F at 77°F)
Accuracy, RTD Temp Sensor DIN Class B; ±0.3°C at 0°C (±0.54°F at 32°F)
Accuracy, Solid State Band Gap ±0.9°F at 77°F (±0.3°C at 25°C)
Hysteresis ±1%
Repeatability ±0.1% typical
Temperature Limits -40 to 140°F (-40 to 60°C)
Storage Temperature -40 to 176°F (-40 to 80°C)
Compensated Temperature Range -4 to 140°F (-20 to 60°C)
Power Requirements 4-20 mA loop powered models 10 to 35 VDC; 0 to 5/10 V output models 15 to 35 VDC or 15 to 29 VAC
Output Signal (Model Dependent) 4 to 20 mA; 0 to 5/10 V at 5 mA max
Solid State Band Gap Temp Sensor Output Ranges Switch selectable, -20 to 140°F (-28.9 to 60°C)
0 to 100°F (-17.8 to 37.8°C)
40 to 90°F (4.4 to 32.3°C)
-4 to 140°F (-20 to 60°C)
Response Time 15 seconds
Electrical Connections Removable screw terminal block
Conduit Connection Duct Mount 1/2" NPS; OSA 1/2" (22.3 mm)
Drift <1% RH/year
RH Sensor Capacitance polymer
Temperature Sensor Types 1, 2, 3 solid state band gap;
Curves A,B,C; Thermistor; Curves D,E; Platinum RTD DIN 385
Enclosure Material Duct mount sensor tube PVC-UL 94 V-0
Duct mount sensor cap Polycarbonate ABS blend-greater than UL 94 V-0
Duct mount electronics housing and cover Makrolon® polycarbonate-UL 94V-HB
OSA Polycarbonate
Enclosure Rating Duct mount NEMA 4X (IP66) for housing only; OSA NEMA 4X (IP66)
Display Duct mount only, optional 2-line alpha numeric, 8 characters/line
Display Resolution RH 0.1%; 0.1°F (0.1°C)
Agency Approvals CE
Zero and Span Adjustments Menu scalable within the range.
Weight Duct Mount 0.616 lb (0.3 kg)
OSA 1 lb (0.45 kg)

What's included with the Dwyer RHP-2O1B

  • Dwyer RHP-2O1B RHP Series Humidity/Temperature Transmitter, OSA-mount, 2% RH

Ask a question about Dwyer RHP-2O1B RHP Series Humidity/Temperature Transmitter, OSA-mount, 2% RH

Customer Reviews for the Dwyer RHP-2O1B

Dwyer RHP-2O1B Offers

Reduce the long-term effects of condensation, fog, or high humidity with this transmitter that combines the voltage or current humidity transmitter output with a 10K type II NTC passive temperature thermistor output.

Features

  • Reduced installation cost with combined humidity and temperature
  • Wide application environment from a large selection of temperature sensors and 2%, 3% and 5% accuracies
  • Reduced system operating costs with radiation shield protecting the sensor from radiant heat

Applications

  • Air economizers
  • Outdoor temperature and relative humidity reference for building systems

Dwyer RHP-2O1B Specifications

Relative Humidity Range 0 to 100% RH
Temperature Range -40 to 140°F (-40 to 60°C)
Accuracy, RH ±2% 10 to 90% RH at 25°C
Accuracy, Thermistor Temp Sensor ±0.2°C at 25°C (±0.36°F at 77°F)
Accuracy, RTD Temp Sensor DIN Class B; ±0.3°C at 0°C (±0.54°F at 32°F)
Accuracy, Solid State Band Gap ±0.9°F at 77°F (±0.3°C at 25°C)
Hysteresis ±1%
Repeatability ±0.1% typical
Temperature Limits -40 to 140°F (-40 to 60°C)
Storage Temperature -40 to 176°F (-40 to 80°C)
Compensated Temperature Range -4 to 140°F (-20 to 60°C)
Power Requirements 4-20 mA loop powered models 10 to 35 VDC; 0 to 5/10 V output models 15 to 35 VDC or 15 to 29 VAC
Output Signal (Model Dependent) 4 to 20 mA; 0 to 5/10 V at 5 mA max
Solid State Band Gap Temp Sensor Output Ranges Switch selectable, -20 to 140°F (-28.9 to 60°C)
0 to 100°F (-17.8 to 37.8°C)
40 to 90°F (4.4 to 32.3°C)
-4 to 140°F (-20 to 60°C)
Response Time 15 seconds
Electrical Connections Removable screw terminal block
Conduit Connection Duct Mount 1/2" NPS; OSA 1/2" (22.3 mm)
Drift <1% RH/year
RH Sensor Capacitance polymer
Temperature Sensor Types 1, 2, 3 solid state band gap;
Curves A,B,C; Thermistor; Curves D,E; Platinum RTD DIN 385
Enclosure Material Duct mount sensor tube PVC-UL 94 V-0
Duct mount sensor cap Polycarbonate ABS blend-greater than UL 94 V-0
Duct mount electronics housing and cover Makrolon® polycarbonate-UL 94V-HB
OSA Polycarbonate
Enclosure Rating Duct mount NEMA 4X (IP66) for housing only; OSA NEMA 4X (IP66)
Display Duct mount only, optional 2-line alpha numeric, 8 characters/line
Display Resolution RH 0.1%; 0.1°F (0.1°C)
Agency Approvals CE
Zero and Span Adjustments Menu scalable within the range.
Weight Duct Mount 0.616 lb (0.3 kg)
OSA 1 lb (0.45 kg)

What's included with the Dwyer RHP-2O1B

  • Dwyer RHP-2O1B RHP Series Humidity/Temperature Transmitter, OSA-mount, 2% RH

Ask a question about Dwyer RHP-2O1B RHP Series Humidity/Temperature Transmitter, OSA-mount, 2% RH

Customer Reviews for the Dwyer RHP-2O1B

More Dwyer Products

Calibration Lab