Eurotherm WV468-2000.V1 DC Powered AC Voltage/Current Input Isolating Signal Conditioner, 50 V, 100 mA

Model: WV468-2000.V1

Eurotherm WV468-2000.V1 DC Powered AC Voltage/Current Input Isolating Signal Conditioner, 50 V, 100 mA

Model: WV468-2000.V1

Eliminate wasted power with this DC-powered AC voltage/current input-isolating signal conditioner featuring SmartPower to control its output supply. In addition, this alarm features eight AC voltage input ranges and two AC current input ranges.

Eliminate wasted power with this DC-powered AC voltage/current input-isolating signal conditioner featuring SmartPower to control its output supply. In addition, this alarm features eight AC voltage input ranges and two AC current input ranges.

Your Price $637.00 USD
Availability 13 in Stock
Quantity

Eurotherm WV468-2000.V1 Offers

Accurate and stable, this DC-powered AC voltage/current input-isolating signal conditioner is a high-accuracy signal conditioner with an isolated, DC voltage or current output. In addition, this conditioner features removable terminals for easy service.

Features

  • True RMS output
  • Lower power requirements with SmartPower
  • Improved accuracy
  • Bussed power with plug-in power clips
  • Removable terminals for easy service
  • Touch cal for best stability and accuracy
  • DIP switch configuration

Smart Power

This signal conditioner uses Smart Power to control its output supply. Smart Power automatically adjusts the voltage to drive the output loop to the required current. A low impedance current loop will subsequently require less voltage than a loop with higher impedance. Previous designs provided only a single supply at the highest voltage required to drive the highest impedance load. Using Smart Power results in power savings and reduces the operating temperature of the signal conditioner.

Enhanced LED diagnostics

Other than when executing the pushbutton calibration routine, the LEDs blink under the following conditions:

  • Green: Flashes at 2 Hz when the input is under range; flashes at 8 Hz when the input is over range
  • Red: Flashes at 2 Hz when the output is under range; flashes at 8 Hz when the output is over range
  • An Under Range condition exists when the signal is lower than the operational low value minus 6.25% of the operational span. An Over Range condition exists when the signal is higher than the operational high value plus 6.25% of the operational span. A voltage output short circuit may cause an under range condition (RED blinking at 2 Hz rate). A current output open circuit may cause an over range condition (RED blinking at an 8 Hz rate). There could be two or more LEDs blinking at the same time, which means the module has more than one error condition. Only when all error conditions have been removed, will the LEDs be back to normal (Green ON, Red and Yellow Off).

    Eurotherm WV468-2000.V1 Specifications

    Inputs Voltage ranges:
    50 mV, 150 mV, 500 mV, 5 V, 20 V, 50 V, 150 V, 250 V at ±0.15% of FS accuracy
    Impedance: >100 kΩ
    Over-voltage: 275 Vrms

    Current ranges:
    20 mA, 100 mA at ±0.15% of FS accuracy
    Impedance: 10 Ω typical
    Over-current: 200 mA, protected by self-resetting fuse
    Over-voltage: 60 V
    Frequency range: 40 to 400 Hz
    Linearity ±0.1% of span, typical
    Input Ranges Pushbutton adjustable
    Effective zero offset: >95%
    Effective span turndown: >95%
    Turn-Up/Turn-Down 80% (90% to ±0.25%)
    Output Ranges: 0 to 10 V DC; 0 to 20 mA, 4 to 20 mA
    Accuracy: ±0.05% of full scale
    Ripple: 0.2% of span, or 5 mVrms, whichever is greater

    Impedance:
    Voltage output: <10 Ω (source impedance)
    Current output: >100 kΩ

    Drive:
    Voltage output: 10 mA, maximum
    Current output: 20 V compliance at 20 mA (1 kΩ maximum)
    Response Time 100 ms typical
    Stability ±100 ppm of span/°C
    Common Mode Rejection 60 Hz: >90 dB; DC: >120 dB
    Temperature Operating: 32 to 140°F (0 to 60°C)
    Storage: -4 to 185°F (-20 to 85°C)
    Isolation, Input to Output to Power 1800 V DC
    Host Module Interface IR Link
    Agency Approvals (EMC and Safety) UL recognized per standard UL508 (File No.E99775)
    CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC (Input <75 V DC, only)
    RoHS compliant
    Power 9 to 30 V DC; 1 W typical, 2 W maximum
    Dimensions 4.39 x 3.54 x 0.5" (111.6 x 90 x 12.7 mm)
    DIN rail case
    Click here for complete specifications on the Eurotherm WV468-2000.V1

    What's included with the Eurotherm WV468-2000.V1

    • Eurotherm WV468-2000.V1 DC Powered AC Voltage/Current Input Isolating Signal Conditioner, 50 V, 100 mA

    Click on a category to view a selection of compatible accessories with the Eurotherm WV468-2000.V1 DC Powered AC Voltage/Current Input Isolating Signal Conditioner, 50 V, 100 mA.

    Eurotherm H910-0024 DIN-Rail Mount Power Supply, 1000 mA at 24 V DC, 115 to 230 V AC H910-0024
    Ideal for use with 24 V DC-powered products, this DIN-rail mount power supply supplies up to 1000 mA at 24 V DC. In addition, this power supply features an LED power indicator, input fuse protection, and output DC short circuit protection.




    Eurotherm H915-0001-1 DIN-Rail Mount Power Supply, 2300 mA at 24 V DC, 85 to 265 V AC H915-0001-1
    Ideal for use with 24 V DC-powered products, this DIN-rail mount power supply supplies up to 2300 mA at 24 V DC and has multiple wire terminal connections. In addition, this power supply features an LED power indicator, input fuse protection, and output DC short circuit protection.




    Eurotherm MB03-0000 End Bracket for the MD03 MB03-0000
    Compatible with the MD03 DIN rail, this end bracket is an accessory or replacement part.




    Eurotherm MD03-0000 TS35 x 7.5 DIN Rail, 6.56' MD03-0000
    Compatible with WV series signal conditioners, isolators, alarms, and power supplies, this TS35 x 7.5 DIN Rail is an accessory or replacement part. In addition, this rail features a length of 6.56' (2 m).




    Ask a question about Eurotherm WV468-2000.V1 DC Powered AC Voltage/Current Input Isolating Signal Conditioner, 50 V, 100 mA

    Customer Reviews for the Eurotherm WV468-2000.V1

    Eurotherm WV468-2000.V1 Offers

    Accurate and stable, this DC-powered AC voltage/current input-isolating signal conditioner is a high-accuracy signal conditioner with an isolated, DC voltage or current output. In addition, this conditioner features removable terminals for easy service.

    Features

    • True RMS output
    • Lower power requirements with SmartPower
    • Improved accuracy
    • Bussed power with plug-in power clips
    • Removable terminals for easy service
    • Touch cal for best stability and accuracy
    • DIP switch configuration

    Smart Power

    This signal conditioner uses Smart Power to control its output supply. Smart Power automatically adjusts the voltage to drive the output loop to the required current. A low impedance current loop will subsequently require less voltage than a loop with higher impedance. Previous designs provided only a single supply at the highest voltage required to drive the highest impedance load. Using Smart Power results in power savings and reduces the operating temperature of the signal conditioner.

    Enhanced LED diagnostics

    Other than when executing the pushbutton calibration routine, the LEDs blink under the following conditions:

  • Green: Flashes at 2 Hz when the input is under range; flashes at 8 Hz when the input is over range
  • Red: Flashes at 2 Hz when the output is under range; flashes at 8 Hz when the output is over range
  • An Under Range condition exists when the signal is lower than the operational low value minus 6.25% of the operational span. An Over Range condition exists when the signal is higher than the operational high value plus 6.25% of the operational span. A voltage output short circuit may cause an under range condition (RED blinking at 2 Hz rate). A current output open circuit may cause an over range condition (RED blinking at an 8 Hz rate). There could be two or more LEDs blinking at the same time, which means the module has more than one error condition. Only when all error conditions have been removed, will the LEDs be back to normal (Green ON, Red and Yellow Off).

    Eurotherm WV468-2000.V1 Specifications

    Inputs Voltage ranges:
    50 mV, 150 mV, 500 mV, 5 V, 20 V, 50 V, 150 V, 250 V at ±0.15% of FS accuracy
    Impedance: >100 kΩ
    Over-voltage: 275 Vrms

    Current ranges:
    20 mA, 100 mA at ±0.15% of FS accuracy
    Impedance: 10 Ω typical
    Over-current: 200 mA, protected by self-resetting fuse
    Over-voltage: 60 V
    Frequency range: 40 to 400 Hz
    Linearity ±0.1% of span, typical
    Input Ranges Pushbutton adjustable
    Effective zero offset: >95%
    Effective span turndown: >95%
    Turn-Up/Turn-Down 80% (90% to ±0.25%)
    Output Ranges: 0 to 10 V DC; 0 to 20 mA, 4 to 20 mA
    Accuracy: ±0.05% of full scale
    Ripple: 0.2% of span, or 5 mVrms, whichever is greater

    Impedance:
    Voltage output: <10 Ω (source impedance)
    Current output: >100 kΩ

    Drive:
    Voltage output: 10 mA, maximum
    Current output: 20 V compliance at 20 mA (1 kΩ maximum)
    Response Time 100 ms typical
    Stability ±100 ppm of span/°C
    Common Mode Rejection 60 Hz: >90 dB; DC: >120 dB
    Temperature Operating: 32 to 140°F (0 to 60°C)
    Storage: -4 to 185°F (-20 to 85°C)
    Isolation, Input to Output to Power 1800 V DC
    Host Module Interface IR Link
    Agency Approvals (EMC and Safety) UL recognized per standard UL508 (File No.E99775)
    CE conformance per EMC directive 2004/108/EC and low voltage directive 2006/95/EC (Input <75 V DC, only)
    RoHS compliant
    Power 9 to 30 V DC; 1 W typical, 2 W maximum
    Dimensions 4.39 x 3.54 x 0.5" (111.6 x 90 x 12.7 mm)
    DIN rail case
    Click here for complete specifications on the Eurotherm WV468-2000.V1

    What's included with the Eurotherm WV468-2000.V1

    • Eurotherm WV468-2000.V1 DC Powered AC Voltage/Current Input Isolating Signal Conditioner, 50 V, 100 mA

    Click on a category to view a selection of compatible accessories with the Eurotherm WV468-2000.V1 DC Powered AC Voltage/Current Input Isolating Signal Conditioner, 50 V, 100 mA.

    Eurotherm H910-0024 DIN-Rail Mount Power Supply, 1000 mA at 24 V DC, 115 to 230 V AC H910-0024
    Ideal for use with 24 V DC-powered products, this DIN-rail mount power supply supplies up to 1000 mA at 24 V DC. In addition, this power supply features an LED power indicator, input fuse protection, and output DC short circuit protection.




    Eurotherm H915-0001-1 DIN-Rail Mount Power Supply, 2300 mA at 24 V DC, 85 to 265 V AC H915-0001-1
    Ideal for use with 24 V DC-powered products, this DIN-rail mount power supply supplies up to 2300 mA at 24 V DC and has multiple wire terminal connections. In addition, this power supply features an LED power indicator, input fuse protection, and output DC short circuit protection.




    Eurotherm MB03-0000 End Bracket for the MD03 MB03-0000
    Compatible with the MD03 DIN rail, this end bracket is an accessory or replacement part.




    Eurotherm MD03-0000 TS35 x 7.5 DIN Rail, 6.56' MD03-0000
    Compatible with WV series signal conditioners, isolators, alarms, and power supplies, this TS35 x 7.5 DIN Rail is an accessory or replacement part. In addition, this rail features a length of 6.56' (2 m).




    Ask a question about Eurotherm WV468-2000.V1 DC Powered AC Voltage/Current Input Isolating Signal Conditioner, 50 V, 100 mA

    Customer Reviews for the Eurotherm WV468-2000.V1

    More Eurotherm Products

    Calibration Lab