Extech 382097 Current Clamp Probes, 100A

Model: 382097 | UPC: 793950382974

Extech 382097 Current Clamp Probes, 100A

Model: 382097 | UPC: 793950382974

Set of 3 Current Clamp Probes for use with the Extech 382098 Flexible Current Clamp Probes.

Set of 3 Current Clamp Probes for use with the Extech 382098 Flexible Current Clamp Probes.

Your Price $509.00 USD
Availability 1 to 2 Weeks
Quantity

Extech 382097 Offers

Features

  • Large backlighting LCD displays up to 35 parameters in one screen (3P4W)
  • Clamp-on True RMS power measurements with on-screen Harmonics display (1-99th order)
  • Simultaneous display of Harmonics and Waveform
  • Display of Waveform with Peak Values (1024 samples/period)
  • Analysis of Total Harmonic Distortion (THD-F)
  • Displays Active Power (kW), Apparent Power (kVA), Reactive Power (kVAR) and Power Factor
  • kWH and kVARh energy measurements
  • Maximum demand (MDkW, MW, kVA, MVA) with programmable period
  • Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000)
  • Graphic Phase diagram with 3-Phase system parameters
  • 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%)
  • Calculated Unbalanced Current through Neutral Line (In)
  • Data-logger records up to 52428 records in single phase, (17476 records in 3-phase)
  • Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%)
  • Optically isolated RS-232 interface with software to download Waveforms, Power Parameters and Harmonics

Extech 382097 Specifications

ACV (True rms) Range: 600 V
Basic Accuracy: ±(0.5%rdg+5d)
ACA Range: 1000 A
Basic Accuracy: ±(0.5%rdg+5d)
Active Power (kW) Range: 9.999 MW
Basic Accuracy: ±(1%rdg+8d)
Apparent Power (kVA) Range: 9999 kVA
Basic Accuracy: VA=Vrms x Arms
Reactive Power (kVAR) Range: 9999 kVAR
Basic Accuracy: VAR=sqr (VA²-W²)
Power Factor Range: 0.0 to +1.00
Basic Accuracy: ±(1.5%°rdg±8d)
Frequency Range: 45 to 65 Hz
Basic Accuracy: 0.1 Hz
Phase Range: -180° to 0° to 180°
Basic Accuracy: ±°
Harmonics Range: 1 to 99
Basic Accuracy: ±2%
Crest Factor Range: 1 to 99
Basic Accuracy: ±(5%+30d)
Peak AC Voltage accuracy Basic Accuracy:±(5%rdg+30d)
Peak AC Current accuracy Basic Accuracy: ±(5%rdg+30d)
Active Power Energy (kWh) Range: 0 mWh to 999,999 kWh
Reactive Power Energy (kVARh) Range: 0.0 kVARh to 1000 MWh
Data-Logging Range: 52428 records (single phase)/17476 records (3 phase)
Dimensions 10.1 x 6.1 x 2.3" (257 x 155 x 57 mm)
Weight Meter: 2.5 lbs. (1160 g)
Clamp: 1.3 lbs. (600 g)
Click here for complete specifications on the Extech 382097

What's included with the Extech 382097

  • Extech 382097 Current Clamp Probes, 100A

Ask a question about Extech 382097 Current Clamp Probes, 100A

Customer Reviews for the Extech 382097

Extech 382097 Offers

Features

  • Large backlighting LCD displays up to 35 parameters in one screen (3P4W)
  • Clamp-on True RMS power measurements with on-screen Harmonics display (1-99th order)
  • Simultaneous display of Harmonics and Waveform
  • Display of Waveform with Peak Values (1024 samples/period)
  • Analysis of Total Harmonic Distortion (THD-F)
  • Displays Active Power (kW), Apparent Power (kVA), Reactive Power (kVAR) and Power Factor
  • kWH and kVARh energy measurements
  • Maximum demand (MDkW, MW, kVA, MVA) with programmable period
  • Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000)
  • Graphic Phase diagram with 3-Phase system parameters
  • 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%)
  • Calculated Unbalanced Current through Neutral Line (In)
  • Data-logger records up to 52428 records in single phase, (17476 records in 3-phase)
  • Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%)
  • Optically isolated RS-232 interface with software to download Waveforms, Power Parameters and Harmonics

Extech 382097 Specifications

ACV (True rms) Range: 600 V
Basic Accuracy: ±(0.5%rdg+5d)
ACA Range: 1000 A
Basic Accuracy: ±(0.5%rdg+5d)
Active Power (kW) Range: 9.999 MW
Basic Accuracy: ±(1%rdg+8d)
Apparent Power (kVA) Range: 9999 kVA
Basic Accuracy: VA=Vrms x Arms
Reactive Power (kVAR) Range: 9999 kVAR
Basic Accuracy: VAR=sqr (VA²-W²)
Power Factor Range: 0.0 to +1.00
Basic Accuracy: ±(1.5%°rdg±8d)
Frequency Range: 45 to 65 Hz
Basic Accuracy: 0.1 Hz
Phase Range: -180° to 0° to 180°
Basic Accuracy: ±°
Harmonics Range: 1 to 99
Basic Accuracy: ±2%
Crest Factor Range: 1 to 99
Basic Accuracy: ±(5%+30d)
Peak AC Voltage accuracy Basic Accuracy:±(5%rdg+30d)
Peak AC Current accuracy Basic Accuracy: ±(5%rdg+30d)
Active Power Energy (kWh) Range: 0 mWh to 999,999 kWh
Reactive Power Energy (kVARh) Range: 0.0 kVARh to 1000 MWh
Data-Logging Range: 52428 records (single phase)/17476 records (3 phase)
Dimensions 10.1 x 6.1 x 2.3" (257 x 155 x 57 mm)
Weight Meter: 2.5 lbs. (1160 g)
Clamp: 1.3 lbs. (600 g)
Click here for complete specifications on the Extech 382097

What's included with the Extech 382097

  • Extech 382097 Current Clamp Probes, 100A

Ask a question about Extech 382097 Current Clamp Probes, 100A

Customer Reviews for the Extech 382097

More Extech Products

Calibration Lab