Extech EX623A True RMS AC/DC Clamp Meter with IR thermometer and NCV, 0.01 to 600 A

Model: EX623A

Extech EX623A True RMS AC/DC Clamp Meter with IR thermometer and NCV, 0.01 to 600 A

Model: EX623A

Excellent solution for testing requirements, this True RMS AC/DC clamp meter features dual thermocouple inputs for T1, T2, and T1-T2 differential temperature measurement, being an ideal all-in-one solution for accurate readings. In addition, it includes a built-in infrared thermometer and laser pointer for pinpointing hot spots.

Excellent solution for testing requirements, this True RMS AC/DC clamp meter features dual thermocouple inputs for T1, T2, and T1-T2 differential temperature measurement, being an ideal all-in-one solution for accurate readings. In addition, it includes a built-in infrared thermometer and laser pointer for pinpointing hot spots.

Your Price $229.99 USD
Availability 1 to 2 Weeks
Quantity

Extech EX623A Offers

The EX623A features a Non-Contact Voltage (NCV) detector, which adds a layer of safety. Its DC micro-amp function is ideal for flame rod measurements in HVAC/R systems, and its capacitance measurement capability extends up to 40 mF.

Comes complete with test leads, a 9 V battery, two type K bead wire temperature probes, and a carrying case.

Features

  • True RMS for accurate measurements of AC voltage and current measures
  • All-in-one HVAC/R meter
  • Combines the functionality of a 600 A AC/DC clamp meter with a built-in infrared thermometer
  • Dual type K thermometer with differential temperature function (T1, T2, T1-T2)
  • Non-Contact Voltage (NCV) detection enhances safety while measuring electrical installations
  • Perform safe and accurate inspections
  • AC/DC μA multimeter function specifically designed for HVAC/R flame rod current measurements and capacitance measurement up to 40 mF
  • Multimeter functions for DC voltage, resistance, capacitance, and frequency
  • LoZ mode prevents false readings due to ghost voltages
  • Low Pass Filter (LPF) ensures accurate measurements in electrically noisy environments
  • 1.25" (32 mm) jaw opening for conductors up to 500 MCM
  • 6000 count backlit LCD display
  • Rugged double molded housing
  • Auto power off with audible alert and disable function
  • Autoranging with manual override

Applications

  • HVAC/R systems
  • Energy
  • Electrical inspections
  • Electrical troubleshooting and maintenance
  • Building facilities
  • Facilities maintenance
  • Commercial
  • Residential
  • Hospital
  • Universities

Extech EX623A Specifications

Type AC/DC
True RMS Yes
Display Counts 6000
Current AC: 0.01 to 600 A
DC: 0.01 to 600 A
Basic ACA accuracy: ±(1.5% + 5d)
Voltage AC: 0.1 mv to 600 V
DC: 0.1 mv to 600 V
µa Current 0.1 to 600 μA
Resistance 0.1 Ω to 60 MΩ
Capacitance 0.001 nF to 40 mF
Frequency 0.001 Hz to 100 kHz
Clamp: 0.1 to 400 Hz
Duty Cycle 0.5 to 99.0%
Temperature Type K: -58 to 1832°F (-50 to 1000°C)
Infrared: -58 to 518°F (-50 to 270°C)
Operating: 32 to 122°F (0 to 50°C)
Distance to Spot Ratio 8:1
NCV Detector Yes
Peak Hold Yes
Inrush (100 ms) Yes
LoZ Yes
Low Pass Filter Yes
Safety Category CAT III-600 V
Dimensions 9.4 x 3.7 x 1.74" (241 x 96 x 45 mm)
Jaw size: 1.25" (32 mm)
Weight 11.11 oz (315 g)
Click here for complete specifications on the Extech EX623A

What's included with the Extech EX623A

  • Clamp Meter
  • Double-molded Test Leads
  • Dual Type K Bead Wire Temperature Probe
  • Pouch
  • Carrying Case
  • 9 V Battery
  • User Manual
  • Two-Year Warranty

Ask a question about Extech EX623A True RMS AC/DC Clamp Meter with IR thermometer and NCV, 0.01 to 600 A

Customer Reviews for the Extech EX623A

Extech EX623A Offers

The EX623A features a Non-Contact Voltage (NCV) detector, which adds a layer of safety. Its DC micro-amp function is ideal for flame rod measurements in HVAC/R systems, and its capacitance measurement capability extends up to 40 mF.

Comes complete with test leads, a 9 V battery, two type K bead wire temperature probes, and a carrying case.

Features

  • True RMS for accurate measurements of AC voltage and current measures
  • All-in-one HVAC/R meter
  • Combines the functionality of a 600 A AC/DC clamp meter with a built-in infrared thermometer
  • Dual type K thermometer with differential temperature function (T1, T2, T1-T2)
  • Non-Contact Voltage (NCV) detection enhances safety while measuring electrical installations
  • Perform safe and accurate inspections
  • AC/DC μA multimeter function specifically designed for HVAC/R flame rod current measurements and capacitance measurement up to 40 mF
  • Multimeter functions for DC voltage, resistance, capacitance, and frequency
  • LoZ mode prevents false readings due to ghost voltages
  • Low Pass Filter (LPF) ensures accurate measurements in electrically noisy environments
  • 1.25" (32 mm) jaw opening for conductors up to 500 MCM
  • 6000 count backlit LCD display
  • Rugged double molded housing
  • Auto power off with audible alert and disable function
  • Autoranging with manual override

Applications

  • HVAC/R systems
  • Energy
  • Electrical inspections
  • Electrical troubleshooting and maintenance
  • Building facilities
  • Facilities maintenance
  • Commercial
  • Residential
  • Hospital
  • Universities

Extech EX623A Specifications

Type AC/DC
True RMS Yes
Display Counts 6000
Current AC: 0.01 to 600 A
DC: 0.01 to 600 A
Basic ACA accuracy: ±(1.5% + 5d)
Voltage AC: 0.1 mv to 600 V
DC: 0.1 mv to 600 V
µa Current 0.1 to 600 μA
Resistance 0.1 Ω to 60 MΩ
Capacitance 0.001 nF to 40 mF
Frequency 0.001 Hz to 100 kHz
Clamp: 0.1 to 400 Hz
Duty Cycle 0.5 to 99.0%
Temperature Type K: -58 to 1832°F (-50 to 1000°C)
Infrared: -58 to 518°F (-50 to 270°C)
Operating: 32 to 122°F (0 to 50°C)
Distance to Spot Ratio 8:1
NCV Detector Yes
Peak Hold Yes
Inrush (100 ms) Yes
LoZ Yes
Low Pass Filter Yes
Safety Category CAT III-600 V
Dimensions 9.4 x 3.7 x 1.74" (241 x 96 x 45 mm)
Jaw size: 1.25" (32 mm)
Weight 11.11 oz (315 g)
Click here for complete specifications on the Extech EX623A

What's included with the Extech EX623A

  • Clamp Meter
  • Double-molded Test Leads
  • Dual Type K Bead Wire Temperature Probe
  • Pouch
  • Carrying Case
  • 9 V Battery
  • User Manual
  • Two-Year Warranty

Ask a question about Extech EX623A True RMS AC/DC Clamp Meter with IR thermometer and NCV, 0.01 to 600 A

Customer Reviews for the Extech EX623A

More Extech Products

Calibration Lab