Measures, graphs, and records PRTs thermocouples, and thermistors, making this reference thermometer ideal for field applications, laboratory measurements, and data logging. Also, it provides high accuracy, a wide measurement range, logging, trending, and comes equipped with a magnetic meter hanger and connectors.
Measures, graphs, and records PRTs thermocouples, and thermistors, making this reference thermometer ideal for field applications, laboratory measurements, and data logging. Also, it provides high accuracy, a wide measurement range, logging, trending, and comes equipped with a magnetic meter hanger and connectors.
Measure, graph and record three sensor types with one tool.
Features
Applications
Input Channels | 1 |
Resolution | PRTs and thermistors: 0.001° Thermocouples: 0.01° |
Logging | 25 readings with statistics |
Sample Interval (Normal) | 1 second |
Typical Sample Interval (Fast Mode) | 0.3 seconds |
Sensor Types | PRTs, RTDs, thermistors, and thermocouples |
Thermocouple Types | C, E, J, K, L, M, N, T, U, B, R, S |
Statistics | Maximum, minimum, average, standard deviation |
Trending | Scale: ±18°F (10°C), ±1.8°F (1°C), ±0.18°F (0.1°C), ±0.018°F (0.01°C), 10 minutes of real-time data |
Power Requirements | 3 x AA alkaline batteries, 12 V dc universal power supply |
Computer Interface | RS-232, 9940 I/O ToolKit software included |
Environmental Conditions for Best Accuracy | 55.4 to 91.4°F (13 to 33°C) |
Millivolt Range and Accuracy | 10 to 75 mV, ± (0.005% + 5 µV) |
Internal Reference Junction Compensation | ±0.36°F (±0.2°C) |
Resistance Range and Accuracy | 0 to 400 Ω ± (0.004% + 0.002 Ω) 200 Ω to 50 kΩ ± (0.01% + 0.5 Ω) 50 to 500 kΩ ± (0.03 %) |
Temperature Coefficient, Voltage | ±(0.001%/°C + 1 mV/°C) |
Temperature Coefficient, Resistance | 0.0008%/°C + 0.0004 Ω (0 to 400 Ω) 0.002%/°C + 0.1 Ω (0 Ω to 50 kΩ) 0.06%/°C + 0.1 Ω (50 to 500 kΩ) |
Excitation Current, Resistance | 1 mA (0 to 400 Ω) 10 µA (0 Ω to 50 kΩ) 2 µA (50 to 500 kΩ) |
Dimensions | 3.75 x 7.9 x 1.86" (96 x 200 x 47 mm) |
Weight | 1.45 lbs (0.65 kg) |
Safety | EN61010-1:2001, CAN/CSA C22.2 No. 61010.1-04 |
Click on a category to view a selection of compatible accessories with the Fluke 1523-P4 Reference (IR) Thermometer Kit with carrying case.
Input Channels | 1 |
Resolution | PRTs and thermistors: 0.001° Thermocouples: 0.01° |
Logging | 25 readings with statistics |
Sample Interval (Normal) | 1 second |
Typical Sample Interval (Fast Mode) | 0.3 seconds |
Sensor Types | PRTs, RTDs, thermistors, and thermocouples |
Thermocouple Types | C, E, J, K, L, M, N, T, U, B, R, S |
Statistics | Maximum, minimum, average, standard deviation |
Trending | Scale: ±18°F (10°C), ±1.8°F (1°C), ±0.18°F (0.1°C), ±0.018°F (0.01°C), 10 minutes of real-time data |
Power Requirements | 3 x AA alkaline batteries, 12 V dc universal power supply |
Computer Interface | RS-232, 9940 I/O ToolKit software included |
Environmental Conditions for Best Accuracy | 55.4 to 91.4°F (13 to 33°C) |
Millivolt Range and Accuracy | 10 to 75 mV, ± (0.005% + 5 µV) |
Internal Reference Junction Compensation | ±0.36°F (±0.2°C) |
Resistance Range and Accuracy | 0 to 400 Ω ± (0.004% + 0.002 Ω) 200 Ω to 50 kΩ ± (0.01% + 0.5 Ω) 50 to 500 kΩ ± (0.03 %) |
Temperature Coefficient, Voltage | ±(0.001%/°C + 1 mV/°C) |
Temperature Coefficient, Resistance | 0.0008%/°C + 0.0004 Ω (0 to 400 Ω) 0.002%/°C + 0.1 Ω (0 Ω to 50 kΩ) 0.06%/°C + 0.1 Ω (50 to 500 kΩ) |
Excitation Current, Resistance | 1 mA (0 to 400 Ω) 10 µA (0 Ω to 50 kΩ) 2 µA (50 to 500 kΩ) |
Dimensions | 3.75 x 7.9 x 1.86" (96 x 200 x 47 mm) |
Weight | 1.45 lbs (0.65 kg) |
Safety | EN61010-1:2001, CAN/CSA C22.2 No. 61010.1-04 |
Click on a category to view a selection of compatible accessories with the Fluke 1523-P4 Reference (IR) Thermometer Kit with carrying case.