Run seven installation tests automatically in one sequence with a single connection with this installation multifunction tester which features an insulation pre-test to prevent damage to connected appliances. In addition, this tester allows wireless transmission and viewing of test results from the field on a smartphone.
Run seven installation tests automatically in one sequence with a single connection with this installation multifunction tester which features an insulation pre-test to prevent damage to connected appliances. In addition, this tester allows wireless transmission and viewing of test results from the field on a smartphone.
Verify the safety of electrical installations with this installation multifunction tester capable of ensuring that fixed wiring is safe and correctly installed to meet the requirements of IEC 60364. Additionally, this tester features cloud storage to save your test results and reduce transcription errors.
Features
Reduce test time up to 40% with auto test
Auto test does five required installation tests in one sequence, including selectable type A, AC and RCD auto test, ensuring compliance with local installation regulations. It reduces the number of manual connections, decreases the possibility of making errors and reduces test time up to 40% from previous models
Insulation pretest
Protect the installation. Avoid costly mistakes. The installation tester is the only installation with “insulation pretest," which warns you about potentially serious and costly mistakes. If the tester detects that appliances are connected to the system during test, it will stop the insulation test and provide a visual and audible warning. This helps eliminate accidental damage to peripheral equipment and keeps your customers happy.
Share from anywhere
Save time, eliminate data entry by wirelessly syncing measurements directly from your installation tester and share with your team. Having access to measurements simultaneous at the inspection site and from the office or an off-site location enables faster decision making and real time collaboration between team members.
Cloud storage
Retrieve stored results from anywhere. Cloud storage allows you to retrieve stored results whether you are in the office or in the field to make decisions in real time. Uses radio-enabled test tools and a mobile app to transfer measurements straight from the field to a secure cloud location, where the data can be accessed by team members. Plus you can import the data into DMS to process and generate certificates.
Applications
AC and DC Voltage Measurement Trms | Range: 500 V Resolution: 0.1 V Input impedance: 3.3 MΩ Overload protection: 660 V rms |
Continuity Testing (RLO) | Range (autoranging): 20 Ω/200 Ω/2000 Ω Resolution: 0.01 Ω/0.1 Ω/1 Ω Open circuit voltage: >4 V |
Insulation Resistance Measurement (RISO) | Test voltages: 50/100/250/500/1000 V Test voltage: 50 V, Insulation resistance range: 20 MΩ/50 MΩ, Test current: 1 mA at 50 kΩ Test voltage: 100 V, Insulation resistance range: 20 MΩ/100 MΩ, Test current: 1 mA at 100 kΩ Test voltage: 250 V, Insulation resistance range: 20 MΩ/200 MΩ, Test current: 1 mA at 250 kΩ Test voltage: 500 V, Insulation resistance range: 20 MΩ/200 MΩ/500 MΩ, Test current: 1 mA at 500 kΩ Test voltage: 1000 V, Insulation resistance range: 20 MΩ/200 MΩ/1000 MΩ, Test current: 1 mA at 1 MΩ |
Insulation Safety Pretest | Requires to connect the tester to L, N and PE |
Loop and Line Impedance (ZI) | Range: 10 Ω (Hi current mΩ mode)/20 Ω/200 Ω/2000 Ω Resolution: 1 mΩ/ 0.01 Ω/ 0.1 Ω/1Ω |
Prospective Earth Fault Current, PSC Test | Range: 1000 A/10 kA (50 kA) Resolution: 1 A/0.1 kA Computation: Prospective earth fault current (PEFC) or prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively |
RCD Testing, RCD Types Tested | RCD Type: AC (responds to AC) General, no delay Time delay Responds to pulsed signal Responds to smooth DC signal |
RCD Trip Time Test (ΔT) | Current Settings (1000 mA type AC only. 700 mA maximum type A in VAR mode, VAR mode not available for type B) 10/30/100/300/500/1000 mA – VAR 10/30/100 mA Multiplier: x½, x 1 Measurement range RCD type G: 310 ms 50 ms Measurement range RCD type S: 510 ms 160 ms |
RCD Trip Current Measurement/Ramp Test (I ΔN) | Current range: 30 to 110% of RCD rated current (30 to 150% for Type A IΔN >10 mA) Step size: 10% of IΔN (5% for Type B) Dwell time type G: 300 ms/step Dwell time type S: 500 ms/step Measurement Accuracy: ±5% Notes: 30 to 210% for Type A IΔN = 10mA, 20 to 210% for Type B Specified trip current ranges (EN 61008-1): 50 to 100% for Type AC 35 to 140% for Type A (>10 mA) 35 to 200% for Type A (≤10 mA) 50 to 20 % for Type B |
Earth Resistance Test (RE) | Range: 200 Ω/2000 Ω Resolution: 0.1 Ω/1 Ω Frequency: 128 Hz Output voltage: 25 V |
Phase Sequence Indicaton | Icon: Phase sequence indicator is active Range: 100 to 500 V Display: “1-2-3": or “3-2-1" |
Performance | EC/EN61557-1 to IEC/EN61557-7 and IEC/EN61557-10 |
Overvoltage | CAT III 500 V, CAT IV 300 V |
Safety | Complies with IEC/EN61010-1, UL61010, ANSI/ISA –s82.02.01 and CAN/CSA c22.2 No. 1010 |
Sealing | IP 40 |
Battery | 1.5 V type AA (IEC LR6), 6 pcs |
Dimensions | 3.93 x 9.84 x 4.92" (10 x 25 x 12.5 cm) |
Weight | Approximately 2.86 lbs (1.3 kg) including batteries |
Click on a category to view a selection of compatible accessories with the Fluke 1664FC US Installation Multifunction Tester, 500 V, insulation pre-test.
AC and DC Voltage Measurement Trms | Range: 500 V Resolution: 0.1 V Input impedance: 3.3 MΩ Overload protection: 660 V rms |
Continuity Testing (RLO) | Range (autoranging): 20 Ω/200 Ω/2000 Ω Resolution: 0.01 Ω/0.1 Ω/1 Ω Open circuit voltage: >4 V |
Insulation Resistance Measurement (RISO) | Test voltages: 50/100/250/500/1000 V Test voltage: 50 V, Insulation resistance range: 20 MΩ/50 MΩ, Test current: 1 mA at 50 kΩ Test voltage: 100 V, Insulation resistance range: 20 MΩ/100 MΩ, Test current: 1 mA at 100 kΩ Test voltage: 250 V, Insulation resistance range: 20 MΩ/200 MΩ, Test current: 1 mA at 250 kΩ Test voltage: 500 V, Insulation resistance range: 20 MΩ/200 MΩ/500 MΩ, Test current: 1 mA at 500 kΩ Test voltage: 1000 V, Insulation resistance range: 20 MΩ/200 MΩ/1000 MΩ, Test current: 1 mA at 1 MΩ |
Insulation Safety Pretest | Requires to connect the tester to L, N and PE |
Loop and Line Impedance (ZI) | Range: 10 Ω (Hi current mΩ mode)/20 Ω/200 Ω/2000 Ω Resolution: 1 mΩ/ 0.01 Ω/ 0.1 Ω/1Ω |
Prospective Earth Fault Current, PSC Test | Range: 1000 A/10 kA (50 kA) Resolution: 1 A/0.1 kA Computation: Prospective earth fault current (PEFC) or prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively |
RCD Testing, RCD Types Tested | RCD Type: AC (responds to AC) General, no delay Time delay Responds to pulsed signal Responds to smooth DC signal |
RCD Trip Time Test (ΔT) | Current Settings (1000 mA type AC only. 700 mA maximum type A in VAR mode, VAR mode not available for type B) 10/30/100/300/500/1000 mA – VAR 10/30/100 mA Multiplier: x½, x 1 Measurement range RCD type G: 310 ms 50 ms Measurement range RCD type S: 510 ms 160 ms |
RCD Trip Current Measurement/Ramp Test (I ΔN) | Current range: 30 to 110% of RCD rated current (30 to 150% for Type A IΔN >10 mA) Step size: 10% of IΔN (5% for Type B) Dwell time type G: 300 ms/step Dwell time type S: 500 ms/step Measurement Accuracy: ±5% Notes: 30 to 210% for Type A IΔN = 10mA, 20 to 210% for Type B Specified trip current ranges (EN 61008-1): 50 to 100% for Type AC 35 to 140% for Type A (>10 mA) 35 to 200% for Type A (≤10 mA) 50 to 20 % for Type B |
Earth Resistance Test (RE) | Range: 200 Ω/2000 Ω Resolution: 0.1 Ω/1 Ω Frequency: 128 Hz Output voltage: 25 V |
Phase Sequence Indicaton | Icon: Phase sequence indicator is active Range: 100 to 500 V Display: “1-2-3": or “3-2-1" |
Performance | EC/EN61557-1 to IEC/EN61557-7 and IEC/EN61557-10 |
Overvoltage | CAT III 500 V, CAT IV 300 V |
Safety | Complies with IEC/EN61010-1, UL61010, ANSI/ISA –s82.02.01 and CAN/CSA c22.2 No. 1010 |
Sealing | IP 40 |
Battery | 1.5 V type AA (IEC LR6), 6 pcs |
Dimensions | 3.93 x 9.84 x 4.92" (10 x 25 x 12.5 cm) |
Weight | Approximately 2.86 lbs (1.3 kg) including batteries |
Click on a category to view a selection of compatible accessories with the Fluke 1664FC US Installation Multifunction Tester, 500 V, insulation pre-test.