Offering outstanding flexibility, customize thresholds, algorithms, and measurement selections, this quality recorder has Class A compliance to IEC 61000 4 30 for the most demanding power quality tests. Captures the most minute details on user-selected parameters and allows for later analysis and reporting.
Offering outstanding flexibility, customize thresholds, algorithms, and measurement selections, this quality recorder has Class A compliance to IEC 61000 4 30 for the most demanding power quality tests. Captures the most minute details on user-selected parameters and allows for later analysis and reporting.
Ideal for analyzing utility and industrial power distribution systems, this power recorder captures the most comprehensive details on user-selected parameters.
Features
Applications
Fully Class-A compliant
The Three-Phase Power Quality Recorder is fully compliant with the new IEC 61000-4-30 Class-A standard, which defines the measurement methods required for each power parameter in order to obtain reliable, repeatable, and comparable results. With the GPS time synchronization accessory, data recorded with multiple instruments can be correlated with Class-A precision.
User-configurable operation
The versatile measurement algorithms and trigger settings allow the expert and general users to optimize the Three-Phase Power Quality Recorder for each application in order to capture exactly the data required. Data can be transferred to a computer directly, or via an Ethernet network and can be retrieved during recording without interrupting the measurements.
Rugged and reliable
The instrument, accessories, and power supply help you safely conduct tests with a 600 V CAT IV rating per EN 61010-1 conformity requirements. The Fluke 1760 features a double insulated enclosure, which helps protect the user, equipment, and surroundings from electrical shock. With a 2 GB compact flash memory instead of a hard disk, there are no rotating parts inside the instrument, increasing its reliability and durability for everyday use.
Broad measurement range
Developed in cooperation with power utilities, the EN50160 statistical analysis presents a summary of the quality of voltage against internationally defined limits. When a threshold is exceeded, the Three-Phase Power Quality Recorder automatically captures voltage and current waveform data on all phases simultaneously. Nearly every power quality and power parameter is measured, including rms values, flicker, voltage dips, voltage swells, voltage unbalance, current and voltage harmonics to the 50th, interharmonics, THD, mains signaling, reactive power, transients, and power factor.
Plug and play
The Fluke 1760 Power Quality Recorder features easy plug and play setup for immediate use. The current and voltage probes are plugged in separately to the instrument, which automatically detects, configures, and provides power to the probes. All accessories are individually calibrated and can be shared with multiple recorders.
PQ Analyze Software
The Fluke 1760 includes comprehensive software for detailed power quality analysis on Windows® based PCs. In the online mode, the software enables remote instrument setup, job processing, real-time verification of actual measurement values, and data download. Data can be viewed in trend diagrams for root cause analysis or in a variety of statistical summaries. You can also generate professional reports with the Report Writer function.
Measurement Inputs | |
Number of Inputs | 8 galvanically isolated inputs for voltage and current measurements |
Sensor Category Rating | Up to 600 V CAT IV depending on sensor |
Nominal Voltage (RMS) | 100 mV |
Overload Capacity (RMS) | 1000 V, continuously |
Power Supply | |
Range | AC: 83 to 264 V; 45 to 65 Hz DC : 100 to 375 V< |
Power Consumption | NIMH, 7.2 V, 2.7 Ah |
Battery Pack | In case of a power supply failure an internal battery maintains the supply for up to 40 minutes. Afterwards, or in case of discharged battery the Fluke 1760 is turned off and continues the measurements with the latest settings as soon as the supply voltage returns. The battery can be replaced by the user. |
General Specifications | |
Warranty | Two Years |
Data Memory | 2 GB Flash Memory |
Interfaces | Ethernet (100 MB/s), compatible to Windows® 98/ME/NT/2000/XP RS 232, external modem via RS 232 |
Dimensions | 13 x 11.8 x 2.6" (325 x 300 x 65 mm) |
Weight | Approx. 10.8 lb (4.9 kg) |
Click on a category to view a selection of compatible accessories with the Fluke 1760 TR US Three-Phase Power Quality Recorder with Trans Topas.
Measurement Inputs | |
Number of Inputs | 8 galvanically isolated inputs for voltage and current measurements |
Sensor Category Rating | Up to 600 V CAT IV depending on sensor |
Nominal Voltage (RMS) | 100 mV |
Overload Capacity (RMS) | 1000 V, continuously |
Power Supply | |
Range | AC: 83 to 264 V; 45 to 65 Hz DC : 100 to 375 V< |
Power Consumption | NIMH, 7.2 V, 2.7 Ah |
Battery Pack | In case of a power supply failure an internal battery maintains the supply for up to 40 minutes. Afterwards, or in case of discharged battery the Fluke 1760 is turned off and continues the measurements with the latest settings as soon as the supply voltage returns. The battery can be replaced by the user. |
General Specifications | |
Warranty | Two Years |
Data Memory | 2 GB Flash Memory |
Interfaces | Ethernet (100 MB/s), compatible to Windows® 98/ME/NT/2000/XP RS 232, external modem via RS 232 |
Dimensions | 13 x 11.8 x 2.6" (325 x 300 x 65 mm) |
Weight | Approx. 10.8 lb (4.9 kg) |