Fluke 3000 FC General Maintenance Kit

Model: 3000 FC General Maintenance Kit | Order No: 3000FC-GM | UPC: 095969724562

Fluke 3000 FC General Maintenance Kit

Model: 3000 FC General Maintenance Kit | Order No: 3000FC-GM | UPC: 095969724562

The Fluke Connect General Maintenance Kit includes the 3000 FC Multimeter, iflex clamp module, AC voltage module, DC voltage module, and accessories.

The Fluke Connect General Maintenance Kit includes the 3000 FC Multimeter, iflex clamp module, AC voltage module, DC voltage module, and accessories.

Your Price $1129.99 USD
Availability 12 to 13 Weeks
Quantity

Traceable In-House Calibration Certificate for your A3001FC

Traceable In-House Calibration Certificate for your A3001FC

Fluke 3000-FC-GM Offers

Features

  • Communicate with your iOS (4s and later) and Android™ (4.3 and up) devices with the new Fluke Connect mobile app
  • Save money and time by taking multiple measurements simultaneously
  • Avoid awkward or uncomfortable measurement positions. Set up the measurement once, step back and read it as many times as you want, when you want
  • View up to 6 live readings at once on the Fluke Connect mobile app or a PC to get a complete understanding of the situation
  • Easily see backlit displays in dark or dimly lit work environments
  • Choose auto or manual ranging
  • Be in multiple places at once, reducing the risk of arc flash by separating yourself from hazardous measurement situations

A3000-FC Features

  • True-RMS AC clamp meter
  • Measure up to 400A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function
  • Compatible Models: Fluke 3000 FC DMM, Fluke Ti200/300/400 Infrared Camera, PC via optional pc3000 FC Adapter, Fluke Connect Mobile app

V3000-FC Features

  • True-RMS ac voltage module
  • Measure up to 1000 V
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • TL224 Test Leads
  • AC285 Alligator Clips
  • Magnetic hanging strap

Fluke 3000 FC General Maintenance Kit Specifications

AC Voltage
Range 600.0 mV
6.000 V
60.00 V
600.0 V
1000 V
Resolution 0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Accuracy 1.0 % + 3 from 45 Hz to 500 Hz
2.0 % + 3 from 500 Hz to 1 kHz
DC Voltage
Range 600.0 mV
6.000 V
60.00 V
600.0 V
1000 V
Resolution 0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Accuracy 0.09 % + 2
0.09 % + 2
0.15 % + 2
Continuity
Range 600 Ω
Resolution 1 Ω
Accuracy Meter beeps at <25 Ω, beeper detects opens or shorts of 250 µs or longer.
Resistance
Range 600.0 Ω
6.000 kΩ
60.00 kΩ
60.00 kΩ
600.0 kΩ
50.00 MΩ
Resolution 0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy 0.5 % + 2 @ 600.0 Ω
0.5% + 1 from 6.000 to 600.0 kΩ
1.5 % + 3 @ 50.00 MΩ
Diode Test
Range 2.000 V
Resolution 0.001 V
Accuracy 1 % + 2
Capacitance
Range 1000 nF
10.00 µF
100.0 µF
9999 µF
Resolution 1 nF
0.01 µF
0.1 µF
1 µF
Accuracy 1.2 % + 2 from 1000 nF to 100 µF
10 % Typical @ 9999 µF
AC and DC Current
Range 60.00 mA
400.0 mA
Resolution 0.01 mA
0.1 mA
Accuracy AC: 1.5 % + 3 from 45 Hz to 1 kHz
DC: 0.5 % + 3
Frequency
Range 99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
Resolution 0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
Accuracy 0.1 % + 1
Min/Max Recording
Accuracy DC Functions: ±12 counts for changes >350 ms in duration
AC Functions: ±40 counts for changes >900 ms in duration
General Specifications
Maximum Voltage Between Any Terminal and Earth Ground 1000 V DC or AC RMS
Fuse Protection from A Inputs 0.44 A (44/100 A, 440 mA)
1000 V FAST Fuse
Fluke Specified Part Only
Display (LCD) Update Rate: 4/sec
Volts, Amps, Ohms: 6000 Counts
Frequency: 10,000 Counts
Capacitance: 1,000 Counts
Battery Type 3 x AA Alkaline Batteries, NEDA 15A IEC LR6
Battery Life 250 Hours Minimum
RF Communications 2.4 GHZ ISM Band
RF Communication Range Open Air, Unobstructed: Up to 20m
Obstructed, Sheetrock Wall: Up to 6.5m
Obstructed, Concrete Wall, or Steel Electrical Enclosure: Up to 3.5m
Temperature Operating: -10 to 50°C
Storage: -40 to 60°C
Temperature Coefficient 0.1 x (Specified Accuracy)/°C (<18°C or >28°C)
Relative Humidity 0 to 90% (0 to 35°C)
0 to 75% (35 to 40°C)
0 to 45% (40 to 50°C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Electromagnetic Compatibility EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety Compliance ANSI/ISA 61010-1 / (82.02.01): 3rd Edition
CAN/CSA-C22.2 No 61010-1-12: 3rd Edition
UL 61010-1: 3rd Edition
IEC/EN 61010-1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) Rating IP54
Pollution Degree 2
Dimensions 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14")
Weight 340 g (12 oz)
Click here for complete specifications on the Fluke 3000 FC General Maintenance Kit

What's included with the Fluke 3000 FC General Maintenance Kit

  • Fluke 3000 FC General Maintenance Kit
This product features Fluke Connect Technology

See it. Save it. Share it. All the facts, right in the field.

Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.

Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.

Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.


Fluke Connect Features:

  • TrendIt™ Graphs: Use graphing to show changes in measurements, allowing you to graph and show problems instantly.
  • EquipmentLog™ History: Access equipment history building a database of equipment health and baselines with cloud backup.
  • ShareLive™ Video Calls: Save, collaborate and share measurements instantly with your team anytime, from anywhere.
  • AutoRecord™ Measurements: Instantly save measurements to your phone with Cloud backup.
  • Fluke Cloud™ Storage: Securely access equipment records anywhere, anytime.

Fluke Connect Benefits:

  • Maximize uptime
  • Minimize maintenance costs
  • Better assessments with accurate records
  • Higher efficiency with less walking around; no notebook and excel needed
  • Share troubleshooting knowledge live
  • Create and share helpful content in the field
  • Access to Fluke digital product manuals means no need to carry manuals in the field
  • Keep organized manually entered measurements

Multimeter measurements on adjustable speed drives

In the past, motor repair meant dealing with traditional three-phase motor failures that were largely the result of water, dust, grease, failed bearings, misaligned motor shafts, or just plain old age. But motor repair has changed in a big way with the introduction of electronically controlled motors, more commonly referred to as adjustable speed drives (ASDs). These drives present a unique set of measurement problems that can vex the most seasoned pro. Thanks to new technology, now for the first time you can take accurate electrical measurements with a DMM during the installation and maintenance of a drive and diagnose bad components and other conditions that may lead to premature failure.

Troubleshooting philosophy

Technicians use many different methods to troubleshoot an electrical circuit, and a good troubleshooter will always find the problem - eventually. The trick is tracking it down quickly and keeping downtime to a minimum. The most efficient troubleshooting procedure begins at the motor and then works systematically back to the electrical source, looking for the most obvious problems first. A lot of time and money can be wasted replacing perfectly good parts when the problem is simply a loose connection. As you go, take care to take accurate measurements. Nobody takes inaccurate measurements on purpose, but it's easy to do, especially when working in a high-energy, noisy environment like an ASD. Likewise, choosing the right test tools for troubleshooting the drive, the motor, and the connections are of utmost importance. This is especially true when taking voltage, frequency, and current measurements on the output side of the motor drive. But until now, there hasn't been a digital multimeter on the market able to accurately measure ASDs. Incorporates a selectable low pass filter* that allows for accurate drive output measurements that agree with the motor drive controller display indicator. Now, technicians won't have to guess whether the drive is operating correctly and delivering the correct voltage, current, or frequency for a given control setting.

Drive measurements

Input side measurements

Any good quality True RMS multimeter can verify proper input power to an ASD. The input voltage readings should be within 1% of one another when measured from phase to phase with no load. A significant unbalance may lead to erratic drive operation and should be corrected when discovered.

Output side measurements

On the flip side, a regular True RMS multimeter can't reliably read the output side of a pulse width modulated (PWM) motor drive, because the ASD applies pulse width modulated nonsinusoidal voltage to the motor terminals. A True RMS DMM reads the heating effect of the non-sinusoidal voltage applied to the motor, while the motor controller's output voltage reading only displays the RMS value of the fundamental component (typically from 30 Hz to 60 Hz). The causes of this discrepancy are bandwidth and shielding. Many of today's True RMS digital multimeters have bandwidths out to 20 kHz or more, causing them to respond not only to the fundamental component, which is what the motor responds to but to all of the high-frequency components generated by the PWM drive. And if the DMM isn't shielded for high-frequency noise, the drive controller's high noise levels make the measurement discrepancies even more extreme. With the bandwidth and shielding issues combined, many True RMS meters display readings as much as 20 to 30% higher than what the drive controller is indicating. The incorporated selectable low pass filter allows troubleshooters to take accurate voltage, current, and frequency measurements on the output side of the drive at either the drive itself or the motor terminals. With the filter selected, the readings for both voltage and frequency (motor speed) should agree with the associated drive control display indications, if available. The low pass filter also allows for accurate current measurements when used with Hall-effect type clamps. All of these measurements are especially helpful when taking measurements at the motor location when the drive's displays are not in view.

Taking safe measurements

Before taking any electrical measurements, be sure you understand how to take them safely. No test instrument is completely safe if used improperly, and many test instruments are not appropriate for testing adjustable speed drives. Also, make sure to use the appropriate personal protective equipment (PPE) for your specific working environment and measurements. If at all possible, never work alone.

Safety ratings for electrical test equipment

ANSI and the International Electrotechnical Commission (IEC) are the primary independent organizations that define safety standards for test equipment manufacturers. The IEC 61010 second edition standard for test equipment safety states two basic parameters: a voltage rating and a measurement category rating. The voltage rating is the maximum continuous working voltage the instrument is capable of measuring. The category ratings depict the measurement environment expected for a given category. Most three-phase ASD installations would be considered a CAT III measurement environment, with power supplied from either 480V or 600V distribution systems. When using a DMM for measurements on these high-energy systems, make sure it's rated at a minimum for CAT III 600V and preferably for CAT IV 600V/CAT III 1000V. The category rating and voltage limit are typically found on the front panel, at the input terminals. Dual-rated CAT IV 600V and CAT III 1000V. Refer to the ABC's of DMM Safety* from Fluke for additional information on category ratings and taking safe measurements.

How to take measurements

Now let's put the multimeter to the test. The measurements in the following procedure are designed to be made on a 480 volt 3 phase drive control at the control panel terminal strips. These procedures would also be valid for lower voltage 3 phase drives powered by either single or 3 phase supply voltages. For these tests, the motor is running at 50 Hz.

Input voltage

To measure the ac voltage supply to the input side of the drive at the drive:

  • Select the ac voltage function.
  • Connect the black probe to one of the three phase input terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase input terminals and record the reading.
  • Leaving the black probe on the reference phase now move the red probe to the third phase input and record this reading.
  • Make sure there's no more than a 1% difference between these two readings.

Input current

Measuring the input current generally requires a current clamp accessory. In most cases, either the input current exceeds the maximum current measurable by the current function, or it isn't practical to "break the circuit" to take an in-line series current measurement. Regardless of clamp type, insure that all readings are within 10% of each other for proper balance.

Transformer type clamp (i200, 80i-400, 80i-600A)

  • Connect the clamp to the common and 400 mA input jacks.
  • Select the mA/A AC function.
  • Place the clamp around each of the input supply phase cables in succession, recording each of the readings as they are taken. Since these clamps output one milliamp per amp, the milliamp readings shown on the display are the actual phase current readings in amps.

Hall Effect type (AC/DC) clamp (i410,i-1010)

  • Connect the clamp to the common and V/W input jacks.
  • Select the AC voltage function.
  • Press the yellow button to enable the low pass filter. This allows the meter to reject all of the high frequency noise generated by the drive controller. Once the low pass filter is enabled, the meter will be in the 600 mV manual range mode.
  • Place the clamp around each of the input supply phase cables in succession, recording each of the readings as they are taken. Since these clamps output one millivolt per amp, the millivolt readings shown on the display are the actual phase current readings in amps.

Figure 1. Output voltage reading without using the low pass filter.


Figure 2. Output voltage reading with low pass filter enabled.

Output voltage

To measure the AC output voltage at either the drive or the motor terminals:

  • Plug the black test lead into the common jack and the red test lead into the V/W jack.
  • Select the AC voltage function.
  • Connect the black probe to one of the three phase output voltage or motor terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase output voltage or motor terminals.
  • Press the yellow button to enable the low pass filter. Now record the reading.
  • Leaving the black probe on the reference phase, now move the red probe to the third phase output voltage or motor terminal and record this reading.
  • Make sure that there's no more than a 1% difference between these two readings (see Figure 2). The readings should also agree with the controller display, panel if available.
  • If the low pass filter isn't enabled, the output voltage readings may be 10 to 30% higher, as on a regular DMM (see Figure 1).

Figure 3. Output frequency (motor speed) without the low pass filter.


Figure 4. Output frequency (motor speed) using the low pass filter.

Motor speed (Output frequency using voltage as a reference)

To determine motor speed, simply take a frequency measurement while using the low pass filter. The measurement can be made between any two of the phase voltage or motor terminals.

  • Plug the black test lead into the common jack and the red test lead into the V/W jack.
  • Select the ac voltage function.
  • Connect the black probe to one of the three phase output voltage or motor terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase output voltage or motor terminals.
  • Press the yellow button to enable the low pass filter.
  • Press the Hz button. The displayed reading in hertz will be the motor speed (see Figure 3). This measurement couldn't be made successfully without the low pass filter (see Figure 4).

Output current

TAs with input current, measuring the output current generally requires a current clamp accessory. Once again, regardless of clamp type, insure that all readings are within 10% of each other for proper balance.

Transformer type clamp (i200, 80i-400, 80i-600A)

  • Connect the clamp to the common and 400 mA input jacks.
  • Select the mA/A ac function.
  • Place the clamp around each of the output phase cables in succession, recording each of the readings as they're taken. Since these clamps output 1 milliamp per amp, the milliamp readings shown on the display are the actual phase current readings in amps.

Figure 5. Output current reading without using the low pass filter.


Figure 6. Output current reading with low pass filter enabled.

Hall Effect type (AC/DC) clamp (i410,i-1010)

  • Connect the clamp to the common and V/W input jacks.
  • Select the ac voltage function.
  • Press the yellow button to enable the low pass filter. This allows the meter to reject all of the high frequency noise generated by the drive controller. Once the low pass filter is turned on, the meter will be in the 600 mV manual range mode.
  • Place the clamp around each of the output phase cables in succession, recording each of the readings as they are taken (see Figure 6). Since these clamps output 1 millivolt per amp, the millivolt readings shown on the 87-V display are the actual phase current readings in amps. This measurement would not be possible without the low pass filter (see Figure 5).

Motor speed (Output frequency using current as a reference)

For motors that pull at least 20 amps of running current, motor speed can be determined by taking a frequency measurement with current clamps. Until now, noise issues have prevented accurate readings using hall effect type clamps. Here's how the low pass filter makes it possible.

Motor speed using a Hall Effect type (AC/DC) clamp (i410,i-1010)

  • Connect the clamp to the common and V/W input jacks.
  • Select the ac voltage function.
  • Press the yellow button to enable the low pass filter. This allows the meter to reject all of the high frequency noise generated by the drive controller. Once the low pass filter has been turned on, the meter will be in the 600 mV manual range mode.
  • Place the clamp around one of the output phase cables. Verify that the multimeter is reading a current of at least 20 amps (20 mV in the display).
  • Press the Hz button. The readings now display the motor speed as a frequency measurement.

Motor speed using a transformer type clamp (i200, 80i-400, 80i-600A)

  • Connect the clamp to the common and 400 mA input jacks.
  • Select the mA/A AC function.
  • Place the clamp around one of the output phase cables. Verify that the multimeter is reading a current of at least 20 amps (20mA in the display).
  • Press the Hz button. The readings now display the motor speed as a frequency measurement.

DC Bus measurements

A healthy dc bus is a must for a properly operating motor drive. If the bus voltage is incorrect or unstable, the converter diodes or capacitors may be starting to fail. The DC bus voltage should be approximately 1.414 times the phase to phase input voltage. For a 480 volt input, the DC bus should be approximately 679 VDC. The DC bus is typically labeled as DC+, DC- or B+, Bon the drive terminal strip. To measure the DC bus voltage:

  • Select the dc voltage function.
  • Connect the black probe to either the DC- or B- terminal.
  • Connect the red probe to the DC+ or B+ terminal. The bus voltage should agree with the example mentioned above and be relatively stable. To check the amount of ac ripple on the bus, switch the 7V's function switch to the vac function. Some small drives don't allow external access to the DC bus measurement without disassembling the drive. If you can't access the DC bus, use the peak min max function on the multimeter to measure the dc bus voltage via the output voltage signal.
  • Plug the black test lead into the common jack and the red test lead into the V/½ jack.
  • Select the AC voltage function.
  • Connect the black probe to one of the three phase output voltage or motor terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase output voltage or motor terminals.
  • Press the min/max button.
  • Press the (Peak min/max) button.
  • The displayed reading in Peak min/max will be the DC bus voltage.

Click on a category to view a selection of compatible accessories with the Fluke 3000 FC General Maintenance Kit.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke A3000 FC Wireless AC Current Clamp Module A3000FC
The A3000 FC Wireless Current Clamp Meter is a fully functional True-RMS current clamp meter that wirelessly relays AC measurements to any Fluke Connect system.




Fluke A3001 FC Wireless iFlex AC Current Module A3001FC
The A3001 FC Wireless iFlex AC Current Module that wirelessly relays measurements to any Fluke Connect system.




Fluke A3002 FC Wireless AC/DC Current Module A3002FC
Wirelessly receives and pass measurements from the i410 or i1010 AC/DC clamps accessories and other Fluke Connect™ enabled master units with this wireless AC/C current module.




Fluke V3000 FC Wireless True-rms AC Voltage Module V3000FC
The V3000 FC Wireless Voltage Module measures true-rms AC voltage and relays measurements to any Fluke Connect master units




Fluke V3001 FC Wireless DC Voltage Module V3001FC
The V3001 FC Wireless Voltage Module measures DC voltage and relays measurements to any Fluke Connect master units




Fluke T3000 FC Wireless K-Type Temperature Module T3000-FC
Share test data through the Fluke Connect app when you pair this k-type temperature module with any other Fluke Connect remote modules. This allows you to access live readings without being exposed to the live panel. Additionally, you can identify temperature differences between the three phases.




Ask a question about Fluke 3000 FC General Maintenance Kit

Customer Reviews for the Fluke 3000 FC General Maintenance Kit

Fluke 3000-FC-GM Offers

Features

  • Communicate with your iOS (4s and later) and Android™ (4.3 and up) devices with the new Fluke Connect mobile app
  • Save money and time by taking multiple measurements simultaneously
  • Avoid awkward or uncomfortable measurement positions. Set up the measurement once, step back and read it as many times as you want, when you want
  • View up to 6 live readings at once on the Fluke Connect mobile app or a PC to get a complete understanding of the situation
  • Easily see backlit displays in dark or dimly lit work environments
  • Choose auto or manual ranging
  • Be in multiple places at once, reducing the risk of arc flash by separating yourself from hazardous measurement situations

A3000-FC Features

  • True-RMS AC clamp meter
  • Measure up to 400A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function
  • Compatible Models: Fluke 3000 FC DMM, Fluke Ti200/300/400 Infrared Camera, PC via optional pc3000 FC Adapter, Fluke Connect Mobile app

V3000-FC Features

  • True-RMS ac voltage module
  • Measure up to 1000 V
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • TL224 Test Leads
  • AC285 Alligator Clips
  • Magnetic hanging strap

Fluke 3000 FC General Maintenance Kit Specifications

AC Voltage
Range 600.0 mV
6.000 V
60.00 V
600.0 V
1000 V
Resolution 0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Accuracy 1.0 % + 3 from 45 Hz to 500 Hz
2.0 % + 3 from 500 Hz to 1 kHz
DC Voltage
Range 600.0 mV
6.000 V
60.00 V
600.0 V
1000 V
Resolution 0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Accuracy 0.09 % + 2
0.09 % + 2
0.15 % + 2
Continuity
Range 600 Ω
Resolution 1 Ω
Accuracy Meter beeps at <25 Ω, beeper detects opens or shorts of 250 µs or longer.
Resistance
Range 600.0 Ω
6.000 kΩ
60.00 kΩ
60.00 kΩ
600.0 kΩ
50.00 MΩ
Resolution 0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy 0.5 % + 2 @ 600.0 Ω
0.5% + 1 from 6.000 to 600.0 kΩ
1.5 % + 3 @ 50.00 MΩ
Diode Test
Range 2.000 V
Resolution 0.001 V
Accuracy 1 % + 2
Capacitance
Range 1000 nF
10.00 µF
100.0 µF
9999 µF
Resolution 1 nF
0.01 µF
0.1 µF
1 µF
Accuracy 1.2 % + 2 from 1000 nF to 100 µF
10 % Typical @ 9999 µF
AC and DC Current
Range 60.00 mA
400.0 mA
Resolution 0.01 mA
0.1 mA
Accuracy AC: 1.5 % + 3 from 45 Hz to 1 kHz
DC: 0.5 % + 3
Frequency
Range 99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
Resolution 0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
Accuracy 0.1 % + 1
Min/Max Recording
Accuracy DC Functions: ±12 counts for changes >350 ms in duration
AC Functions: ±40 counts for changes >900 ms in duration
General Specifications
Maximum Voltage Between Any Terminal and Earth Ground 1000 V DC or AC RMS
Fuse Protection from A Inputs 0.44 A (44/100 A, 440 mA)
1000 V FAST Fuse
Fluke Specified Part Only
Display (LCD) Update Rate: 4/sec
Volts, Amps, Ohms: 6000 Counts
Frequency: 10,000 Counts
Capacitance: 1,000 Counts
Battery Type 3 x AA Alkaline Batteries, NEDA 15A IEC LR6
Battery Life 250 Hours Minimum
RF Communications 2.4 GHZ ISM Band
RF Communication Range Open Air, Unobstructed: Up to 20m
Obstructed, Sheetrock Wall: Up to 6.5m
Obstructed, Concrete Wall, or Steel Electrical Enclosure: Up to 3.5m
Temperature Operating: -10 to 50°C
Storage: -40 to 60°C
Temperature Coefficient 0.1 x (Specified Accuracy)/°C (<18°C or >28°C)
Relative Humidity 0 to 90% (0 to 35°C)
0 to 75% (35 to 40°C)
0 to 45% (40 to 50°C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Electromagnetic Compatibility EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety Compliance ANSI/ISA 61010-1 / (82.02.01): 3rd Edition
CAN/CSA-C22.2 No 61010-1-12: 3rd Edition
UL 61010-1: 3rd Edition
IEC/EN 61010-1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) Rating IP54
Pollution Degree 2
Dimensions 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14")
Weight 340 g (12 oz)
Click here for complete specifications on the Fluke 3000 FC General Maintenance Kit

What's included with the Fluke 3000 FC General Maintenance Kit

  • Fluke 3000 FC General Maintenance Kit
This product features Fluke Connect Technology

See it. Save it. Share it. All the facts, right in the field.

Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.

Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.

Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.


Fluke Connect Features:

  • TrendIt™ Graphs: Use graphing to show changes in measurements, allowing you to graph and show problems instantly.
  • EquipmentLog™ History: Access equipment history building a database of equipment health and baselines with cloud backup.
  • ShareLive™ Video Calls: Save, collaborate and share measurements instantly with your team anytime, from anywhere.
  • AutoRecord™ Measurements: Instantly save measurements to your phone with Cloud backup.
  • Fluke Cloud™ Storage: Securely access equipment records anywhere, anytime.

Fluke Connect Benefits:

  • Maximize uptime
  • Minimize maintenance costs
  • Better assessments with accurate records
  • Higher efficiency with less walking around; no notebook and excel needed
  • Share troubleshooting knowledge live
  • Create and share helpful content in the field
  • Access to Fluke digital product manuals means no need to carry manuals in the field
  • Keep organized manually entered measurements

Multimeter measurements on adjustable speed drives

In the past, motor repair meant dealing with traditional three-phase motor failures that were largely the result of water, dust, grease, failed bearings, misaligned motor shafts, or just plain old age. But motor repair has changed in a big way with the introduction of electronically controlled motors, more commonly referred to as adjustable speed drives (ASDs). These drives present a unique set of measurement problems that can vex the most seasoned pro. Thanks to new technology, now for the first time you can take accurate electrical measurements with a DMM during the installation and maintenance of a drive and diagnose bad components and other conditions that may lead to premature failure.

Troubleshooting philosophy

Technicians use many different methods to troubleshoot an electrical circuit, and a good troubleshooter will always find the problem - eventually. The trick is tracking it down quickly and keeping downtime to a minimum. The most efficient troubleshooting procedure begins at the motor and then works systematically back to the electrical source, looking for the most obvious problems first. A lot of time and money can be wasted replacing perfectly good parts when the problem is simply a loose connection. As you go, take care to take accurate measurements. Nobody takes inaccurate measurements on purpose, but it's easy to do, especially when working in a high-energy, noisy environment like an ASD. Likewise, choosing the right test tools for troubleshooting the drive, the motor, and the connections are of utmost importance. This is especially true when taking voltage, frequency, and current measurements on the output side of the motor drive. But until now, there hasn't been a digital multimeter on the market able to accurately measure ASDs. Incorporates a selectable low pass filter* that allows for accurate drive output measurements that agree with the motor drive controller display indicator. Now, technicians won't have to guess whether the drive is operating correctly and delivering the correct voltage, current, or frequency for a given control setting.

Drive measurements

Input side measurements

Any good quality True RMS multimeter can verify proper input power to an ASD. The input voltage readings should be within 1% of one another when measured from phase to phase with no load. A significant unbalance may lead to erratic drive operation and should be corrected when discovered.

Output side measurements

On the flip side, a regular True RMS multimeter can't reliably read the output side of a pulse width modulated (PWM) motor drive, because the ASD applies pulse width modulated nonsinusoidal voltage to the motor terminals. A True RMS DMM reads the heating effect of the non-sinusoidal voltage applied to the motor, while the motor controller's output voltage reading only displays the RMS value of the fundamental component (typically from 30 Hz to 60 Hz). The causes of this discrepancy are bandwidth and shielding. Many of today's True RMS digital multimeters have bandwidths out to 20 kHz or more, causing them to respond not only to the fundamental component, which is what the motor responds to but to all of the high-frequency components generated by the PWM drive. And if the DMM isn't shielded for high-frequency noise, the drive controller's high noise levels make the measurement discrepancies even more extreme. With the bandwidth and shielding issues combined, many True RMS meters display readings as much as 20 to 30% higher than what the drive controller is indicating. The incorporated selectable low pass filter allows troubleshooters to take accurate voltage, current, and frequency measurements on the output side of the drive at either the drive itself or the motor terminals. With the filter selected, the readings for both voltage and frequency (motor speed) should agree with the associated drive control display indications, if available. The low pass filter also allows for accurate current measurements when used with Hall-effect type clamps. All of these measurements are especially helpful when taking measurements at the motor location when the drive's displays are not in view.

Taking safe measurements

Before taking any electrical measurements, be sure you understand how to take them safely. No test instrument is completely safe if used improperly, and many test instruments are not appropriate for testing adjustable speed drives. Also, make sure to use the appropriate personal protective equipment (PPE) for your specific working environment and measurements. If at all possible, never work alone.

Safety ratings for electrical test equipment

ANSI and the International Electrotechnical Commission (IEC) are the primary independent organizations that define safety standards for test equipment manufacturers. The IEC 61010 second edition standard for test equipment safety states two basic parameters: a voltage rating and a measurement category rating. The voltage rating is the maximum continuous working voltage the instrument is capable of measuring. The category ratings depict the measurement environment expected for a given category. Most three-phase ASD installations would be considered a CAT III measurement environment, with power supplied from either 480V or 600V distribution systems. When using a DMM for measurements on these high-energy systems, make sure it's rated at a minimum for CAT III 600V and preferably for CAT IV 600V/CAT III 1000V. The category rating and voltage limit are typically found on the front panel, at the input terminals. Dual-rated CAT IV 600V and CAT III 1000V. Refer to the ABC's of DMM Safety* from Fluke for additional information on category ratings and taking safe measurements.

How to take measurements

Now let's put the multimeter to the test. The measurements in the following procedure are designed to be made on a 480 volt 3 phase drive control at the control panel terminal strips. These procedures would also be valid for lower voltage 3 phase drives powered by either single or 3 phase supply voltages. For these tests, the motor is running at 50 Hz.

Input voltage

To measure the ac voltage supply to the input side of the drive at the drive:

  • Select the ac voltage function.
  • Connect the black probe to one of the three phase input terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase input terminals and record the reading.
  • Leaving the black probe on the reference phase now move the red probe to the third phase input and record this reading.
  • Make sure there's no more than a 1% difference between these two readings.

Input current

Measuring the input current generally requires a current clamp accessory. In most cases, either the input current exceeds the maximum current measurable by the current function, or it isn't practical to "break the circuit" to take an in-line series current measurement. Regardless of clamp type, insure that all readings are within 10% of each other for proper balance.

Transformer type clamp (i200, 80i-400, 80i-600A)

  • Connect the clamp to the common and 400 mA input jacks.
  • Select the mA/A AC function.
  • Place the clamp around each of the input supply phase cables in succession, recording each of the readings as they are taken. Since these clamps output one milliamp per amp, the milliamp readings shown on the display are the actual phase current readings in amps.

Hall Effect type (AC/DC) clamp (i410,i-1010)

  • Connect the clamp to the common and V/W input jacks.
  • Select the AC voltage function.
  • Press the yellow button to enable the low pass filter. This allows the meter to reject all of the high frequency noise generated by the drive controller. Once the low pass filter is enabled, the meter will be in the 600 mV manual range mode.
  • Place the clamp around each of the input supply phase cables in succession, recording each of the readings as they are taken. Since these clamps output one millivolt per amp, the millivolt readings shown on the display are the actual phase current readings in amps.

Figure 1. Output voltage reading without using the low pass filter.


Figure 2. Output voltage reading with low pass filter enabled.

Output voltage

To measure the AC output voltage at either the drive or the motor terminals:

  • Plug the black test lead into the common jack and the red test lead into the V/W jack.
  • Select the AC voltage function.
  • Connect the black probe to one of the three phase output voltage or motor terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase output voltage or motor terminals.
  • Press the yellow button to enable the low pass filter. Now record the reading.
  • Leaving the black probe on the reference phase, now move the red probe to the third phase output voltage or motor terminal and record this reading.
  • Make sure that there's no more than a 1% difference between these two readings (see Figure 2). The readings should also agree with the controller display, panel if available.
  • If the low pass filter isn't enabled, the output voltage readings may be 10 to 30% higher, as on a regular DMM (see Figure 1).

Figure 3. Output frequency (motor speed) without the low pass filter.


Figure 4. Output frequency (motor speed) using the low pass filter.

Motor speed (Output frequency using voltage as a reference)

To determine motor speed, simply take a frequency measurement while using the low pass filter. The measurement can be made between any two of the phase voltage or motor terminals.

  • Plug the black test lead into the common jack and the red test lead into the V/W jack.
  • Select the ac voltage function.
  • Connect the black probe to one of the three phase output voltage or motor terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase output voltage or motor terminals.
  • Press the yellow button to enable the low pass filter.
  • Press the Hz button. The displayed reading in hertz will be the motor speed (see Figure 3). This measurement couldn't be made successfully without the low pass filter (see Figure 4).

Output current

TAs with input current, measuring the output current generally requires a current clamp accessory. Once again, regardless of clamp type, insure that all readings are within 10% of each other for proper balance.

Transformer type clamp (i200, 80i-400, 80i-600A)

  • Connect the clamp to the common and 400 mA input jacks.
  • Select the mA/A ac function.
  • Place the clamp around each of the output phase cables in succession, recording each of the readings as they're taken. Since these clamps output 1 milliamp per amp, the milliamp readings shown on the display are the actual phase current readings in amps.

Figure 5. Output current reading without using the low pass filter.


Figure 6. Output current reading with low pass filter enabled.

Hall Effect type (AC/DC) clamp (i410,i-1010)

  • Connect the clamp to the common and V/W input jacks.
  • Select the ac voltage function.
  • Press the yellow button to enable the low pass filter. This allows the meter to reject all of the high frequency noise generated by the drive controller. Once the low pass filter is turned on, the meter will be in the 600 mV manual range mode.
  • Place the clamp around each of the output phase cables in succession, recording each of the readings as they are taken (see Figure 6). Since these clamps output 1 millivolt per amp, the millivolt readings shown on the 87-V display are the actual phase current readings in amps. This measurement would not be possible without the low pass filter (see Figure 5).

Motor speed (Output frequency using current as a reference)

For motors that pull at least 20 amps of running current, motor speed can be determined by taking a frequency measurement with current clamps. Until now, noise issues have prevented accurate readings using hall effect type clamps. Here's how the low pass filter makes it possible.

Motor speed using a Hall Effect type (AC/DC) clamp (i410,i-1010)

  • Connect the clamp to the common and V/W input jacks.
  • Select the ac voltage function.
  • Press the yellow button to enable the low pass filter. This allows the meter to reject all of the high frequency noise generated by the drive controller. Once the low pass filter has been turned on, the meter will be in the 600 mV manual range mode.
  • Place the clamp around one of the output phase cables. Verify that the multimeter is reading a current of at least 20 amps (20 mV in the display).
  • Press the Hz button. The readings now display the motor speed as a frequency measurement.

Motor speed using a transformer type clamp (i200, 80i-400, 80i-600A)

  • Connect the clamp to the common and 400 mA input jacks.
  • Select the mA/A AC function.
  • Place the clamp around one of the output phase cables. Verify that the multimeter is reading a current of at least 20 amps (20mA in the display).
  • Press the Hz button. The readings now display the motor speed as a frequency measurement.

DC Bus measurements

A healthy dc bus is a must for a properly operating motor drive. If the bus voltage is incorrect or unstable, the converter diodes or capacitors may be starting to fail. The DC bus voltage should be approximately 1.414 times the phase to phase input voltage. For a 480 volt input, the DC bus should be approximately 679 VDC. The DC bus is typically labeled as DC+, DC- or B+, Bon the drive terminal strip. To measure the DC bus voltage:

  • Select the dc voltage function.
  • Connect the black probe to either the DC- or B- terminal.
  • Connect the red probe to the DC+ or B+ terminal. The bus voltage should agree with the example mentioned above and be relatively stable. To check the amount of ac ripple on the bus, switch the 7V's function switch to the vac function. Some small drives don't allow external access to the DC bus measurement without disassembling the drive. If you can't access the DC bus, use the peak min max function on the multimeter to measure the dc bus voltage via the output voltage signal.
  • Plug the black test lead into the common jack and the red test lead into the V/½ jack.
  • Select the AC voltage function.
  • Connect the black probe to one of the three phase output voltage or motor terminals. This will be the reference phase.
  • Connect the red probe to one of the other two phase output voltage or motor terminals.
  • Press the min/max button.
  • Press the (Peak min/max) button.
  • The displayed reading in Peak min/max will be the DC bus voltage.

Click on a category to view a selection of compatible accessories with the Fluke 3000 FC General Maintenance Kit.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Fluke A3000 FC Wireless AC Current Clamp Module A3000FC
The A3000 FC Wireless Current Clamp Meter is a fully functional True-RMS current clamp meter that wirelessly relays AC measurements to any Fluke Connect system.




Fluke A3001 FC Wireless iFlex AC Current Module A3001FC
The A3001 FC Wireless iFlex AC Current Module that wirelessly relays measurements to any Fluke Connect system.




Fluke A3002 FC Wireless AC/DC Current Module A3002FC
Wirelessly receives and pass measurements from the i410 or i1010 AC/DC clamps accessories and other Fluke Connect™ enabled master units with this wireless AC/C current module.




Fluke V3000 FC Wireless True-rms AC Voltage Module V3000FC
The V3000 FC Wireless Voltage Module measures true-rms AC voltage and relays measurements to any Fluke Connect master units




Fluke V3001 FC Wireless DC Voltage Module V3001FC
The V3001 FC Wireless Voltage Module measures DC voltage and relays measurements to any Fluke Connect master units




Fluke T3000 FC Wireless K-Type Temperature Module T3000-FC
Share test data through the Fluke Connect app when you pair this k-type temperature module with any other Fluke Connect remote modules. This allows you to access live readings without being exposed to the live panel. Additionally, you can identify temperature differences between the three phases.




Ask a question about Fluke 3000 FC General Maintenance Kit

Customer Reviews for the Fluke 3000 FC General Maintenance Kit

More Fluke Products

Between March 11 and June 30, 2024 spend $500 or more and get a free Fluke tool or bundle with your purchase.

Fluke Connect is the best way to stay in contact with your team without leaving the field.


Calibration Lab