Confidently take reliable readings with this clamp meter. This unit easily clamps around large conductors that are commonly found in high-current applications due to its extra-large jaw clamp. Additionally, this also measures voltage and resistance.
Confidently take reliable readings with this clamp meter. This unit easily clamps around large conductors that are commonly found in high-current applications due to its extra-large jaw clamp. Additionally, this also measures voltage and resistance.
Versatile and rugged tools for applications with high currents
Take reliable readings with this True RMS clamp meter confidently. Ideal for high-current measurements up to 2000 A, this clamp meter features an extra-wide jaw easily clamps around large conductors typically found in high-current applications. With a rugged design and CAT IV 600 V, CAT III 1000 V ratings provide an extra element of protection when taking high-powered measurements.
Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. Also, it measures voltage and resistance, making this tool ideal for utilities, electrical contractors, and industrial service technicians.
Features
Applications
Current Measurement DC and AC 10 to 100 Hz | |
Range | 40 A/400 A/2000 A/1400 AC RMS |
Resolution | 10 mA/100 mA/1 A |
Accuracy | A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits |
Trigger Level for Inrush | 0.50 A/5.0 A/5 A |
Trigger Level for Hz Filter OFF | 2.50 A/2.5 A/8 A |
Trigger Level for Hz Filter ON | 0.50 A/2.5 A/8 A |
Crest Factor (50/60 Hz) | |
Range | 40 A/400 A/2000 A/1400 AC RMS |
Crest Factor | 2 at 33 A, 2.4 at 27 A 2 at 330 A, 2.4 at 270 A 2 at 1000 A, 2.4 at 833 A |
Current Measurement AC 100.1 Hz to 1 kHz | |
Range | 40 A/400 A/2000 A; 1400 AC RMS |
Resolution | 10 mA/100 mA/1 A |
Accuracy | 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits |
Trigger Level for Inrush | 0.50 A/5.0 A/5 A |
Trigger Level for Hz Filter OFF | 2.50 A/2.5 A/8 A |
Trigger Level for Hz Filter ON | 0.50 A/2.5 A/8 A |
Voltage Measurement DC and AC 10 to 100 Hz (600 and 1000 V ranges have 10% over range to 660 and 1100 V respectively) | |
Range | 4 V/40 V/400 V/600 V AC RMS/1000 VDC |
Resolution | 1 mV/10 mV/100 mV/1 V |
Accuracy | 1% rdg + 10 digits 1% rdg + 5 digits |
Trigger Level for Hz Filter OFF | 0.25 V/6 V |
Trigger Level for Hz Filter ON | 0.25 V/6 V |
Voltage measurement AC 100.1 Hz to 1 kHz (600 and 1000 V ranges have 10% over range to 660 and 1100 V respectively) | |
Range | 4 V/40 V/400 V/600 V AC RMS/1000 VDC |
Resolution | 1 mV/10 mV/100 mV/1 V |
Accuracy | 3% rdg + 10 digits 3% rdg + 5 digits |
Trigger Level for Hz Filter OFF | 0.050 V/0.25 V/6 V |
Trigger Level for Hz Filter ON | 0.050 V/0.25 V /6 V |
Ohms Measurement | |
Range | 4 kΩ/40 kΩ/400 kΩ |
Resolution | 0.1 Ω/ 1 Ω/ 10 Ω/ 100 Ω |
Accuracy | 1.5% + 5 digits |
Continuity Beeper | |
On and Off | On at ≤ 30 Ω Off at > 100 Ω |
Frequency Measurement | |
Measurement Range | 5.0 Hz to 1 kHz |
Resolution | 0.1 Hz (15 Hz to 399.9 Hz) 1 Hz (400 Hz to 1 kHz) |
Accuracy | 5.0 to 100 Hz: 0.2% + 2 counts 100.1 Hz to 1 kHz: 0.5% + 5 counts |
Environmental Specifications | |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Operating Humidity | 0 to 95% (non-condensing) |
Operating Altitude | 6561.68' (2000 m) |
Storage Altitude | 32,808.4' (10,000 m) |
IP Rating | 42 (indoor use only) |
Drop Test Requirements | 3.28' (1 m) |
EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 |
Temperature Coefficients | Current: 0.1% of reading per °C outside 22 to 24°C Voltage: 0.1% of reading per °C outside 22 to 24°C |
General Specifications | |
Battery | Type: 6 x 1.5 V AA NEDA 15 A or IEC LR6 Life: 100 hours |
Test Leads | Rated to 1000 V |
Jaw Size | 2.28" (58 mm) |
Dimensions | 12 x 3.75 x 2" (300 x 98 x 52 mm) |
Weight | 1.8 lbs (0.814 kg) |
Safety Rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III |
Click on a category to view a selection of compatible accessories with the Fluke 355 True RMS Clamp Meter, 2000 A.
Current Measurement DC and AC 10 to 100 Hz | |
Range | 40 A/400 A/2000 A/1400 AC RMS |
Resolution | 10 mA/100 mA/1 A |
Accuracy | A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits |
Trigger Level for Inrush | 0.50 A/5.0 A/5 A |
Trigger Level for Hz Filter OFF | 2.50 A/2.5 A/8 A |
Trigger Level for Hz Filter ON | 0.50 A/2.5 A/8 A |
Crest Factor (50/60 Hz) | |
Range | 40 A/400 A/2000 A/1400 AC RMS |
Crest Factor | 2 at 33 A, 2.4 at 27 A 2 at 330 A, 2.4 at 270 A 2 at 1000 A, 2.4 at 833 A |
Current Measurement AC 100.1 Hz to 1 kHz | |
Range | 40 A/400 A/2000 A; 1400 AC RMS |
Resolution | 10 mA/100 mA/1 A |
Accuracy | 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits |
Trigger Level for Inrush | 0.50 A/5.0 A/5 A |
Trigger Level for Hz Filter OFF | 2.50 A/2.5 A/8 A |
Trigger Level for Hz Filter ON | 0.50 A/2.5 A/8 A |
Voltage Measurement DC and AC 10 to 100 Hz (600 and 1000 V ranges have 10% over range to 660 and 1100 V respectively) | |
Range | 4 V/40 V/400 V/600 V AC RMS/1000 VDC |
Resolution | 1 mV/10 mV/100 mV/1 V |
Accuracy | 1% rdg + 10 digits 1% rdg + 5 digits |
Trigger Level for Hz Filter OFF | 0.25 V/6 V |
Trigger Level for Hz Filter ON | 0.25 V/6 V |
Voltage measurement AC 100.1 Hz to 1 kHz (600 and 1000 V ranges have 10% over range to 660 and 1100 V respectively) | |
Range | 4 V/40 V/400 V/600 V AC RMS/1000 VDC |
Resolution | 1 mV/10 mV/100 mV/1 V |
Accuracy | 3% rdg + 10 digits 3% rdg + 5 digits |
Trigger Level for Hz Filter OFF | 0.050 V/0.25 V/6 V |
Trigger Level for Hz Filter ON | 0.050 V/0.25 V /6 V |
Ohms Measurement | |
Range | 4 kΩ/40 kΩ/400 kΩ |
Resolution | 0.1 Ω/ 1 Ω/ 10 Ω/ 100 Ω |
Accuracy | 1.5% + 5 digits |
Continuity Beeper | |
On and Off | On at ≤ 30 Ω Off at > 100 Ω |
Frequency Measurement | |
Measurement Range | 5.0 Hz to 1 kHz |
Resolution | 0.1 Hz (15 Hz to 399.9 Hz) 1 Hz (400 Hz to 1 kHz) |
Accuracy | 5.0 to 100 Hz: 0.2% + 2 counts 100.1 Hz to 1 kHz: 0.5% + 5 counts |
Environmental Specifications | |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Operating Humidity | 0 to 95% (non-condensing) |
Operating Altitude | 6561.68' (2000 m) |
Storage Altitude | 32,808.4' (10,000 m) |
IP Rating | 42 (indoor use only) |
Drop Test Requirements | 3.28' (1 m) |
EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 |
Temperature Coefficients | Current: 0.1% of reading per °C outside 22 to 24°C Voltage: 0.1% of reading per °C outside 22 to 24°C |
General Specifications | |
Battery | Type: 6 x 1.5 V AA NEDA 15 A or IEC LR6 Life: 100 hours |
Test Leads | Rated to 1000 V |
Jaw Size | 2.28" (58 mm) |
Dimensions | 12 x 3.75 x 2" (300 x 98 x 52 mm) |
Weight | 1.8 lbs (0.814 kg) |
Safety Rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III |