Equipped with Inconel sheaths and mini spade lug connections, this secondary PRT has various calibration options and a -200 to 670°C range to suit your needs.
Equipped with Inconel sheaths and mini spade lug connections, this secondary PRT has various calibration options and a -200 to 670°C range to suit your needs.
Features
Temperature Range | -328 to 1,238°F (-200 to 670°C) |
Nominal Resistance at 0.01°C | 100Ω ±0.5Ω |
Temperature Coefficient | 0.0039250Ω/Ω/°C |
Short-Term Repeatability | ±0.01 at 0.010°C; ±0.02°C at max temp |
Drift | ±0.01 at 0.010°C; ±0.02°C at max temp |
Hysteresis | ±0.01°C maximum |
Sensor Length | 1.2in ±0.2in (30mm ±5mm) |
Sensor Location | 0.1in ±0.1in (3mm ±1mm from tip) |
Minimum Insulation Resistance | 500MΩ at 23°C, 10MΩ at 670°C |
Transition Junction Dimensions | 2.8 x 0.49in (71 x 12.5mm) |
Minimum Immersion Length (<5 mK Error) | 3.9in (100mm) |
Maximum Immersion Length | 12in (305mm) |
Response Time | 12 seconds typical |
Self Heating (In 0°C Bath) | 50mW/°C |
Lead-Wire Cable Type | Teflon, 24AWG |
Lead-Wire Length | 6ft (1.8m) |
Lead-Wire Temperature Range | -58 to 482°F (-50 to 250°C) |
Calibration | Calibration not included; NVLAP-accredited calibration optional, lab code 200348-0; please see calibration uncertainty table and its explanation of changeable uncertainties |
Click on a category to view a selection of compatible accessories with the Fluke 5609-12-L Secondary PRT with Mini Spade Lugs, -200 to 670°C, Calibration Options.
Temperature Range | -328 to 1,238°F (-200 to 670°C) |
Nominal Resistance at 0.01°C | 100Ω ±0.5Ω |
Temperature Coefficient | 0.0039250Ω/Ω/°C |
Short-Term Repeatability | ±0.01 at 0.010°C; ±0.02°C at max temp |
Drift | ±0.01 at 0.010°C; ±0.02°C at max temp |
Hysteresis | ±0.01°C maximum |
Sensor Length | 1.2in ±0.2in (30mm ±5mm) |
Sensor Location | 0.1in ±0.1in (3mm ±1mm from tip) |
Minimum Insulation Resistance | 500MΩ at 23°C, 10MΩ at 670°C |
Transition Junction Dimensions | 2.8 x 0.49in (71 x 12.5mm) |
Minimum Immersion Length (<5 mK Error) | 3.9in (100mm) |
Maximum Immersion Length | 12in (305mm) |
Response Time | 12 seconds typical |
Self Heating (In 0°C Bath) | 50mW/°C |
Lead-Wire Cable Type | Teflon, 24AWG |
Lead-Wire Length | 6ft (1.8m) |
Lead-Wire Temperature Range | -58 to 482°F (-50 to 250°C) |
Calibration | Calibration not included; NVLAP-accredited calibration optional, lab code 200348-0; please see calibration uncertainty table and its explanation of changeable uncertainties |