Fluke 80i-2010s AC/DC Current Clamp, 2000 A

Model: 80i-2010s | UPC: 095969918770

Fluke 80i-2010s AC/DC Current Clamp, 2000 A

Model: 80i-2010s | UPC: 095969918770

An open-jaw, clamp-on current probe with a current range of 2000 A, and an accuracy of 0.8%, that is also safety rated for CAT III 1000 V, CAT IV 600 V environments.

An open-jaw, clamp-on current probe with a current range of 2000 A, and an accuracy of 0.8%, that is also safety rated for CAT III 1000 V, CAT IV 600 V environments.

Your Price $1209.99 USD
Availability 1 to 2 Weeks
Quantity

Traceable In-House Calibration Certificate for your to your

Traceable In-House Calibration Certificate for your to your

Fluke 80i-2010s Specifications

Electrical
Current Range 2000 A AC rms, ± 2000 A DC
Output Sensitivity 1 mV/A
Accuracy ±0.8% of reading ±0.2% of range
Bandwidth for Accuracy Specification DC to 400 Hz
Load Impedance >1 MΩ and <10 pF
Frequency Response (Small Signal) DC to 20 kHz (-3 dB)
Temperature Coefficient 0.1 x specified accuracy for each degree C above 28°C or below 18°C
Working Voltage 1000 V AC RMS or DC
General Specifications
Operating Temperature 14 to 122°F (-10 to 50°C)
Storage Temperature -22 to 140°F (-30 to 60°C), with battery removed
Operating Humidity ≤90% RH (at 50 to 86°F [10 to 30°C])
≤75% RH (at 86 to 104°F [30 to 40°C])
≤45% RH (at 104 to 122°F [40 to 50°C])
Altitude Operating: 6561.68' (2000 m)
Storage: 39,370.1' (12,000 m)
Demagnetize Clamp Open and close the clamp jaws several times with soft click, use of the clamp on uninsulated conductors is limited to 1000 Vac rms or DC and frequencies 1 kHz or less
Power Supply 2 x AA alkaline batteries, IEC LR6
Battery Life 150 hours (typically)
Low Battery Indicator Yes
Safety IEC 61010-1, Pollution Degree 2, IEC 61010-2-032: CAT III 1000 V /CAT IV 600 V
Ingress Protection IEC 60529, IP40
Output to Zero Auto adjustment with Zero button
Output Cable 60" (1.5 m) shielded coaxial cable with BNC plug
Maximum Conductor Size 2.05" (52 mm)
Maximum Jaw Opening 3.2" (81.5 mm)
Dimensions 4.33 x 10.63 x 1.81" (110 x 270 x 46 mm)
Weight 1.6 lbs (0.71 kg), including battery
Click here for complete specifications on the Fluke 80i-2010s

What's included with the Fluke 80i-2010s

  • Fluke 80i-2010s AC/DC Current Clamp, 2000 A

Click on a category to view a selection of compatible accessories with the Fluke 80i-2010s AC/DC Current Clamp, 2000 A.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 80i-2010s AC/DC Current Clamp, 2000 A

Customer Reviews for the Fluke 80i-2010s

Fluke 80i-2010s Specifications

Electrical
Current Range 2000 A AC rms, ± 2000 A DC
Output Sensitivity 1 mV/A
Accuracy ±0.8% of reading ±0.2% of range
Bandwidth for Accuracy Specification DC to 400 Hz
Load Impedance >1 MΩ and <10 pF
Frequency Response (Small Signal) DC to 20 kHz (-3 dB)
Temperature Coefficient 0.1 x specified accuracy for each degree C above 28°C or below 18°C
Working Voltage 1000 V AC RMS or DC
General Specifications
Operating Temperature 14 to 122°F (-10 to 50°C)
Storage Temperature -22 to 140°F (-30 to 60°C), with battery removed
Operating Humidity ≤90% RH (at 50 to 86°F [10 to 30°C])
≤75% RH (at 86 to 104°F [30 to 40°C])
≤45% RH (at 104 to 122°F [40 to 50°C])
Altitude Operating: 6561.68' (2000 m)
Storage: 39,370.1' (12,000 m)
Demagnetize Clamp Open and close the clamp jaws several times with soft click, use of the clamp on uninsulated conductors is limited to 1000 Vac rms or DC and frequencies 1 kHz or less
Power Supply 2 x AA alkaline batteries, IEC LR6
Battery Life 150 hours (typically)
Low Battery Indicator Yes
Safety IEC 61010-1, Pollution Degree 2, IEC 61010-2-032: CAT III 1000 V /CAT IV 600 V
Ingress Protection IEC 60529, IP40
Output to Zero Auto adjustment with Zero button
Output Cable 60" (1.5 m) shielded coaxial cable with BNC plug
Maximum Conductor Size 2.05" (52 mm)
Maximum Jaw Opening 3.2" (81.5 mm)
Dimensions 4.33 x 10.63 x 1.81" (110 x 270 x 46 mm)
Weight 1.6 lbs (0.71 kg), including battery
Click here for complete specifications on the Fluke 80i-2010s

What's included with the Fluke 80i-2010s

  • Fluke 80i-2010s AC/DC Current Clamp, 2000 A

Click on a category to view a selection of compatible accessories with the Fluke 80i-2010s AC/DC Current Clamp, 2000 A.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke 80i-2010s AC/DC Current Clamp, 2000 A

Customer Reviews for the Fluke 80i-2010s

More Fluke Products

Between March 11 and June 30, 2024 spend $500 or more and get a free Fluke tool or bundle with your purchase.
Calibration Lab