The kit provides accurate measurements for electrical properties. It ensures that processes are operating without malfunction.
The kit provides accurate measurements for electrical properties. It ensures that processes are operating without malfunction.
Discontinued!
This product has been discontinued and is no longer available.
There is no direct replacement, however we recommend the:
Not what you're looking for? Let’s do a search and help you find what you need.
Optimize performance, results and calibration processes with this Fluke 9100S/725-KIT Hi-Temp Dry-Well and Process Calibrator Kit. Ideal for use in the field or the laboratory, it will test and calibrate almost any process parameter and comes equipped with the dry-block calibrator and the multifunction process calibrator. The versatile design of the kit allows it to work on a large selection of processes to improve the efficiency and accuracy of the workplace.
Features
Fluke 9100S-A Specifications | |
Range | 95 to 707°F (35 to 375°C) |
Accuracy | ±0.25°C at 122°F (50°C) ±0.25°C at 212°F (100°C) ±0.5°C at 707°F (375°C) |
Stability | ±0.07°C at 122°F (50°C) ±0.1°C at 212°F (100°C) ±0.3°C at 707°F (375°C) |
Well-to-Well Uniformity | ±0.2°C with sensors of similar size at equal depths within wells |
Heating Times | 95 to 707°F (35 to 375°C): 9.5 minutes |
Stabilization | 5 minutes |
Cooling Times | 707 to 212°F (375 to 100°C): 14 minutes |
Well Depth | 4" (102 mm) 1⁄16" (1.6 mm) hole in 3.5" (89 mm) deep |
Fluke 725 Specifications | |
Voltage DC | 30 V: 0.02% + 2 counts (upper display) 30 V: 0.02% + 2 counts (lower display) 100 mV: 0.02% + 2 counts -10to 75 mV: 0.025% + 1 count (via TC connector) |
Current DC | 24 mA: 0.02% + 2 counts |
Resistance | 0 to 400 Ω: 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) 401 to 1500 Ω: 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) 1500 to 3200 Ω: 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) |
Frequency | 2 to 1000 CPM: 0.05% + 1 count 1 to 1100 Hz: 0.05% + 1 count 1 to 10 kHz: 0.05% + 1 count Sensitivity: 1 V peak-to-peak-minimum |
Pressure | Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. |
Ramp Functions | Source functions: voltage, current, resistance, frequency, temperature Ramps: slow ramp, fast ramp, 25% step-ramp |
Loop Power Function | Voltage: 24 V Accuracy: 10% Maximum current: 22 mA, short circuit protected |
Step Functions | Source functions: Voltage, current, resistance, frequency, temperature Steps: 25% of range, 100% of range |
Temperature | Operating: 14 to 131°F (-10 to 55°C) Storage: -4 to 159.8°F (-20 to 71°C) |
Dimensions | 5.1 x 9.3 x 2.4" (130 x 236 x 61 mm) |
Weight | 1.43 lbs (0.65 kg) |
Comes in a compact and lightweight design, this handheld dry well is as well simple to use. This unit is ideal for checking RTDs, thermocouples, and small bimetal thermometers in the field. Additionally, this tool handles a full range of probe sizes such as 1⁄16", 1⁄8", 1⁄4", 5⁄32", and 2 wells of 3⁄16".
Easily source and measure a wide variety of process parameters and test many process devices. This unit is capable of measuring and sourcing mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules. Additionally, it features a small and compact design.
Click on a category to view a selection of compatible accessories with the Fluke 9100S/725-KIT Hi-Temp Dry-Well and Process Calibrator Kit.
Fluke 9100S-A Specifications | |
Range | 95 to 707°F (35 to 375°C) |
Accuracy | ±0.25°C at 122°F (50°C) ±0.25°C at 212°F (100°C) ±0.5°C at 707°F (375°C) |
Stability | ±0.07°C at 122°F (50°C) ±0.1°C at 212°F (100°C) ±0.3°C at 707°F (375°C) |
Well-to-Well Uniformity | ±0.2°C with sensors of similar size at equal depths within wells |
Heating Times | 95 to 707°F (35 to 375°C): 9.5 minutes |
Stabilization | 5 minutes |
Cooling Times | 707 to 212°F (375 to 100°C): 14 minutes |
Well Depth | 4" (102 mm) 1⁄16" (1.6 mm) hole in 3.5" (89 mm) deep |
Fluke 725 Specifications | |
Voltage DC | 30 V: 0.02% + 2 counts (upper display) 30 V: 0.02% + 2 counts (lower display) 100 mV: 0.02% + 2 counts -10to 75 mV: 0.025% + 1 count (via TC connector) |
Current DC | 24 mA: 0.02% + 2 counts |
Resistance | 0 to 400 Ω: 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) 401 to 1500 Ω: 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) 1500 to 3200 Ω: 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) |
Frequency | 2 to 1000 CPM: 0.05% + 1 count 1 to 1100 Hz: 0.05% + 1 count 1 to 10 kHz: 0.05% + 1 count Sensitivity: 1 V peak-to-peak-minimum |
Pressure | Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. |
Ramp Functions | Source functions: voltage, current, resistance, frequency, temperature Ramps: slow ramp, fast ramp, 25% step-ramp |
Loop Power Function | Voltage: 24 V Accuracy: 10% Maximum current: 22 mA, short circuit protected |
Step Functions | Source functions: Voltage, current, resistance, frequency, temperature Steps: 25% of range, 100% of range |
Temperature | Operating: 14 to 131°F (-10 to 55°C) Storage: -4 to 159.8°F (-20 to 71°C) |
Dimensions | 5.1 x 9.3 x 2.4" (130 x 236 x 61 mm) |
Weight | 1.43 lbs (0.65 kg) |
Comes in a compact and lightweight design, this handheld dry well is as well simple to use. This unit is ideal for checking RTDs, thermocouples, and small bimetal thermometers in the field. Additionally, this tool handles a full range of probe sizes such as 1⁄16", 1⁄8", 1⁄4", 5⁄32", and 2 wells of 3⁄16".
Easily source and measure a wide variety of process parameters and test many process devices. This unit is capable of measuring and sourcing mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules. Additionally, it features a small and compact design.
Click on a category to view a selection of compatible accessories with the Fluke 9100S/725-KIT Hi-Temp Dry-Well and Process Calibrator Kit.