Built to ensure accuracy and overall quality, this thermal imaging kit offers a quick solution for temperature screening in a variety of environments, including building entrances, airports, factories, and more. It determines surface skin temperature ranging from 93.2 to 102.2°F, based on a thermal image in less than one second.
Built to ensure accuracy and overall quality, this thermal imaging kit offers a quick solution for temperature screening in a variety of environments, including building entrances, airports, factories, and more. It determines surface skin temperature ranging from 93.2 to 102.2°F, based on a thermal image in less than one second.
Discontinued!
This product has been discontinued and is no longer available.
There is no direct replacement, however we recommend the:
Not what you're looking for? Let’s do a search and help you find what you need.
Features
Quick results
With a measurement time of approximately one second, the system minimizes the productivity impact of a temperature screening process. The system is portable and assembles rather simply, enabling the ability for users to carefully select the optimal screening area. Note that to maximize accuracy of the system and adhere to FDA guidance, it conducts temperature screening on an individual basis (e.g., one person at a time).
Accuracy and resolution
When it comes to measuring human body temperature, accuracy is one of the most important attributes. The ±0.25°C accuracy is defined as the difference between actual and expected readings using a secondary blackbody calibration source. When combined with other system uncertainties including stability, long-term drift, uniformity, and uncertainty in the accuracy of the temperature reference source, the combined accuracy of the system is ±0.5°C. It utilizes a 640 x 480 infrared resolution camera, inferring [not inferring, but rather providing] 307,200 pixels of temperature measurements.
For context, this means that when someone is standing at the specified distance from the camera each pixel is measuring a 1mm area on each human face. The system is for initial human temperature measurement only. Any elevated or suspected elevated body temperature measurement must be confirmed with a secondary evaluation method (e.g., non-contact infrared thermometer (NCIT) or clinical grade contact thermometer).
Facial detection
The system utilizes facial detection technology to ensure that the subject is properly positioned and has enough measurement points on the face to accurately measure the body temperature. The device can operate effectively within a range of 3.28 to 4.9' (1 to 1.5 m) from the subject to the camera and by doing so, the 640 x 480 resolution can be optimized, generating a reading in which each pixel that is measured is approximately 1 mm square of the human face.
Consequently, providing measurement and assessment performance in accordance with IEC 80601-2-59. Facial detection technology enables the ability to ensure that temperature measurements of the facial region are actually captured, rather than unrelated items (e.g., a tumbler filled with hot liquid, etc.) that happen to be in the field of view of the thermal camera.
Social distance
The system enables social distancing by having each person move into the measurement area while maintaining the required distance between each person. Additionally, the system can be set up so that the operator is also able to safely practice social distancing as well (e.g., with an operator of the system 6' from the subject, behind a barrier or in another room if desired).
Data privacy
The system is equipped with data capture features applicable to a range of customer preferences. By default, unidentifiable data (i.e., date, time and temperature) is recorded when a subject with an elevated body temperature is identified. If preferred, settings can be adjusted in the software to capture thermal or visible light images at the moment when elevated temperature is identified.
Applications
System Specifications | |
Typical Scan Measurement Time | ≤1 second |
Temperature Range | 93.2 to 102.2°F (34 to 39°C) |
Accuracy | ±0.45°F (0.25°C) |
Languages | English |
Camera and External Shutter | |
IR Resolution | 640 x 480 |
Horizontal/Vertical Field of View (FOV) | 34 x 24° |
Stand | ¼"-20 standard camera tripod mount |
Visible Light Camera Resolution | 5 megapixels |
Spectral Range | 8 to 14 microns |
Dimensions | 10.9 x 4.8 x 8.5" (27.7 x 12.2 x 21.6 cm) |
Weight | 5 lbs (2.5 kg) |
External Temperature Reference Source (ETRS) | |
External Power | 120 V |
Stand | ETRS tripod with adapter |
Dimensions | 14 x 9.5 x 8.5" (356 x 241 x 216 mm) |
Weight | 20 lbs (9.1 kg) |
Software | |
Face Area Detection | Automatic |
Temperature Correction | Automatic |
Alert | On equipment status changes |
Image file format | JPEG |
Environment | |
Ambient Temperature Range (per FDA Guidance and IEC Specifications) | 64 to 75°F (18 to 24°C) |
Operating Humidity | ≤75%, non-condensing |
PC and Display Requirements | |
Resolution | 1920 x 1080 |
Requirements | OS: Windows 10 Processor: i7, 3 GHz or better RAM: 16 GB or more Hard drive: 200 MB for application, more for scanning records (100 KB each) Secondary display requirements (optional for operation): 1920 x 1080 |
Export File Formats | JPEG |
Click on a category to view a selection of compatible accessories with the Fluke FS100 Thermal Body Screener, 93.2 to 102.2°F.
System Specifications | |
Typical Scan Measurement Time | ≤1 second |
Temperature Range | 93.2 to 102.2°F (34 to 39°C) |
Accuracy | ±0.45°F (0.25°C) |
Languages | English |
Camera and External Shutter | |
IR Resolution | 640 x 480 |
Horizontal/Vertical Field of View (FOV) | 34 x 24° |
Stand | ¼"-20 standard camera tripod mount |
Visible Light Camera Resolution | 5 megapixels |
Spectral Range | 8 to 14 microns |
Dimensions | 10.9 x 4.8 x 8.5" (27.7 x 12.2 x 21.6 cm) |
Weight | 5 lbs (2.5 kg) |
External Temperature Reference Source (ETRS) | |
External Power | 120 V |
Stand | ETRS tripod with adapter |
Dimensions | 14 x 9.5 x 8.5" (356 x 241 x 216 mm) |
Weight | 20 lbs (9.1 kg) |
Software | |
Face Area Detection | Automatic |
Temperature Correction | Automatic |
Alert | On equipment status changes |
Image file format | JPEG |
Environment | |
Ambient Temperature Range (per FDA Guidance and IEC Specifications) | 64 to 75°F (18 to 24°C) |
Operating Humidity | ≤75%, non-condensing |
PC and Display Requirements | |
Resolution | 1920 x 1080 |
Requirements | OS: Windows 10 Processor: i7, 3 GHz or better RAM: 16 GB or more Hard drive: 200 MB for application, more for scanning records (100 KB each) Secondary display requirements (optional for operation): 1920 x 1080 |
Export File Formats | JPEG |
Click on a category to view a selection of compatible accessories with the Fluke FS100 Thermal Body Screener, 93.2 to 102.2°F.