Fluke FS100 Thermal Body Screener, 93.2 to 102.2°F

Model: FS100 | UPC: 195112013373

Fluke FS100 Thermal Body Screener, 93.2 to 102.2°F

Model: FS100 | UPC: 195112013373

Built to ensure accuracy and overall quality, this thermal imaging kit offers a quick solution for temperature screening in a variety of environments, including building entrances, airports, factories, and more. It determines surface skin temperature ranging from 93.2 to 102.2°F, based on a thermal image in less than one second.

Built to ensure accuracy and overall quality, this thermal imaging kit offers a quick solution for temperature screening in a variety of environments, including building entrances, airports, factories, and more. It determines surface skin temperature ranging from 93.2 to 102.2°F, based on a thermal image in less than one second.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

FLIR E54 Advanced Thermal Imaging Camera with 24° lens, 320 x 240-

FLIR E54 Advanced Thermal Imaging Camera with 24° lens, 320 x 240

Model: 84512-1201 | Order No: E54

Built to monitor conditions as well as building, electrical, and mechanical inspections, the camera features a 320 × 240 pixel thermal detector, which measures temperatures up to 1202°F (650°C). Additionally, it is quick to set up and comes with FLIR's Thermal Studio Starter.


Planck TC160 ThermaCheck EBT Screening System-

Planck TC160 ThermaCheck EBT Screening System

Model: TC160

An intelligent, dual vision temperature screener equipped with a high-definition visible light camera and infrared thermal imager that provides accurate and rapid skin temperature screening. It is ideal for screening public areas, provides data logging capabilities, and issues alert when persons with elevated skin temperature are present.


Seek Scan Kiosk Kit Temperature Screening Kiosk Conversion Kit-

Seek Scan Kiosk Kit Temperature Screening Kiosk Conversion Kit

Model: Kiosk Acc Kit | Order No: YA-KAA

Convert Any Seek Scan System into a Kiosk. Easily turn your Seek thermal imaging system into a temperature screening kiosk with the Seek Scan Kiosk Kit. Screen for elevated body temperature with this professional, self-contained kiosk that is perfect for any office lobby and facility. This kit contains two aluminum stands, a 10", Windows tablet, a sticker decal kit, and all necessary cables. Seek Scan is sold separately.


Not what you're looking for? Let’s do a search and help you find what you need.


Fluke FS100 Offers

Features

  • Measurement time of approximately one second
  • Combined accuracy of the system is ±0.5°C
  • Can reduce the need for resources related to temperature screening services
  • Utilizes facial detection technology to ensure that the subject is properly positioned
  • Resolution of 640 x 480 with the infrared camera
  • External Temperature Reference Source (ETRS): an external temperature reference source, allowing for traceability and accuracy of infrared body temperature measurements by continuously benchmarking against a known, stable temperature surface in the camera's field of view
  • Ambient temperature and relative humidity

Quick results

With a measurement time of approximately one second, the system minimizes the productivity impact of a temperature screening process. The system is portable and assembles rather simply, enabling the ability for users to carefully select the optimal screening area. Note that to maximize accuracy of the system and adhere to FDA guidance, it conducts temperature screening on an individual basis (e.g., one person at a time).

Accuracy and resolution

When it comes to measuring human body temperature, accuracy is one of the most important attributes. The ±0.25°C accuracy is defined as the difference between actual and expected readings using a secondary blackbody calibration source. When combined with other system uncertainties including stability, long-term drift, uniformity, and uncertainty in the accuracy of the temperature reference source, the combined accuracy of the system is ±0.5°C. It utilizes a 640 x 480 infrared resolution camera, inferring [not inferring, but rather providing] 307,200 pixels of temperature measurements.

For context, this means that when someone is standing at the specified distance from the camera each pixel is measuring a 1mm area on each human face. The system is for initial human temperature measurement only. Any elevated or suspected elevated body temperature measurement must be confirmed with a secondary evaluation method (e.g., non-contact infrared thermometer (NCIT) or clinical grade contact thermometer).

Facial detection

The system utilizes facial detection technology to ensure that the subject is properly positioned and has enough measurement points on the face to accurately measure the body temperature. The device can operate effectively within a range of 3.28 to 4.9' (1 to 1.5 m) from the subject to the camera and by doing so, the 640 x 480 resolution can be optimized, generating a reading in which each pixel that is measured is approximately 1 mm square of the human face.

Consequently, providing measurement and assessment performance in accordance with IEC 80601-2-59. Facial detection technology enables the ability to ensure that temperature measurements of the facial region are actually captured, rather than unrelated items (e.g., a tumbler filled with hot liquid, etc.) that happen to be in the field of view of the thermal camera.

Social distance

The system enables social distancing by having each person move into the measurement area while maintaining the required distance between each person. Additionally, the system can be set up so that the operator is also able to safely practice social distancing as well (e.g., with an operator of the system 6' from the subject, behind a barrier or in another room if desired).

Data privacy

The system is equipped with data capture features applicable to a range of customer preferences. By default, unidentifiable data (i.e., date, time and temperature) is recorded when a subject with an elevated body temperature is identified. If preferred, settings can be adjusted in the software to capture thermal or visible light images at the moment when elevated temperature is identified.

Applications

  • Human body temperature screening

Fluke FS100 Specifications

System Specifications
Typical Scan Measurement Time ≤1 second
Temperature Range 93.2 to 102.2°F (34 to 39°C)
Accuracy ±0.45°F (0.25°C)
Languages English
Camera and External Shutter
IR Resolution 640 x 480
Horizontal/Vertical Field of View (FOV) 34 x 24°
Stand ¼"-20 standard camera tripod mount
Visible Light Camera Resolution 5 megapixels
Spectral Range 8 to 14 microns
Dimensions 10.9 x 4.8 x 8.5" (27.7 x 12.2 x 21.6 cm)
Weight 5 lbs (2.5 kg)
External Temperature Reference Source (ETRS)
External Power 120 V
Stand ETRS tripod with adapter
Dimensions 14 x 9.5 x 8.5" (356 x 241 x 216 mm)
Weight 20 lbs (9.1 kg)
Software
Face Area Detection Automatic
Temperature Correction Automatic
Alert On equipment status changes
Image file format JPEG
Environment
Ambient Temperature Range (per FDA Guidance and IEC Specifications) 64 to 75°F (18 to 24°C)
Operating Humidity ≤75%, non-condensing
PC and Display Requirements
Resolution 1920 x 1080
Requirements OS: Windows 10
Processor: i7, 3 GHz or better
RAM: 16 GB or more
Hard drive: 200 MB for application, more for scanning records (100 KB each)
Secondary display requirements (optional for operation): 1920 x 1080
Export File Formats JPEG
Click here for complete specifications on the Fluke FS100

What's included with the Fluke FS100

  • External Temperature Reference Source (ETRS)
  • Thermal Camera
  • 2 x Non-Reflective Screens
  • ETRS Stand
  • Tripod for Thermal Camera
  • Temperature and Relative Humidity Data Logger and AC Adapters
  • Tripod-Camera Adapter
  • USB Hub
  • USB Cables
  • USB Extension Cables
  • RS232-USB Adapter for ETRS
  • 2 x Power Strips

Click on a category to view a selection of compatible accessories with the Fluke FS100 Thermal Body Screener, 93.2 to 102.2°F.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke FS100 Thermal Body Screener, 93.2 to 102.2°F

Customer Reviews for the Fluke FS100

Fluke FS100 Offers

Features

  • Measurement time of approximately one second
  • Combined accuracy of the system is ±0.5°C
  • Can reduce the need for resources related to temperature screening services
  • Utilizes facial detection technology to ensure that the subject is properly positioned
  • Resolution of 640 x 480 with the infrared camera
  • External Temperature Reference Source (ETRS): an external temperature reference source, allowing for traceability and accuracy of infrared body temperature measurements by continuously benchmarking against a known, stable temperature surface in the camera's field of view
  • Ambient temperature and relative humidity

Quick results

With a measurement time of approximately one second, the system minimizes the productivity impact of a temperature screening process. The system is portable and assembles rather simply, enabling the ability for users to carefully select the optimal screening area. Note that to maximize accuracy of the system and adhere to FDA guidance, it conducts temperature screening on an individual basis (e.g., one person at a time).

Accuracy and resolution

When it comes to measuring human body temperature, accuracy is one of the most important attributes. The ±0.25°C accuracy is defined as the difference between actual and expected readings using a secondary blackbody calibration source. When combined with other system uncertainties including stability, long-term drift, uniformity, and uncertainty in the accuracy of the temperature reference source, the combined accuracy of the system is ±0.5°C. It utilizes a 640 x 480 infrared resolution camera, inferring [not inferring, but rather providing] 307,200 pixels of temperature measurements.

For context, this means that when someone is standing at the specified distance from the camera each pixel is measuring a 1mm area on each human face. The system is for initial human temperature measurement only. Any elevated or suspected elevated body temperature measurement must be confirmed with a secondary evaluation method (e.g., non-contact infrared thermometer (NCIT) or clinical grade contact thermometer).

Facial detection

The system utilizes facial detection technology to ensure that the subject is properly positioned and has enough measurement points on the face to accurately measure the body temperature. The device can operate effectively within a range of 3.28 to 4.9' (1 to 1.5 m) from the subject to the camera and by doing so, the 640 x 480 resolution can be optimized, generating a reading in which each pixel that is measured is approximately 1 mm square of the human face.

Consequently, providing measurement and assessment performance in accordance with IEC 80601-2-59. Facial detection technology enables the ability to ensure that temperature measurements of the facial region are actually captured, rather than unrelated items (e.g., a tumbler filled with hot liquid, etc.) that happen to be in the field of view of the thermal camera.

Social distance

The system enables social distancing by having each person move into the measurement area while maintaining the required distance between each person. Additionally, the system can be set up so that the operator is also able to safely practice social distancing as well (e.g., with an operator of the system 6' from the subject, behind a barrier or in another room if desired).

Data privacy

The system is equipped with data capture features applicable to a range of customer preferences. By default, unidentifiable data (i.e., date, time and temperature) is recorded when a subject with an elevated body temperature is identified. If preferred, settings can be adjusted in the software to capture thermal or visible light images at the moment when elevated temperature is identified.

Applications

  • Human body temperature screening

Fluke FS100 Specifications

System Specifications
Typical Scan Measurement Time ≤1 second
Temperature Range 93.2 to 102.2°F (34 to 39°C)
Accuracy ±0.45°F (0.25°C)
Languages English
Camera and External Shutter
IR Resolution 640 x 480
Horizontal/Vertical Field of View (FOV) 34 x 24°
Stand ¼"-20 standard camera tripod mount
Visible Light Camera Resolution 5 megapixels
Spectral Range 8 to 14 microns
Dimensions 10.9 x 4.8 x 8.5" (27.7 x 12.2 x 21.6 cm)
Weight 5 lbs (2.5 kg)
External Temperature Reference Source (ETRS)
External Power 120 V
Stand ETRS tripod with adapter
Dimensions 14 x 9.5 x 8.5" (356 x 241 x 216 mm)
Weight 20 lbs (9.1 kg)
Software
Face Area Detection Automatic
Temperature Correction Automatic
Alert On equipment status changes
Image file format JPEG
Environment
Ambient Temperature Range (per FDA Guidance and IEC Specifications) 64 to 75°F (18 to 24°C)
Operating Humidity ≤75%, non-condensing
PC and Display Requirements
Resolution 1920 x 1080
Requirements OS: Windows 10
Processor: i7, 3 GHz or better
RAM: 16 GB or more
Hard drive: 200 MB for application, more for scanning records (100 KB each)
Secondary display requirements (optional for operation): 1920 x 1080
Export File Formats JPEG
Click here for complete specifications on the Fluke FS100

What's included with the Fluke FS100

  • External Temperature Reference Source (ETRS)
  • Thermal Camera
  • 2 x Non-Reflective Screens
  • ETRS Stand
  • Tripod for Thermal Camera
  • Temperature and Relative Humidity Data Logger and AC Adapters
  • Tripod-Camera Adapter
  • USB Hub
  • USB Cables
  • USB Extension Cables
  • RS232-USB Adapter for ETRS
  • 2 x Power Strips

Click on a category to view a selection of compatible accessories with the Fluke FS100 Thermal Body Screener, 93.2 to 102.2°F.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke FS100 Thermal Body Screener, 93.2 to 102.2°F

Customer Reviews for the Fluke FS100

More Fluke Products

Between March 11 and June 30, 2024 spend $500 or more and get a free Fluke tool or bundle with your purchase.
Calibration Lab