For use with digital multimeters, power quality analyzers, and portable oscilloscopes, this current clamp allows users to take accurate current measurements without breaking electric circuits. Additionally, it measures up to 400 A AC.
For use with digital multimeters, power quality analyzers, and portable oscilloscopes, this current clamp allows users to take accurate current measurements without breaking electric circuits. Additionally, it measures up to 400 A AC.
Features
Compatible with
Electrical Specifications | |
Nominal Current Range | 40 A Range: 0.5 to 40 A 400 A Range: 5 to 400 A |
Basic Accuracy | 40 A Range: 2% + 0.015 A (45 to 400 Hz) 400 A Range: 2% + 0.04 A (45-400 Hz) |
Phase Shift 40 A Range | 0.5 to 1 A: Unspecified 1 to 5 A: 4° 5 to 10 A: 3° 10 to 20 A: 3° 20 to 40 A: 2° 40 to 400 A: NA |
Phase Shift 400 A Range | 0.5 to 1 A: NA 1 to 5 A: NA 5 to 10 A: Unspecified 10 to 20 A: 2° 20 to 40 A: 2° 40 to 400 A: 1.5° |
Typical Bandwidth | 40 A Range: 5 to 10 kHz 400 A Range: 5 to 10 kHz |
Output Level(s) | 40 A Range: 10 mV/A 400 A Range: 1 mV/A |
Crest Factor | 40 A Range: ≤3 400 A Range: ≤3 to 300 A, ≤2.5 to 400 A |
Mechanical and General Specifications | |
Maximum Conductor Size | 1.25" (32 mm) |
Output Cable Length | 8.2' (2.5 m) |
BNC Adapter | Yes |
Dimensions | 5.9 x 2.7 x 1.2" (150 x 70 x 30 mm) |
Weight | 0.25 lb (114 g) |
Safety Specifications | |
Safety | CAT IV, 600 V, CAT III, 1000 V |
Maximum Non-Destructive Current | 1000 V AC |
Click on a category to view a selection of compatible accessories with the Fluke i400S AC Current Clamp.
Electrical Specifications | |
Nominal Current Range | 40 A Range: 0.5 to 40 A 400 A Range: 5 to 400 A |
Basic Accuracy | 40 A Range: 2% + 0.015 A (45 to 400 Hz) 400 A Range: 2% + 0.04 A (45-400 Hz) |
Phase Shift 40 A Range | 0.5 to 1 A: Unspecified 1 to 5 A: 4° 5 to 10 A: 3° 10 to 20 A: 3° 20 to 40 A: 2° 40 to 400 A: NA |
Phase Shift 400 A Range | 0.5 to 1 A: NA 1 to 5 A: NA 5 to 10 A: Unspecified 10 to 20 A: 2° 20 to 40 A: 2° 40 to 400 A: 1.5° |
Typical Bandwidth | 40 A Range: 5 to 10 kHz 400 A Range: 5 to 10 kHz |
Output Level(s) | 40 A Range: 10 mV/A 400 A Range: 1 mV/A |
Crest Factor | 40 A Range: ≤3 400 A Range: ≤3 to 300 A, ≤2.5 to 400 A |
Mechanical and General Specifications | |
Maximum Conductor Size | 1.25" (32 mm) |
Output Cable Length | 8.2' (2.5 m) |
BNC Adapter | Yes |
Dimensions | 5.9 x 2.7 x 1.2" (150 x 70 x 30 mm) |
Weight | 0.25 lb (114 g) |
Safety Specifications | |
Safety | CAT IV, 600 V, CAT III, 1000 V |
Maximum Non-Destructive Current | 1000 V AC |
Click on a category to view a selection of compatible accessories with the Fluke i400S AC Current Clamp.