Flexible 24" 6000A AC current probe with BNC terminated lead.
Flexible 24" 6000A AC current probe with BNC terminated lead.
Electrical Characteristics | |
Current Ranges | 60 A / 600 A / 6000 A ACRMS |
Output Sensitivity (AC coupled) | 50 mV /5mV / 0.5mV per A |
Load Impedance | 100 kOhm minimum |
Accuracy (at +25°C) | ±1% of range (45 - 65 Hz) |
Linearity (10% to 100% of range) | ±0.2% of reading |
Noise | 8mV ACRMS (60 A) 2 mV ACRMS (600/6000A) |
Frequency Range | 10 Hz to 50 kHz (- 3 dB) |
Phase Error | < ±1° (45 - 65Hz), ±10° (at 20 kHz) |
Position Sensitivity (with cable > 25mm from the coupling) | ±2% of range |
External field (with cable > 200mm from the head) | ±1% of range |
Power Supply | 2 x AA MN 1500 LR6 alkaline 400 Hours, low battery indicator or dedicated ext power supply |
Temperature Coefficient | ±0.08% of reading per C |
Working Voltage (see Safety Standards section) | 600 V ACRMS or DC |
General Characteristics | |||
Head Cable length-(double insulated) |
| ||
Head Cable Diameter |
| ||
Head Bend Radius |
| ||
Cable length (head to electronics) |
| ||
Output Connection |
| ||
Operating Temperature Range |
| ||
Storage Temperature Range |
| ||
Operating Humidity |
| ||
Weight |
|
Safety Standards | |||
BS EN 61010 |
| ||
BS EN 61010 |
| ||
BS EN 61010 |
| ||
600VRMS, Category III, Pollution Degree 2 | |||
Note |
| ||
EMC Standards |
|
Click on a category to view a selection of compatible accessories with the Fluke i6000s Flex-24 AC Current Probe.
Electrical Characteristics | |
Current Ranges | 60 A / 600 A / 6000 A ACRMS |
Output Sensitivity (AC coupled) | 50 mV /5mV / 0.5mV per A |
Load Impedance | 100 kOhm minimum |
Accuracy (at +25°C) | ±1% of range (45 - 65 Hz) |
Linearity (10% to 100% of range) | ±0.2% of reading |
Noise | 8mV ACRMS (60 A) 2 mV ACRMS (600/6000A) |
Frequency Range | 10 Hz to 50 kHz (- 3 dB) |
Phase Error | < ±1° (45 - 65Hz), ±10° (at 20 kHz) |
Position Sensitivity (with cable > 25mm from the coupling) | ±2% of range |
External field (with cable > 200mm from the head) | ±1% of range |
Power Supply | 2 x AA MN 1500 LR6 alkaline 400 Hours, low battery indicator or dedicated ext power supply |
Temperature Coefficient | ±0.08% of reading per C |
Working Voltage (see Safety Standards section) | 600 V ACRMS or DC |
General Characteristics | |||
Head Cable length-(double insulated) |
| ||
Head Cable Diameter |
| ||
Head Bend Radius |
| ||
Cable length (head to electronics) |
| ||
Output Connection |
| ||
Operating Temperature Range |
| ||
Storage Temperature Range |
| ||
Operating Humidity |
| ||
Weight |
|
Safety Standards | |||
BS EN 61010 |
| ||
BS EN 61010 |
| ||
BS EN 61010 |
| ||
600VRMS, Category III, Pollution Degree 2 | |||
Note |
| ||
EMC Standards |
|
Click on a category to view a selection of compatible accessories with the Fluke i6000s Flex-24 AC Current Probe.