Fluke Networks LinkIQ Industrial Ethernet Cable and Network Test Kit, 10 Gb/s, 1000'

Model: LIQ-KIT-IE | UPC: 754082152194

Fluke Networks LinkIQ Industrial Ethernet Cable and Network Test Kit, 10 Gb/s, 1000'

Model: LIQ-KIT-IE | UPC: 754082152194

Verify ethernet cable performance up to 10 Gb/s with this industrial ethernet cable and network test kit to solve network connectivity problems. In addition, this kit includes a remote ID, four patch cords, an AC charger, a universal coupler, a modular adapter, a probe, a USB-C to USB-A cable, a hanging strap, and a carrying case.

Verify ethernet cable performance up to 10 Gb/s with this industrial ethernet cable and network test kit to solve network connectivity problems. In addition, this kit includes a remote ID, four patch cords, an AC charger, a universal coupler, a modular adapter, a probe, a USB-C to USB-A cable, a hanging strap, and a carrying case.

Sale Price $4108.74 USD
Regular Price $4324.99 USD
Availability 5 to 6 Weeks
Quantity

Fluke Networks LIQ-KIT-IE Offers

Provide complete documentation with this cable and network tester advanced kit capable of exporting report data to a PC to manage results and print reports. Additionally, this kit can identify switch information such as switch data rate, switch name, IP address, port number, and VLAN.

Features

  • Validate cable performance to support Ethernet/IP, PROFINET, EtherCAT
  • Identifies miswired and split pairs on RJ45, M12X, M12D, and M8D terminated cables
  • Identify connected switch information (switch data rate, switch name, IP address, port number, and VLAN)
  • Install and troubleshoot PoE devices via switch negotiation and PoE load test
  • Document your work through LinkWare™ PC
  • Generates analog or digital tones compatible with the IntelliTone™ probe to assist in locating cables in a wall or telecommunications room
  • Blink port light on switch to help identify the connected switch port
  • Compatible with MicroScanner™ PoE remote identifiers for ethernet outlet identification
  • Touch Sensitive gesture based display
  • Rechargeable Li-ion battery
  • Easy feature and network testing upgrades via USB-C via LinkWare™ PC LIQ100 includes mainframe and accessories
  • Charging via standard USBC port
  • Detect the PoE class (1 to 8) and power, and perform a load test
  • Test connectivity to TCP/IP network through IP configuration and ping
  • Cable diagnostics including length plus IntelliTone™, remotes 2 to 8

Applications

  • Cable diagnostics
  • Network connectivity problems

Fluke Networks LIQ-KIT-IE Specifications

Diagnostic Protocols Link Layer Discovery Protocol (LLDP)
Cisco Discovery Protocol (CDP)
Fast Link Pulses (FLP)
Nearest Device Diagnostics, (If Available Through Diagnostic Protocols) Switch name
Port number
VLAN name
Advertised data rates
Advertised duplex
Power Over Ethernet Compatibility IEEE 802.3af/at (SW v1.0)
Hardware negotiation with signature resistance
Software negotiation with LLDP/CDP
Power Over Ethernet Diagnostics Advertised power class (1 to 4) (SW v1.0)
Advertised available power
Powered pairs
Diagnostics for both single and dual signatures
Power Over Ethernet Measurements Loaded voltage (V)
Loaded power (W)
Port Blink Blink the light of the connected port
Test Port Shielded 8-pin modular jack accepts 8-pin modular (RJ45) plugs
Commissioning Autotests 10GBASE-T, 5GBASE-T, 2.5GBASE-T, 1000BASE-T, 100BASE-TX, 10BASE-T, Wire map Only
Test Speed: 6 seconds for lengths <229.65' (70 m)
Cable Types Balanced twisted-pair cabling
Unshielded twisted-pair
Screened twisted-pair
2-pair and/or 4-pair
Wire Map-Only Tests Document wire map
Length of each pair
Diagnose split pairs
User selectable T568A or T568B
User selectable crossover settings (straight through, halfcrossover, full-crossover)
Test speed: 1 second for lengths <393.7' (120 m)
Length (Maximum) 1000' (305 m)
Nominal Velocity of Propagation (NVP) User settable
Tone Generator Generates digital tones compatible with Fluke Networks IntelliTone probe
Generates analog tones compatible with general analog probes.
Remote ID Locators Use remote ID terminations to identify up to 7 unique ports or office outlets
Drop 3.28' (1 m) drop, 6 sides
Vibration Random, 2 g, 5 to 500 Hz
Operating Altitude 13,123.36' (4000 m)
10,498.69' (3200 m) with AC adapter
Operating Relative Humidity 0 to 90%, 32 to 95°F (0 to 35°C)
0 to 70%, 95 to 113°F (35 to 45°C)
Temperature Operating: 32 to 113°F (0 to 45°C)
Storage: -4 to 1122°F (-20 to 50°C)
Display 800 x 480 color capacitive multi-touch
Host Interface USB type C
Power Adapter Input: 100 to 240 V AC ±10%, 50/60 Hz
Output: 15 V DC, 2 A maximum; Class II
Battery Type: Lithium-ion, 3.6 V, 6400 mAh
Life: 8 hours typical
Charge time: 4.5 hours
Charging temperature range: 32 to 104°F (0 to 40°C)
Dimensions 8.5 x 4.5" (21.59 x 11.43 cm)
Weight 1 lbs, 6 oz (624 g)
Click here for complete specifications on the Fluke Networks LIQ-KIT-IE

What's included with the Fluke Networks LIQ-KIT-IE

  • Cable and Network Tester
  • Remote ID
  • 4 x Patch Cords
  • USB-C to USB-A cable
  • Universal Coupler
  • Modular Adapter
  • Probe
  • Hanging Strap
  • AC Charger
  • Carrying Case
  • Quick Reference Guide
  • One-Year Warranty

Click on a category to view a selection of compatible accessories with the Fluke Networks LinkIQ Industrial Ethernet Cable and Network Test Kit, 10 Gb/s, 1000'.

Fluke Networks REMOTEID-1/Wiremapper for LinkIQ REMOTEID-1
Use the remote IDs for ethernet outlet identification and analyze each wire's length, pairing, and cable performance up to 10Gb/s for in-depth and reliable cable testing.




Fluke Networks REMOTEID-KIT Remote ID Kit for the LinkIQ and Microscanner PoE REMOTEID-KIT
Especially useful for identifying ethernet outlets, unique ports, or office outlets, these remote ID locators analyze wire length, pairing, and cable performance up to 10Gb/s for in-depth, reliable cable testing. Furthermore, this kit has six remote IDs to identify multiple wire map faults simultaneously.




Fluke Networks MS-IE-ADAPTER SET Industrial Ethernet Adapter Set MS-IE-ADAPTER SET
Use the Industrial Ethernet Remote Adapter to create a complete wire map of the cable pairs and identify miswired and split pairs on RJ45, M12X, M12D, and M8D terminated cables. Compatible with MicroScanner2, MicroScanner PoE, and LinkIQ, the Industrial Ethernet Adapter is versatile and reliable.




Ask a question about Fluke Networks LinkIQ Industrial Ethernet Cable and Network Test Kit, 10 Gb/s, 1000'

Customer Reviews for the Fluke Networks LIQ-KIT-IE

Fluke Networks LIQ-KIT-IE Offers

Provide complete documentation with this cable and network tester advanced kit capable of exporting report data to a PC to manage results and print reports. Additionally, this kit can identify switch information such as switch data rate, switch name, IP address, port number, and VLAN.

Features

  • Validate cable performance to support Ethernet/IP, PROFINET, EtherCAT
  • Identifies miswired and split pairs on RJ45, M12X, M12D, and M8D terminated cables
  • Identify connected switch information (switch data rate, switch name, IP address, port number, and VLAN)
  • Install and troubleshoot PoE devices via switch negotiation and PoE load test
  • Document your work through LinkWare™ PC
  • Generates analog or digital tones compatible with the IntelliTone™ probe to assist in locating cables in a wall or telecommunications room
  • Blink port light on switch to help identify the connected switch port
  • Compatible with MicroScanner™ PoE remote identifiers for ethernet outlet identification
  • Touch Sensitive gesture based display
  • Rechargeable Li-ion battery
  • Easy feature and network testing upgrades via USB-C via LinkWare™ PC LIQ100 includes mainframe and accessories
  • Charging via standard USBC port
  • Detect the PoE class (1 to 8) and power, and perform a load test
  • Test connectivity to TCP/IP network through IP configuration and ping
  • Cable diagnostics including length plus IntelliTone™, remotes 2 to 8

Applications

  • Cable diagnostics
  • Network connectivity problems

Fluke Networks LIQ-KIT-IE Specifications

Diagnostic Protocols Link Layer Discovery Protocol (LLDP)
Cisco Discovery Protocol (CDP)
Fast Link Pulses (FLP)
Nearest Device Diagnostics, (If Available Through Diagnostic Protocols) Switch name
Port number
VLAN name
Advertised data rates
Advertised duplex
Power Over Ethernet Compatibility IEEE 802.3af/at (SW v1.0)
Hardware negotiation with signature resistance
Software negotiation with LLDP/CDP
Power Over Ethernet Diagnostics Advertised power class (1 to 4) (SW v1.0)
Advertised available power
Powered pairs
Diagnostics for both single and dual signatures
Power Over Ethernet Measurements Loaded voltage (V)
Loaded power (W)
Port Blink Blink the light of the connected port
Test Port Shielded 8-pin modular jack accepts 8-pin modular (RJ45) plugs
Commissioning Autotests 10GBASE-T, 5GBASE-T, 2.5GBASE-T, 1000BASE-T, 100BASE-TX, 10BASE-T, Wire map Only
Test Speed: 6 seconds for lengths <229.65' (70 m)
Cable Types Balanced twisted-pair cabling
Unshielded twisted-pair
Screened twisted-pair
2-pair and/or 4-pair
Wire Map-Only Tests Document wire map
Length of each pair
Diagnose split pairs
User selectable T568A or T568B
User selectable crossover settings (straight through, halfcrossover, full-crossover)
Test speed: 1 second for lengths <393.7' (120 m)
Length (Maximum) 1000' (305 m)
Nominal Velocity of Propagation (NVP) User settable
Tone Generator Generates digital tones compatible with Fluke Networks IntelliTone probe
Generates analog tones compatible with general analog probes.
Remote ID Locators Use remote ID terminations to identify up to 7 unique ports or office outlets
Drop 3.28' (1 m) drop, 6 sides
Vibration Random, 2 g, 5 to 500 Hz
Operating Altitude 13,123.36' (4000 m)
10,498.69' (3200 m) with AC adapter
Operating Relative Humidity 0 to 90%, 32 to 95°F (0 to 35°C)
0 to 70%, 95 to 113°F (35 to 45°C)
Temperature Operating: 32 to 113°F (0 to 45°C)
Storage: -4 to 1122°F (-20 to 50°C)
Display 800 x 480 color capacitive multi-touch
Host Interface USB type C
Power Adapter Input: 100 to 240 V AC ±10%, 50/60 Hz
Output: 15 V DC, 2 A maximum; Class II
Battery Type: Lithium-ion, 3.6 V, 6400 mAh
Life: 8 hours typical
Charge time: 4.5 hours
Charging temperature range: 32 to 104°F (0 to 40°C)
Dimensions 8.5 x 4.5" (21.59 x 11.43 cm)
Weight 1 lbs, 6 oz (624 g)
Click here for complete specifications on the Fluke Networks LIQ-KIT-IE

What's included with the Fluke Networks LIQ-KIT-IE

  • Cable and Network Tester
  • Remote ID
  • 4 x Patch Cords
  • USB-C to USB-A cable
  • Universal Coupler
  • Modular Adapter
  • Probe
  • Hanging Strap
  • AC Charger
  • Carrying Case
  • Quick Reference Guide
  • One-Year Warranty

Click on a category to view a selection of compatible accessories with the Fluke Networks LinkIQ Industrial Ethernet Cable and Network Test Kit, 10 Gb/s, 1000'.

Fluke Networks REMOTEID-1/Wiremapper for LinkIQ REMOTEID-1
Use the remote IDs for ethernet outlet identification and analyze each wire's length, pairing, and cable performance up to 10Gb/s for in-depth and reliable cable testing.




Fluke Networks REMOTEID-KIT Remote ID Kit for the LinkIQ and Microscanner PoE REMOTEID-KIT
Especially useful for identifying ethernet outlets, unique ports, or office outlets, these remote ID locators analyze wire length, pairing, and cable performance up to 10Gb/s for in-depth, reliable cable testing. Furthermore, this kit has six remote IDs to identify multiple wire map faults simultaneously.




Fluke Networks MS-IE-ADAPTER SET Industrial Ethernet Adapter Set MS-IE-ADAPTER SET
Use the Industrial Ethernet Remote Adapter to create a complete wire map of the cable pairs and identify miswired and split pairs on RJ45, M12X, M12D, and M8D terminated cables. Compatible with MicroScanner2, MicroScanner PoE, and LinkIQ, the Industrial Ethernet Adapter is versatile and reliable.




Ask a question about Fluke Networks LinkIQ Industrial Ethernet Cable and Network Test Kit, 10 Gb/s, 1000'

Customer Reviews for the Fluke Networks LIQ-KIT-IE

More Fluke Networks Products

Calibration Lab