Fluke PRV240 Proving Unit, 240V

Model: PRV240 | UPC: 095969772983

Fluke PRV240 Proving Unit, 240V

Model: PRV240 | UPC: 095969772983

The portable, pocket-sized, battery-powered voltage source is unique because it sources stable AC/DC voltages for both LoZ and HiZ instruments. Works with multimeters, clamp meters, voltage testers, and two pole testers.

The portable, pocket-sized, battery-powered voltage source is unique because it sources stable AC/DC voltages for both LoZ and HiZ instruments. Works with multimeters, clamp meters, voltage testers, and two pole testers.

Your Price $199.99 USD
Availability 1 in Stock
Quantity

Traceable In-House Calibration Certificate for your PRV240 Proving Unit

Traceable In-House Calibration Certificate for your PRV240 Proving Unit

Fluke PRV240 Offers

Reduces the risk of shock and arc flash by removing unnecessary exposure to a potentially hazardous electrical environment while verifying the functionality of test tools before and after absence or presence of voltage is checked.

Features

  • Sources both AC and DC steady-state voltage - supplies 240 V DC/AC
  • A single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool
  • Compatible with both high impedance or low impedance multimeters, clamp meters or two pole testers
  • Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact
  • Long battery life - 5,000 tests per set of four AA batteries

Test Before Touch

Provides a safe method to verify that your electrical test tool is operating properly before you conduct further tests. The concept of "Test Before Touch" (TBT) or three point test method involves testing your meter against a known live source before and after the actual measurement. This sequence verifies that your test tool is operating properly during the actual measurement.

Designed for safety and compliance

Safe and easy method for verifying proper operation of your test tool before attempting to test for either an energized source or a de-energized source without the need for cumbersome PPE, or in cases where no known voltage source is available. Your environment may still require minimal PPE such as hard, safety glasses or earplugs when using a proving unit.

Fluke PRV240 Specifications

Output voltage: 240 V AC RMS or DC ±10 % ≥1 MΩ
Output voltage: LoZ >3 kΩ load 60 V AC typical; 50 V AC RMS minimum
LED power indicator Turns on when output voltage is present
Battery 4 x AA Alkaline batteries NEDA (24 A IEC LR03)
Battery life 5000 (5-second duration) test cycles with >1 MΩ load, 300 tests minimum with >3 kΩ load
Operating temperature -10 to +50 °C
Operating humidity 0 % to 90 % (0 to 35 °C)
Operating altitude 2000 m
Dimensions 11.7 cm x 7.4 cm x 2.8 cm (4.6 in x 2.9 in x 1.1 in), Pollution Degree 2
Weight 0.23 kg (8 oz) includes batteries
Safety IEC61010-1, IEC61010-2-030
Certification CSA-CUS, CE
Click here for complete specifications on the Fluke PRV240

What's included with the Fluke PRV240

  • Fluke PRV240 Proving Unit
  • TPAK Magnetic hanging strap
  • AA Batteries (x4)
  • Instruction Sheet

Webinar: EVSE Safety Maintenance with Fluke


In recent years, more people are opting for greener solutions to minimize environmental damage, which has led to an increased demand for environmentally safe solutions such as electric vehicles. Naturally, this has led to an increase in the installation of EV charging stations, but also the risks for technicians. In 2020, there were 126 fatal and 2200 non-fatal electrical injuries. Many of these are caused when technicians are exposed to hazardous voltage and arc faults that could cause shock and fire hazards due to a lack of understanding of proper EVSE installation and maintenance. Considering that EVSEs have a high rate of failure, estimated at 30 to 50% (SAE), reliability is essential when building EV infrastructure and gaining user acceptance.

Webinar: Electrical Equipment Safety with Fluke


When safety is on top of mind, everyone benefits. Ensuring that your facility employs the best workplace practices, test tool standards, and ratings, and considers the dangers and causes of incidents will make for a safer work environment. Taking steps to improve these aspects will allow you to enjoy benefits, such as increased productivity and reduced assets-related and accident-related costs. Many tools can help you improve safety by testing, maintaining, monitoring, or troubleshooting live electrical equipment.

Click on a category to view a selection of compatible accessories with the Fluke PRV240 Proving Unit, 240V.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke PRV240 Proving Unit, 240V

Customer Reviews for the Fluke PRV240

Fluke PRV240 Offers

Reduces the risk of shock and arc flash by removing unnecessary exposure to a potentially hazardous electrical environment while verifying the functionality of test tools before and after absence or presence of voltage is checked.

Features

  • Sources both AC and DC steady-state voltage - supplies 240 V DC/AC
  • A single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool
  • Compatible with both high impedance or low impedance multimeters, clamp meters or two pole testers
  • Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact
  • Long battery life - 5,000 tests per set of four AA batteries

Test Before Touch

Provides a safe method to verify that your electrical test tool is operating properly before you conduct further tests. The concept of "Test Before Touch" (TBT) or three point test method involves testing your meter against a known live source before and after the actual measurement. This sequence verifies that your test tool is operating properly during the actual measurement.

Designed for safety and compliance

Safe and easy method for verifying proper operation of your test tool before attempting to test for either an energized source or a de-energized source without the need for cumbersome PPE, or in cases where no known voltage source is available. Your environment may still require minimal PPE such as hard, safety glasses or earplugs when using a proving unit.

Fluke PRV240 Specifications

Output voltage: 240 V AC RMS or DC ±10 % ≥1 MΩ
Output voltage: LoZ >3 kΩ load 60 V AC typical; 50 V AC RMS minimum
LED power indicator Turns on when output voltage is present
Battery 4 x AA Alkaline batteries NEDA (24 A IEC LR03)
Battery life 5000 (5-second duration) test cycles with >1 MΩ load, 300 tests minimum with >3 kΩ load
Operating temperature -10 to +50 °C
Operating humidity 0 % to 90 % (0 to 35 °C)
Operating altitude 2000 m
Dimensions 11.7 cm x 7.4 cm x 2.8 cm (4.6 in x 2.9 in x 1.1 in), Pollution Degree 2
Weight 0.23 kg (8 oz) includes batteries
Safety IEC61010-1, IEC61010-2-030
Certification CSA-CUS, CE
Click here for complete specifications on the Fluke PRV240

What's included with the Fluke PRV240

  • Fluke PRV240 Proving Unit
  • TPAK Magnetic hanging strap
  • AA Batteries (x4)
  • Instruction Sheet

Webinar: EVSE Safety Maintenance with Fluke


In recent years, more people are opting for greener solutions to minimize environmental damage, which has led to an increased demand for environmentally safe solutions such as electric vehicles. Naturally, this has led to an increase in the installation of EV charging stations, but also the risks for technicians. In 2020, there were 126 fatal and 2200 non-fatal electrical injuries. Many of these are caused when technicians are exposed to hazardous voltage and arc faults that could cause shock and fire hazards due to a lack of understanding of proper EVSE installation and maintenance. Considering that EVSEs have a high rate of failure, estimated at 30 to 50% (SAE), reliability is essential when building EV infrastructure and gaining user acceptance.

Webinar: Electrical Equipment Safety with Fluke


When safety is on top of mind, everyone benefits. Ensuring that your facility employs the best workplace practices, test tool standards, and ratings, and considers the dangers and causes of incidents will make for a safer work environment. Taking steps to improve these aspects will allow you to enjoy benefits, such as increased productivity and reduced assets-related and accident-related costs. Many tools can help you improve safety by testing, maintaining, monitoring, or troubleshooting live electrical equipment.

Click on a category to view a selection of compatible accessories with the Fluke PRV240 Proving Unit, 240V.

Fluke TB25 Tool Bucket Organizer Bag, 5.2 gal TB25
Durable and rugged, this tool bucket organizer bag has a 5.2-gallon capacity that can be relied on to protect and safely carry a variety of test tools and accessories. With its waterproof hard bottom shell, this versatile organizer has a total of 28 pockets that can fit hand tools, DMMs, clamp meters, test probes, and more.




Ask a question about Fluke PRV240 Proving Unit, 240V

Customer Reviews for the Fluke PRV240

More Fluke Products

Between March 11 and June 30, 2024 spend $500 or more and get a free Fluke tool or bundle with your purchase.
Calibration Lab