Quick, safe, and easy to use, this electrical tester measures voltage up to 600 V AC without test leads and troubleshoots with all power supply measurements at-a-glance. In addition, this tester features FieldSense technology, allowing it to detect AC voltage, current, and frequency measurements without making electrical contact to live wires.
Quick, safe, and easy to use, this electrical tester measures voltage up to 600 V AC without test leads and troubleshoots with all power supply measurements at-a-glance. In addition, this tester features FieldSense technology, allowing it to detect AC voltage, current, and frequency measurements without making electrical contact to live wires.
Working in cramped electrical boxes and finding safe metallic contact points is often challenging, which is why this electrical tester is ideal for situations like this. Measure voltage without test leads with FieldSense technology, which lets you quickly and safely take measurements by sliding the open fork over a conductor.
Features
Applications
Measurement Specifications | |
FieldSense AC Voltage | Requires test leads: No Range: 600 V Resolution: 1 V Accuracy: ±(3% + 3 counts), 45 to 66 Hz |
FieldSense AC Current | Requires test leads: No Range: 200 A Resolution: 0.1 A Accuracy: ±(3% + 3 counts), 45 to 66 Hz |
V AC | Requires test leads: Yes Range: 600 V Resolution: 1 V Accuracy: ±(1.5% + 2 counts), 45 to 66 Hz |
V DC | Requires test leads: Yes Range: 600 V Resolution: 1 V Accuracy: ±(1% + 2 counts) |
Resistance | Requires test leads: Yes Range: 2000 Ω Resolution: 1 Ω Accuracy: ±(1% + 2 counts) |
Safety (measurement category) | 600 V CAT III |
General Specifications | |
Calibration | One-year calibration cycle |
Temperature | Operating: 14 to 122°F (-10 to 50°C) Storage: -22 to 140°F (-30 to 60°C) |
Relative Humidity | 0 to 90%, 41 to 86°F (5 to 30°C) 0 to 75%, 86 to 104°F (30 to 40°C) 0 to 45%, 104 to 122°F (40 to 50°C) |
Altitude | Operating: 6562' (2000 m) Storage: 32,808' (10,000 m) |
Temperature Coefficient | 0.1 x (specified accuracy)/°C for <18°C or >28°C (<64.4°F or >82.4°F) |
Safety | IEC/EN 61010-1, IEC/EN 61010-2-033: Pollution Degree 2 |
Electromagnetic Environment | IEC/EN 61326-1: Portable |
Battery Type and Life | 2 x AA (IEC LR6) 360 hours continuous, typical 200 hours using FieldSense |
Fork Opening | 0.7" (17.8 mm) |
Dimensions | 2.4 x 10.2 x 1.7" (61.1 x 259.3 x 43.8 mm) |
Weight | 0.78 lbs (0.35 kg) |
Click on a category to view a selection of compatible accessories with the Fluke T6-600 Electrical Tester, 600 V, 200 A.
Measurement Specifications | |
FieldSense AC Voltage | Requires test leads: No Range: 600 V Resolution: 1 V Accuracy: ±(3% + 3 counts), 45 to 66 Hz |
FieldSense AC Current | Requires test leads: No Range: 200 A Resolution: 0.1 A Accuracy: ±(3% + 3 counts), 45 to 66 Hz |
V AC | Requires test leads: Yes Range: 600 V Resolution: 1 V Accuracy: ±(1.5% + 2 counts), 45 to 66 Hz |
V DC | Requires test leads: Yes Range: 600 V Resolution: 1 V Accuracy: ±(1% + 2 counts) |
Resistance | Requires test leads: Yes Range: 2000 Ω Resolution: 1 Ω Accuracy: ±(1% + 2 counts) |
Safety (measurement category) | 600 V CAT III |
General Specifications | |
Calibration | One-year calibration cycle |
Temperature | Operating: 14 to 122°F (-10 to 50°C) Storage: -22 to 140°F (-30 to 60°C) |
Relative Humidity | 0 to 90%, 41 to 86°F (5 to 30°C) 0 to 75%, 86 to 104°F (30 to 40°C) 0 to 45%, 104 to 122°F (40 to 50°C) |
Altitude | Operating: 6562' (2000 m) Storage: 32,808' (10,000 m) |
Temperature Coefficient | 0.1 x (specified accuracy)/°C for <18°C or >28°C (<64.4°F or >82.4°F) |
Safety | IEC/EN 61010-1, IEC/EN 61010-2-033: Pollution Degree 2 |
Electromagnetic Environment | IEC/EN 61326-1: Portable |
Battery Type and Life | 2 x AA (IEC LR6) 360 hours continuous, typical 200 hours using FieldSense |
Fork Opening | 0.7" (17.8 mm) |
Dimensions | 2.4 x 10.2 x 1.7" (61.1 x 259.3 x 43.8 mm) |
Weight | 0.78 lbs (0.35 kg) |
Click on a category to view a selection of compatible accessories with the Fluke T6-600 Electrical Tester, 600 V, 200 A.