Built for accuracy and portability, this sensor allows for safe connections to DC bus bars up to 1.5 kV as well as instrument voltage inputs. With a measurement range of 1500 V and an accuracy of 0.1%, the voltage can be scaled in the instrument to provide results in real units.
Built for accuracy and portability, this sensor allows for safe connections to DC bus bars up to 1.5 kV as well as instrument voltage inputs. With a measurement range of 1500 V and an accuracy of 0.1%, the voltage can be scaled in the instrument to provide results in real units.
Features
Electrical | |
Measurement Range | 1000 V AC rms, 1500 V DC |
Maximum Voltage | 1000 V AC rms, continuous, 1500 V DC (single-range) |
Accuracy | 0.1% of reading + 0.1% of range |
Bandwidth | 100 kHz (maximum) |
Input Impedance | 10 MΩ/<10 pF |
Scale | 4 mV/V |
Common Mode Rejection Ratio | 60 dB at 50 Hz |
Temperature Coefficients | 0.05%/°C (<18°C or >28°C) |
Over-range Protection | 10% over range |
General Specifications | |
Temperature | Operating: 14 to 122°F (-10 to 50°C) Storage: -22 to 140°F (-30 to 60°C) |
Operating Humidity | Non-condensing (<50°F [10°C]) ≤90% RH (at 50 to 86°F [10 to 30°C]) ≤75% RH (at 86 to 104°F [30 to 40°C]) ≤45% RH (at 104 to 122°F [40 to 50°C]) |
Altitude | Operating: 6561.68' (2000 m) Storage: 39,370.1' (12,000 m) |
Safety | General: IEC 61010-1: Pollution Degree 2 Measurement: IEC 61010-2-030: CAT III 1000 V, CAT IV 600 V, DC 1500 V |
Terminal | Input: 4 mm banana jacks Output: BNC (female) |
Battery | Type: 4 x AA, IEC LR6 Life: 168 hours (typically) |
Indicator | Low battery flashes red Working flashes green |
Ingress Protection | IEC 60529: IP40 (terminals mated) |
Dimensions | 5.43 x 2.95 x 1.77" (138 x 75 x 45 mm) |
Weight | 0.65 lbs (295 g), including battery |
Click on a category to view a selection of compatible accessories with the Fluke U1500S High Voltage Differential Probe, 1500 V.
Electrical | |
Measurement Range | 1000 V AC rms, 1500 V DC |
Maximum Voltage | 1000 V AC rms, continuous, 1500 V DC (single-range) |
Accuracy | 0.1% of reading + 0.1% of range |
Bandwidth | 100 kHz (maximum) |
Input Impedance | 10 MΩ/<10 pF |
Scale | 4 mV/V |
Common Mode Rejection Ratio | 60 dB at 50 Hz |
Temperature Coefficients | 0.05%/°C (<18°C or >28°C) |
Over-range Protection | 10% over range |
General Specifications | |
Temperature | Operating: 14 to 122°F (-10 to 50°C) Storage: -22 to 140°F (-30 to 60°C) |
Operating Humidity | Non-condensing (<50°F [10°C]) ≤90% RH (at 50 to 86°F [10 to 30°C]) ≤75% RH (at 86 to 104°F [30 to 40°C]) ≤45% RH (at 104 to 122°F [40 to 50°C]) |
Altitude | Operating: 6561.68' (2000 m) Storage: 39,370.1' (12,000 m) |
Safety | General: IEC 61010-1: Pollution Degree 2 Measurement: IEC 61010-2-030: CAT III 1000 V, CAT IV 600 V, DC 1500 V |
Terminal | Input: 4 mm banana jacks Output: BNC (female) |
Battery | Type: 4 x AA, IEC LR6 Life: 168 hours (typically) |
Indicator | Low battery flashes red Working flashes green |
Ingress Protection | IEC 60529: IP40 (terminals mated) |
Dimensions | 5.43 x 2.95 x 1.77" (138 x 75 x 45 mm) |
Weight | 0.65 lbs (295 g), including battery |
Click on a category to view a selection of compatible accessories with the Fluke U1500S High Voltage Differential Probe, 1500 V.