Confidently take reliable readings with this clamp meter, and is for use with high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, and rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Confidently take reliable readings with this clamp meter, and is for use with high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, and rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Features
Current Measurement DC and AC 10 to 100 Hz | |
Range | 40 A/400 A/2000 A/1400 AC RMS |
Resolution | 10 mA/100 mA/1 A |
Accuracy | A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits |
Trigger Level for Inrush | 0.50 A/5.0 A/5 A |
Trigger Level for Hz Filter OFF | 2.50 A/2.5 A/8 A |
Trigger Level for Hz Filter ON | 0.50 A/2.5 A/8 A |
Crest Factor (50/60 Hz) | |
Range | 40 A/400 A/2000 A/1400 AC RMS |
Crest Factor | 2 at 33 A, 2.4 at 27 A 2 at 330 A, 2.4 at 270 A 2 at 1000 A, 2.4 at 833 A |
Current Measurement AC 100.1 Hz to 1 kHz | |
Range | 40 A/400 A/2000 A; 1400 AC RMS |
Resolution | 10 mA/100 mA/1 A |
Accuracy | 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits |
Trigger Level for Inrush | 0.50 A/5.0 A/5 A |
Trigger Level for Hz Filter OFF | 2.50 A/2.5 A/8 A |
Trigger Level for Hz Filter ON | 0.50 A/2.5 A/8 A |
Frequency Measurement | |
Measurement Range | 5.0 Hz to 1 kHz |
Resolution | 0.1 Hz (15 Hz to 399.9 Hz) 1 Hz (400 Hz to 1 kHz) |
Accuracy | 5.0 to 100 Hz: 0.2% + 2 counts 100.1 Hz to 1 kHz: 0.5% + 5 counts |
Environmental Specifications | |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Operating Humidity | 0 to 95% (non-condensing) |
Operating Altitude | 6561.68' (2000 m) |
Storage Altitude | 32,808.4' (10,000 m) |
IP Rating | 42 (indoor use only) |
Drop Test Requirements | 3.28' (1 m) |
EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 |
Temperature Coefficients | Current: 0.1% of reading per °C outside 22°C to 24°C Voltage: 0.1% of reading per °C outside 22°C to 24°C |
General Specifications | |
Battery | Type: 6 x 1.5 V AA NEDA 15 A or IEC LR6 Life: 100 hours |
Test Leads | Rated to 1000 V |
Jaw Size | 2.28" (58 mm) |
Dimensions | 12 x 3.75 x 2" (300 x 98 x 52 mm) |
Weight | 1.8 lbs (0.814 kg) |
Safety Rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III |
Click on a category to view a selection of compatible accessories with the Fluke 353 True RMS Clamp Meter, 2000 A.
Current Measurement DC and AC 10 to 100 Hz | |
Range | 40 A/400 A/2000 A/1400 AC RMS |
Resolution | 10 mA/100 mA/1 A |
Accuracy | A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits |
Trigger Level for Inrush | 0.50 A/5.0 A/5 A |
Trigger Level for Hz Filter OFF | 2.50 A/2.5 A/8 A |
Trigger Level for Hz Filter ON | 0.50 A/2.5 A/8 A |
Crest Factor (50/60 Hz) | |
Range | 40 A/400 A/2000 A/1400 AC RMS |
Crest Factor | 2 at 33 A, 2.4 at 27 A 2 at 330 A, 2.4 at 270 A 2 at 1000 A, 2.4 at 833 A |
Current Measurement AC 100.1 Hz to 1 kHz | |
Range | 40 A/400 A/2000 A; 1400 AC RMS |
Resolution | 10 mA/100 mA/1 A |
Accuracy | 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits |
Trigger Level for Inrush | 0.50 A/5.0 A/5 A |
Trigger Level for Hz Filter OFF | 2.50 A/2.5 A/8 A |
Trigger Level for Hz Filter ON | 0.50 A/2.5 A/8 A |
Frequency Measurement | |
Measurement Range | 5.0 Hz to 1 kHz |
Resolution | 0.1 Hz (15 Hz to 399.9 Hz) 1 Hz (400 Hz to 1 kHz) |
Accuracy | 5.0 to 100 Hz: 0.2% + 2 counts 100.1 Hz to 1 kHz: 0.5% + 5 counts |
Environmental Specifications | |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Operating Humidity | 0 to 95% (non-condensing) |
Operating Altitude | 6561.68' (2000 m) |
Storage Altitude | 32,808.4' (10,000 m) |
IP Rating | 42 (indoor use only) |
Drop Test Requirements | 3.28' (1 m) |
EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 |
Temperature Coefficients | Current: 0.1% of reading per °C outside 22°C to 24°C Voltage: 0.1% of reading per °C outside 22°C to 24°C |
General Specifications | |
Battery | Type: 6 x 1.5 V AA NEDA 15 A or IEC LR6 Life: 100 hours |
Test Leads | Rated to 1000 V |
Jaw Size | 2.28" (58 mm) |
Dimensions | 12 x 3.75 x 2" (300 x 98 x 52 mm) |
Weight | 1.8 lbs (0.814 kg) |
Safety Rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III |
Click on a category to view a selection of compatible accessories with the Fluke 353 True RMS Clamp Meter, 2000 A.