A solar installation efficiency tester and I-V curve tracer in one unit measures single-phase photovoltaic system up to 1500 V / 10 A to 1000 V/ 15 A. It is compatible with the HTANALYSIS for wireless transfer of measurement data via WiFi.
A solar installation efficiency tester and I-V curve tracer in one unit measures single-phase photovoltaic system up to 1500 V / 10 A to 1000 V/ 15 A. It is compatible with the HTANALYSIS for wireless transfer of measurement data via WiFi.
The solar installation efficiency tester and I-V curve tracer is ideal for maintenance and efficiency tests on single-phase installations. It is a multifunction device that performs an automatic test according to the reference standards. The current and voltage at modules/strings output are measured with the 4-terminal method, which allows extending possible measuring cables without considering any compensation of their resistance. Because of this, the device can clearly determine if the reading of I-V curve complies with the specifications declared by the panel manufacturer.
Features
DC Voltage | Range (V): 15.0 / 99.9 Resolution (V): 0.1 Accuracy: ±(0.5%rdg+2dgt) Range (V): 100.0 / 1499.9 Resolution (V): 0.3 Accuracy: ±(0.5%rdg+2dgt) |
AC TRMS Voltage Range (V): 50.0 / 265.0 Resolution (V): 0.1 Accuracy: ±(0.5%rdg+2dgt) | |
DC Current (by external transducer clamp) | Range (mV): -1100 / -5 Resolution (mV): 0.1 Accuracy: ±(1.0%rdg + 0.6mV) Range (mV): 5 / 1100 Resolution (mV): 0.1 Accuracy: ±(1.0%rdg + 0.6mV) |
AC TRMS Current (by external transducer clamp) | Range (mV): 1 / 1200 Resolution (mV): 0.1 Frequency: 47.5 / 63.0 Accuracy: ±(1.0%rdg + 0.6mV) |
Frequency | Range (Hz): 47.5 / 63.0Hz Resolution (Hz): 0.01 Accuracy: ±(0.2%rdg+1dgt) |
Irradiance (with reference cell) | Range (mV): 1.0 / 65.0 Resolution (mV): 0.1 Accuracy: ±(1.0%rdg+ 5dgt) |
Display | 128 x 128 custom LCD with backlight |
Memory | max 99 yield test ; 249 curves (I-V curve test), 999 IVCK |
DC Voltage | Range (V): 15.0 / 99.9 Resolution (V): 0.1 Accuracy: ±(0.5%rdg+2dgt) Range (V): 100.0 / 1499.9 Resolution (V): 0.3 Accuracy: ±(0.5%rdg+2dgt) |
AC TRMS Voltage Range (V): 50.0 / 265.0 Resolution (V): 0.1 Accuracy: ±(0.5%rdg+2dgt) | |
DC Current (by external transducer clamp) | Range (mV): -1100 / -5 Resolution (mV): 0.1 Accuracy: ±(1.0%rdg + 0.6mV) Range (mV): 5 / 1100 Resolution (mV): 0.1 Accuracy: ±(1.0%rdg + 0.6mV) |
AC TRMS Current (by external transducer clamp) | Range (mV): 1 / 1200 Resolution (mV): 0.1 Frequency: 47.5 / 63.0 Accuracy: ±(1.0%rdg + 0.6mV) |
Frequency | Range (Hz): 47.5 / 63.0Hz Resolution (Hz): 0.01 Accuracy: ±(0.2%rdg+1dgt) |
Irradiance (with reference cell) | Range (mV): 1.0 / 65.0 Resolution (mV): 0.1 Accuracy: ±(1.0%rdg+ 5dgt) |
Display | 128 x 128 custom LCD with backlight |
Memory | max 99 yield test ; 249 curves (I-V curve test), 999 IVCK |