TRMS or MEAN value detection mode can be selected. Features a large data internal memory: 1,600 data (logging), 100 data (manual).
TRMS or MEAN value detection mode can be selected. Features a large data internal memory: 1,600 data (logging), 100 data (manual).
Features
DC V | |
Range | 600.0mV/6.000V/60.00V/600.0V/1000V |
Accuracy | 600.0mV/6.000V/60.00V/600.0V: 0.09+2 1000V: 0.15+2 |
Input Impedance | 600.0mV/60.00V/600.0V/1000V: 10MΩ 6.000V: 11MΩ |
Overload Protection | 1000V DC 1000V rms AC |
AC V | |
Range | 600.0mV/6.000V/60.00V/600.0V/1000V |
Accuracy | 50/60Hz: 0.5+5 40 to 500Hz: 1+5 500Hz to 1kHz: 1.5+5 (except for 1000V) |
Input Impedance | 600.0mV: 10MΩ<200pF 6.000V: 11MΩ<50pF 60.00V/600.0V/1000V: 10MΩ<50pF |
Overload Protection | 1000V rms AC 1000V DC |
DC A | |
Range | 600.0µA/6000µA/60.00mA/440.0mA/6.000A/10.00A |
Accuracy | 600.0µA/6000µA/60.00mA: 0.2+2 440.0mA/6.000A/10.00A: 0.5+5 |
Voltage Drop | 600.0µA/6000µA: <0.12mV/µA 60.00mA/440.0mA: <3.3mV/mA 6.000A/10.00A: <0.1V/A |
Overload Protection | 600.0µA/6000µA/60.00mA/440.0mA: 440mA Protected by a 40mA/1000V fuse 6.000A/10.00A: 10A Protected by A 10.00A 10A/1000V fuse |
AC A | |
Range | 600.0µA/6000µA/60.00mA/440.0mA/6.000A/10.00A |
Accuracy | 50/60Hz: 0.75+5 40Hz to 1kHz: 1.5+5 |
Voltage Drop | 600.0µA/6000µA: <0.12mV/µA 60.00mA/440.0mA: <3.3mV/mA 6.000A/10.00A: <0.1V/A |
Overload Protection | 600.0µA/6000µA/60.00mA/440.0mA: 440mA Protected by a 40mA/1000V fuse 6.000A/10.00A: 10A Protected by A 10.00A 10A/1000V fuse |
DC V | |
Range | 600.0mV/6.000V/60.00V/600.0V/1000V |
Accuracy | 600.0mV/6.000V/60.00V/600.0V: 0.09+2 1000V: 0.15+2 |
Input Impedance | 600.0mV/60.00V/600.0V/1000V: 10MΩ 6.000V: 11MΩ |
Overload Protection | 1000V DC 1000V rms AC |
AC V | |
Range | 600.0mV/6.000V/60.00V/600.0V/1000V |
Accuracy | 50/60Hz: 0.5+5 40 to 500Hz: 1+5 500Hz to 1kHz: 1.5+5 (except for 1000V) |
Input Impedance | 600.0mV: 10MΩ<200pF 6.000V: 11MΩ<50pF 60.00V/600.0V/1000V: 10MΩ<50pF |
Overload Protection | 1000V rms AC 1000V DC |
DC A | |
Range | 600.0µA/6000µA/60.00mA/440.0mA/6.000A/10.00A |
Accuracy | 600.0µA/6000µA/60.00mA: 0.2+2 440.0mA/6.000A/10.00A: 0.5+5 |
Voltage Drop | 600.0µA/6000µA: <0.12mV/µA 60.00mA/440.0mA: <3.3mV/mA 6.000A/10.00A: <0.1V/A |
Overload Protection | 600.0µA/6000µA/60.00mA/440.0mA: 440mA Protected by a 40mA/1000V fuse 6.000A/10.00A: 10A Protected by A 10.00A 10A/1000V fuse |
AC A | |
Range | 600.0µA/6000µA/60.00mA/440.0mA/6.000A/10.00A |
Accuracy | 50/60Hz: 0.75+5 40Hz to 1kHz: 1.5+5 |
Voltage Drop | 600.0µA/6000µA: <0.12mV/µA 60.00mA/440.0mA: <3.3mV/mA 6.000A/10.00A: <0.1V/A |
Overload Protection | 600.0µA/6000µA/60.00mA/440.0mA: 440mA Protected by a 40mA/1000V fuse 6.000A/10.00A: 10A Protected by A 10.00A 10A/1000V fuse |