Lascar EL-21CFR-ULT+ High-Accuracy Ultra Low Temperature Cryogenic Vaccine Data Logger, -148 to 212°F

Model: EL-21CFR-ULT+

Lascar EL-21CFR-ULT+ High-Accuracy Ultra Low Temperature Cryogenic Vaccine Data Logger, -148 to 212°F

Model: EL-21CFR-ULT+

Compliant with 21CFR Part 11, this high-accuracy ultra-low temperature cryogenic vaccine data logger is capable of monitoring vaccines in cryogenic dry ice storage and features a -148 to 212°F (-100 to 100°C) range with a probe. Additionally, this data logger records over 32,000 readings and is simple to set up using the 21CFR Part 11 software.

Compliant with 21CFR Part 11, this high-accuracy ultra-low temperature cryogenic vaccine data logger is capable of monitoring vaccines in cryogenic dry ice storage and features a -148 to 212°F (-100 to 100°C) range with a probe. Additionally, this data logger records over 32,000 readings and is simple to set up using the 21CFR Part 11 software.

Your Price $149.49 USD
Availability 2 to 3 Weeks
Quantity

Lascar EL-21CFR-ULT+ Offers

Comes with a software that allows users to set high and low alarm thresholds with alarm hold and delayed start features as well.

Features

  • T-type probe on 3.28' (1 m) cable
  • Stores over 32,000 readings
  • Logging rates between 1 second and 12 hours
  • Immediate and delayed logging start
  • User-programmable alarm thresholds
  • Status indication via red and green LEDs
  • Use as part of a 21CFR Part 11 compliant system
  • EasyLog 21CFR software available as a free download

Applications

  • Ultra-low temperature vaccine storage
  • Vaccine storage
  • Pharmaceutical cold chain

Lascar EL-21CFR-ULT+ Specifications

Measurement Range -148 to 212°F (-100 to 100°C)
Accuracy ±3.2°F (±1.8°C) typical
Readings 32,510
Logging Rate User selectable between 1 second and 12 hours
Operating Temperature (Logger Only) 14 to 104°F (-10 to 40°C)
Battery Life 2 years
Dimensions Logger: 4.6 x 1.1 x 1.1" (118 x 27 x 27 mm)
Probe: 11.8 x θ0.06 x 39.4" cable (300 x θ1.5 mm x 1 m)
Click here for complete specifications on the Lascar EL-21CFR-ULT+

What's included with the Lascar EL-21CFR-ULT+

  • High-Accuracy Ultra Low Temperature Cryogenic Vaccine Data Logger
  • Thermocouple Probe
  • Mounting Bracket
  • Battery

Click on a category to view a selection of compatible accessories with the Lascar EL-21CFR-ULT+ High-Accuracy Ultra Low Temperature Cryogenic Vaccine Data Logger, -148 to 212°F.

Lascar EL-P-TC-GLY Thermocouple Probe with 6.56' cable EL-P-TC-GLY
Capable of providing a buffered response to changes in the temperature, thisthermocouple probe helps to simulate the thermal lag experienced by products stored in the monitored environment. In addition, it is ideal for use loggers with a standard type-K thermocouple input.




Lascar EL-P-TC-K-SPIKE K-Type Thermocouple Probe, 0.13" EL-P-TC-K-SPIKE
Ideal for use with temperature data loggers, this K-type thermocouple probe features a 0.13" (3.3 mm) diameter and is made from 316 stainless steel. In addition, this probe also features a Class 1 tolerance and is sealed to IP66 standard on a 3.28' (1 m) cable.




Lascar EL-P-TPX+ Calibratable Thermistor Probe for the EL-WiFi-TPX+ Data Loggers, 9.8' EL-P-TPX+
Intended for use with the EL-WiFi-TPX+ data loggers, this high accuracy and calibratable probe is 9.84' (3 m) long with a stainless steel tip.




Lascar FRIDGE INSTALL-TP Temperature Probe FRIDGE INSTALL-TP
For use with temperature data loggers, the temperature probe is ideal in measuring temperature.




Lascar THERMOCOUPLE-CS Thermocouple Probe THERMOCOUPLE-CS
Used as an accessory for temperature measurement.




Ask a question about Lascar EL-21CFR-ULT+ High-Accuracy Ultra Low Temperature Cryogenic Vaccine Data Logger, -148 to 212°F

Customer Reviews for the Lascar EL-21CFR-ULT+

Lascar EL-21CFR-ULT+ Offers

Comes with a software that allows users to set high and low alarm thresholds with alarm hold and delayed start features as well.

Features

  • T-type probe on 3.28' (1 m) cable
  • Stores over 32,000 readings
  • Logging rates between 1 second and 12 hours
  • Immediate and delayed logging start
  • User-programmable alarm thresholds
  • Status indication via red and green LEDs
  • Use as part of a 21CFR Part 11 compliant system
  • EasyLog 21CFR software available as a free download

Applications

  • Ultra-low temperature vaccine storage
  • Vaccine storage
  • Pharmaceutical cold chain

Lascar EL-21CFR-ULT+ Specifications

Measurement Range -148 to 212°F (-100 to 100°C)
Accuracy ±3.2°F (±1.8°C) typical
Readings 32,510
Logging Rate User selectable between 1 second and 12 hours
Operating Temperature (Logger Only) 14 to 104°F (-10 to 40°C)
Battery Life 2 years
Dimensions Logger: 4.6 x 1.1 x 1.1" (118 x 27 x 27 mm)
Probe: 11.8 x θ0.06 x 39.4" cable (300 x θ1.5 mm x 1 m)
Click here for complete specifications on the Lascar EL-21CFR-ULT+

What's included with the Lascar EL-21CFR-ULT+

  • High-Accuracy Ultra Low Temperature Cryogenic Vaccine Data Logger
  • Thermocouple Probe
  • Mounting Bracket
  • Battery

Click on a category to view a selection of compatible accessories with the Lascar EL-21CFR-ULT+ High-Accuracy Ultra Low Temperature Cryogenic Vaccine Data Logger, -148 to 212°F.

Lascar EL-P-TC-GLY Thermocouple Probe with 6.56' cable EL-P-TC-GLY
Capable of providing a buffered response to changes in the temperature, thisthermocouple probe helps to simulate the thermal lag experienced by products stored in the monitored environment. In addition, it is ideal for use loggers with a standard type-K thermocouple input.




Lascar EL-P-TC-K-SPIKE K-Type Thermocouple Probe, 0.13" EL-P-TC-K-SPIKE
Ideal for use with temperature data loggers, this K-type thermocouple probe features a 0.13" (3.3 mm) diameter and is made from 316 stainless steel. In addition, this probe also features a Class 1 tolerance and is sealed to IP66 standard on a 3.28' (1 m) cable.




Lascar EL-P-TPX+ Calibratable Thermistor Probe for the EL-WiFi-TPX+ Data Loggers, 9.8' EL-P-TPX+
Intended for use with the EL-WiFi-TPX+ data loggers, this high accuracy and calibratable probe is 9.84' (3 m) long with a stainless steel tip.




Lascar FRIDGE INSTALL-TP Temperature Probe FRIDGE INSTALL-TP
For use with temperature data loggers, the temperature probe is ideal in measuring temperature.




Lascar THERMOCOUPLE-CS Thermocouple Probe THERMOCOUPLE-CS
Used as an accessory for temperature measurement.




Ask a question about Lascar EL-21CFR-ULT+ High-Accuracy Ultra Low Temperature Cryogenic Vaccine Data Logger, -148 to 212°F

Customer Reviews for the Lascar EL-21CFR-ULT+

More Lascar Products

Calibration Lab