MadgeTech OctProcess Current Data Logger

MadgeTech OctProcess Current Data Logger

Model Selection

MadgeTech OctProcess-100mA Datalogger
OctProcessV2-100mA $1,049.00 USD Availability:
2 to 3 Weeks
MadgeTech OctProcess-1mA Datalogger
OctProcessV2-1mA $1,049.00 USD Availability:
2 to 3 Weeks
MadgeTech OctProcess-25mA Datalogger
OctProcessV2-25mA $1,049.00 USD Availability:
2 to 3 Weeks

Model Selection

8 Channel, Battery Powered, Low Level DC Current Data Logger. Features user-programmable Engineering Units and offset/gain calculation so input signals can be scaled to proper units being measured.

Please note: The Madgetech IFC200 USB Interface Cable Package is a required accessory for use with this product.

8 Channel, Battery Powered, Low Level DC Current Data Logger. Features user-programmable Engineering Units and offset/gain calculation so input signals can be scaled to proper units being measured.

Please note: The Madgetech IFC200 USB Interface Cable Package is a required accessory for use with this product.

MadgeTech OctProcess-100mA Datalogger
OctProcessV2-100mA $1,049.00 USD Availability:
2 to 3 Weeks
MadgeTech OctProcess-1mA Datalogger
OctProcessV2-1mA $1,049.00 USD Availability:
2 to 3 Weeks
MadgeTech OctProcess-25mA Datalogger
OctProcessV2-25mA $1,049.00 USD Availability:
2 to 3 Weeks

MadgeTech OctProcessV2 Offers

The OctProcess is an eight channel, battery powered, stand alone low level DC current data logger. The device records time and date stamped DC current data from external sensors, transducers and many other sources.

Features

  • 16-bit readings provide high resolution
  • User-defined engineering units
  • Programmable start time and recording interval
  • Low cost
  • Real-time operation
  • Reusable
  • Compact
  • User-friendly

Applications

  • 4 to 20 mA recording
  • pH recording
  • Low level signal monitoring
  • Photovoltaic studies
  • Battery studies
  • Biological sensor monitoring
  • Factory process control
  • Research and development
  • Medical and Pharmaceutical
  • Environmental studies

The data logger features user-programmable Engineering Units and offset/gain calculations so input signals can be scaled to proper units being measured. For example, a water meter with a 4-20 mA output can be displayed as litres or gallons, etc., in the software graph and data. Negative current signals can be monitored and recorded, for a broad range of applications.

Three different DC current ranges are available ±1 mA, ±25 mA or ±100 mA. This is an all-in-one compact, portable, easy to use device that will measure and record data for up to 16,383 readings per channel. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. The device can be started and stopped directly from your computer and its small size allows it to fit almost anywhere. The OctProcess makes data retrieval quick and easy. Simply plug it into an empty COM or USB port and our user-friendly software does the rest.

MadgeTech OctProcessV2 Specifications

Current Range ±1 mA, ±25 mA , ±100 mA
Current Resolution ±1 mA: 0.05 µA
±25 mA: 1 µA
±100 mA: 5 µA
Current Calibrate Accuracy ±1 mA: ±0.5 %FSR at 25 °C
±25 mA and ±100 mA: ±0.1 %FSR at 25 °C
Current Input Impedance ±1: 50 Ω
±25 mA: 10 Ω
±100: 2 Ω
Memory 16,383 readings per channel
Reading Rate 1 reading every second up to 1 reading every 12 hours
Baud Rate 2,400
Channels 8
LED Indicators None
Battery Life 1 year
Material Anodized aluminum
Dimensions 3.5 x 4.4 x 1.5 in (89 x 112 x 39 mm)
Operating Environment -4 to 140°F (-20 to 60 °C), 0 %RH to 95 %RH non-condensing
Click here for complete specifications on the MadgeTech OctProcessV2

What's included with the MadgeTech OctProcessV2

  • MadgeTech OctProcess Current Data Logger

Click on a category to view a selection of compatible accessories with the MadgeTech OctProcess Current Data Logger.

MadgeTech U9VL-J Lithium Battery, 9.0V U9VL-J
9.0 Volt, Lithium Battery, 1200 mAH.




MadgeTech CON-3POSPLG-00 3-Position Terminal Block Terminal Blocks-3 Position
For use with MadgeTech data loggers. Allows for connection between the logger and a variety of sensors for measurement input.




MadgeTech IFC200 USB Interface Cable Package IFC200
“Plug and play” interface communicates between stand alone data loggers and MadgeTech software. Through this interface, loggers can be started, stopped or downloaded.




Ask a question about MadgeTech OctProcess Current Data Logger

Customer Reviews for the MadgeTech OctProcessV2

MadgeTech OctProcessV2 Offers

The OctProcess is an eight channel, battery powered, stand alone low level DC current data logger. The device records time and date stamped DC current data from external sensors, transducers and many other sources.

Features

  • 16-bit readings provide high resolution
  • User-defined engineering units
  • Programmable start time and recording interval
  • Low cost
  • Real-time operation
  • Reusable
  • Compact
  • User-friendly

Applications

  • 4 to 20 mA recording
  • pH recording
  • Low level signal monitoring
  • Photovoltaic studies
  • Battery studies
  • Biological sensor monitoring
  • Factory process control
  • Research and development
  • Medical and Pharmaceutical
  • Environmental studies

The data logger features user-programmable Engineering Units and offset/gain calculations so input signals can be scaled to proper units being measured. For example, a water meter with a 4-20 mA output can be displayed as litres or gallons, etc., in the software graph and data. Negative current signals can be monitored and recorded, for a broad range of applications.

Three different DC current ranges are available ±1 mA, ±25 mA or ±100 mA. This is an all-in-one compact, portable, easy to use device that will measure and record data for up to 16,383 readings per channel. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. The device can be started and stopped directly from your computer and its small size allows it to fit almost anywhere. The OctProcess makes data retrieval quick and easy. Simply plug it into an empty COM or USB port and our user-friendly software does the rest.

MadgeTech OctProcessV2 Specifications

Current Range ±1 mA, ±25 mA , ±100 mA
Current Resolution ±1 mA: 0.05 µA
±25 mA: 1 µA
±100 mA: 5 µA
Current Calibrate Accuracy ±1 mA: ±0.5 %FSR at 25 °C
±25 mA and ±100 mA: ±0.1 %FSR at 25 °C
Current Input Impedance ±1: 50 Ω
±25 mA: 10 Ω
±100: 2 Ω
Memory 16,383 readings per channel
Reading Rate 1 reading every second up to 1 reading every 12 hours
Baud Rate 2,400
Channels 8
LED Indicators None
Battery Life 1 year
Material Anodized aluminum
Dimensions 3.5 x 4.4 x 1.5 in (89 x 112 x 39 mm)
Operating Environment -4 to 140°F (-20 to 60 °C), 0 %RH to 95 %RH non-condensing
Click here for complete specifications on the MadgeTech OctProcessV2

What's included with the MadgeTech OctProcessV2

  • MadgeTech OctProcess Current Data Logger

Click on a category to view a selection of compatible accessories with the MadgeTech OctProcess Current Data Logger.

MadgeTech U9VL-J Lithium Battery, 9.0V U9VL-J
9.0 Volt, Lithium Battery, 1200 mAH.




MadgeTech CON-3POSPLG-00 3-Position Terminal Block Terminal Blocks-3 Position
For use with MadgeTech data loggers. Allows for connection between the logger and a variety of sensors for measurement input.




MadgeTech IFC200 USB Interface Cable Package IFC200
“Plug and play” interface communicates between stand alone data loggers and MadgeTech software. Through this interface, loggers can be started, stopped or downloaded.




Ask a question about MadgeTech OctProcess Current Data Logger

Customer Reviews for the MadgeTech OctProcessV2

More MadgeTech Products

Calibration Lab