FREE SHIPPING ON ONLINE ORDERS OVER $99*

Megger MIT515 (1001-936) 5kV Megohmmeter

Model: MIT515 | Order No: 1001-936 | UPC: 5036175224182

Megger MIT515 (1001-936) 5kV Megohmmeter

Model: MIT515 | Order No: 1001-936 | UPC: 5036175224182

Analog/Digital Resistance Tester Megohmmeter with a Lithium-Ion battery and a Max reading of 10 TOhms. CAT IV 600V.

Analog/Digital Resistance Tester Megohmmeter with a Lithium-Ion battery and a Max reading of 10 TOhms. CAT IV 600V.

Regular Price $4765.00 USD
Availability 1 in Stock
Quantity

Traceable In-House Calibration Certificate for your add MIT515

Traceable In-House Calibration Certificate for your add MIT515

Megger MIT515 Offers

Features

  • Industry best guard terminal accuracy
  • Smaller size and lightweight allows easier transport and use without compromising performance
  • Compact and lightweight for easy transport and use
  • Auto IR, DAR and PI
  • Unique dual case design provides additional user protection
  • Lithium-ion battery - extended capacity, rapid charge
  • Advanced memory with time/date stamp
  • CATIV 600V safety rating on all terminals

Applications

  • Testing the Insulation of High or Low Voltage Electric Equipment
  • Generators
  • Motors
  • Transformers
  • Cables
  • Switchgear
  • High-Voltage Power Cables
  • High-Voltage Buses
  • Large Motor/Generator Windings
  • Line and Substation Transformers
  • Spot Tests
  • Stepvoltage Tests
  • Dielectric Discharge Tests
  • Ramp Tests
  • Dielectric Absorption Tests
  • Acceptance Testing at Installation to Check Conformance to Specifications
  • Routine Preventive/Predictive Maintenance Testing After Installation
  • QA Testing as Part of the Manufacturing Process
  • Diagnostic Testing to Isolate Faulty Components for Repair
  • Rotating Machinery
  • Insulation Resistance of Armature and Field Windings

Megger MIT515 Specifications

Analog Insulation Range 100 kΩ to 10 TΩ
Digital Insulation Range 10 kΩ to 10 TΩ
Test Voltages 250 V, 500 V, 1000 V, 2500 V, and 5000 V
User Defined Test Voltages 100 V to 1 kV in 10 V Steps
1 kV to 5 kV in 25 V Steps
Accuracy (23°C) ±5% to 1 TΩ, ±20% to 10 TΩ
Voltage Output Accuracy (0 to 30°C) 4 to 0% ±10 V of nominal test voltage at 1 GΩ load
Voltmeter Range 30 to 660 V ac or dc, 50/60 Hz
Accuracy: ±3% ±3 V
Frequency Range: 45 Hz to 65 Hz
Short Circuit Current 3 mA Nominal, Max. Power on All Loads Outperforming Many
5 mA Testers
Insulation Alarm 100 kΩ to 1 GΩ
Current Measurement Range: 0.01 nA to 6 mA
Accuracy: ±5% ±0.2 nA at All Voltages
Capacitance Range Above 500 V 10 nF to 25 µF (Dependent on Measurement Voltage)
Accuracy (23°C): ±10% ±5 nF
Capacitor Charge <3 s per µF at 3 mA to 5 kV
Capacitor Discharge <250 ms/µF to Discharge from 5000 V to 50 V
Timer Range Up to 99 Minutes, 15 Seconds Minimum Setting
Memory Capacity 5 1/2 Hours Continuous Logging Every 5 Seconds or 33 Logged PI Tests or 350 Logged IR Tests
Industry-Standard Tests IR, IR(t), DAR, PI
Interface USB Type B (Device)
Real Time Output USB, 1 Reading/Second (Voltage, Current and Resistance)
Interference Rejection 1 mA per 250 V up to a maximum of 3 mA
Guard Terminal 2% Error Guarding 500 kΩ Leakage with 100 mΩ Load
Voltage Input Range 85 to 265 V, 50/60 Hz, 60 VA
Battery Type Lithium-Ion, 11.1 V, 5.2 A Hour, Meets IEC 62133:2003
Battery Life Typical Capacity 6 Hours Continuous at 5 kV with a 100 MW Load
Battery Charge Time 2.5 Hours from Deep Discharge, 2 Hours Normal Discharge
30 Minutes Quick Charge: 1 Hour Operation at 5 kV, 100 MW
Safety Meets the Requirements of IEC61010-1 CAT IV 600 V
Default Voltmeter Warns Operator of Applied Voltage Above 50 V
EMC Meets the requirements of IEC61326-1
Ingress Protection IP65 (Lid Closed)
IP40 (Lid Open)
Temperature Range Operating: -4 to 122°F (-20 to 50°C)
Storage: -13 to 149°F (-25 to 65°C)
Humidity Range 90% RH @ 104°F (40°C)
Altitude 3000 m, CAT rating maintained >2000 m* (*test load connected)
Dimensions 12 x 11 x 7" (315 x 285 x 181 mm)
Weight 10 lb (4.5 kg)
Click here for complete specifications on the Megger MIT515

What's included with the Megger MIT515

  • Megohmmeter
  • User Guide CD-ROM
  • Power Lead
  • 3 x 3m Lead Set, Medium Insulated Clips (5 kV,10 kV)

Click on a category to view a selection of compatible accessories with the Megger MIT515 (1001-936) 5kV Megohmmeter.

Megger 1002-648 Lead set, 15m (49 ft) 1002-648
Large size insulated clips.




Megger 6311-080 50' Shielded Lead Set for BM15 & MJ15 6311-080
Shielded Lead Set for use with the Megger BM15 & MJ15.




Megger CB101 Calibrated Check Box for 5 kV Megger Insulation Testers CB101
Suitable for checking the accuracy of insulation testers, this calibrated check box can measure a wide range of values with four resistors connected to the unit to check resistance readings with test voltages up to 5 kV DC. Get a calibration certificate with each check box showing the actual value of each resistance checkpoint.




Ask a question about Megger MIT515 (1001-936) 5kV Megohmmeter

Customer Reviews for the Megger MIT515

Megger MIT515 Offers

Features

  • Industry best guard terminal accuracy
  • Smaller size and lightweight allows easier transport and use without compromising performance
  • Compact and lightweight for easy transport and use
  • Auto IR, DAR and PI
  • Unique dual case design provides additional user protection
  • Lithium-ion battery - extended capacity, rapid charge
  • Advanced memory with time/date stamp
  • CATIV 600V safety rating on all terminals

Applications

  • Testing the Insulation of High or Low Voltage Electric Equipment
  • Generators
  • Motors
  • Transformers
  • Cables
  • Switchgear
  • High-Voltage Power Cables
  • High-Voltage Buses
  • Large Motor/Generator Windings
  • Line and Substation Transformers
  • Spot Tests
  • Stepvoltage Tests
  • Dielectric Discharge Tests
  • Ramp Tests
  • Dielectric Absorption Tests
  • Acceptance Testing at Installation to Check Conformance to Specifications
  • Routine Preventive/Predictive Maintenance Testing After Installation
  • QA Testing as Part of the Manufacturing Process
  • Diagnostic Testing to Isolate Faulty Components for Repair
  • Rotating Machinery
  • Insulation Resistance of Armature and Field Windings

Megger MIT515 Specifications

Analog Insulation Range 100 kΩ to 10 TΩ
Digital Insulation Range 10 kΩ to 10 TΩ
Test Voltages 250 V, 500 V, 1000 V, 2500 V, and 5000 V
User Defined Test Voltages 100 V to 1 kV in 10 V Steps
1 kV to 5 kV in 25 V Steps
Accuracy (23°C) ±5% to 1 TΩ, ±20% to 10 TΩ
Voltage Output Accuracy (0 to 30°C) 4 to 0% ±10 V of nominal test voltage at 1 GΩ load
Voltmeter Range 30 to 660 V ac or dc, 50/60 Hz
Accuracy: ±3% ±3 V
Frequency Range: 45 Hz to 65 Hz
Short Circuit Current 3 mA Nominal, Max. Power on All Loads Outperforming Many
5 mA Testers
Insulation Alarm 100 kΩ to 1 GΩ
Current Measurement Range: 0.01 nA to 6 mA
Accuracy: ±5% ±0.2 nA at All Voltages
Capacitance Range Above 500 V 10 nF to 25 µF (Dependent on Measurement Voltage)
Accuracy (23°C): ±10% ±5 nF
Capacitor Charge <3 s per µF at 3 mA to 5 kV
Capacitor Discharge <250 ms/µF to Discharge from 5000 V to 50 V
Timer Range Up to 99 Minutes, 15 Seconds Minimum Setting
Memory Capacity 5 1/2 Hours Continuous Logging Every 5 Seconds or 33 Logged PI Tests or 350 Logged IR Tests
Industry-Standard Tests IR, IR(t), DAR, PI
Interface USB Type B (Device)
Real Time Output USB, 1 Reading/Second (Voltage, Current and Resistance)
Interference Rejection 1 mA per 250 V up to a maximum of 3 mA
Guard Terminal 2% Error Guarding 500 kΩ Leakage with 100 mΩ Load
Voltage Input Range 85 to 265 V, 50/60 Hz, 60 VA
Battery Type Lithium-Ion, 11.1 V, 5.2 A Hour, Meets IEC 62133:2003
Battery Life Typical Capacity 6 Hours Continuous at 5 kV with a 100 MW Load
Battery Charge Time 2.5 Hours from Deep Discharge, 2 Hours Normal Discharge
30 Minutes Quick Charge: 1 Hour Operation at 5 kV, 100 MW
Safety Meets the Requirements of IEC61010-1 CAT IV 600 V
Default Voltmeter Warns Operator of Applied Voltage Above 50 V
EMC Meets the requirements of IEC61326-1
Ingress Protection IP65 (Lid Closed)
IP40 (Lid Open)
Temperature Range Operating: -4 to 122°F (-20 to 50°C)
Storage: -13 to 149°F (-25 to 65°C)
Humidity Range 90% RH @ 104°F (40°C)
Altitude 3000 m, CAT rating maintained >2000 m* (*test load connected)
Dimensions 12 x 11 x 7" (315 x 285 x 181 mm)
Weight 10 lb (4.5 kg)
Click here for complete specifications on the Megger MIT515

What's included with the Megger MIT515

  • Megohmmeter
  • User Guide CD-ROM
  • Power Lead
  • 3 x 3m Lead Set, Medium Insulated Clips (5 kV,10 kV)

Click on a category to view a selection of compatible accessories with the Megger MIT515 (1001-936) 5kV Megohmmeter.

Megger 1002-648 Lead set, 15m (49 ft) 1002-648
Large size insulated clips.




Megger 6311-080 50' Shielded Lead Set for BM15 & MJ15 6311-080
Shielded Lead Set for use with the Megger BM15 & MJ15.




Megger CB101 Calibrated Check Box for 5 kV Megger Insulation Testers CB101
Suitable for checking the accuracy of insulation testers, this calibrated check box can measure a wide range of values with four resistors connected to the unit to check resistance readings with test voltages up to 5 kV DC. Get a calibration certificate with each check box showing the actual value of each resistance checkpoint.




Ask a question about Megger MIT515 (1001-936) 5kV Megohmmeter

Customer Reviews for the Megger MIT515

More Megger Products