OAKTON pH/CON 700 Benchtop Meter, pH Electrode, Conductivity/Temp Probe and Probe Stand

Model: pH/CON 700 | Order No: WD-35413-00

OAKTON pH/CON 700 Benchtop Meter, pH Electrode, Conductivity/Temp Probe and Probe Stand

Model: pH/CON 700 | Order No: WD-35413-00

Easily toggle between pH, mV, conductivity, TDS, and temperature measurements at the press of a button. New compact design is over 40% smaller than other benchtop meters.

Easily toggle between pH, mV, conductivity, TDS, and temperature measurements at the press of a button. New compact design is over 40% smaller than other benchtop meters.

Sale Price $957.18 USD
Regular Price $1204.00 USD
Availability 15+ Weeks
Quantity

OAKTON pH/CON 700 Offers

The large display is easy to read even at a distance. Dual-display allows you to read both a measured parameter and temperature at a glance. The meter features pH auto-buffer recognition for both USA and NIST buffer sets (1.68, 4.01, 7.00, 10.01 and 12.45 or 1.68, 4.01. 6.18. 9.86, and 12.45), automatic or manual temperature compensation, temperature selectable in either °F or °C, display HOLD, and water-resistant membrane keypad. Previous calibration points, electrode slope and offset, and conductivity/TDS cell constants are stored in memory for quick and easy retrieval. The convenient pull-out quick reference card keeps keypad functions at your fingertips.

Features

  • Space-saving design takes up less room on the bench than other meters
  • Large display lets you see your measurements from across the lab
  • Conductivity and TDS autoranging chooses the best resolution for each measurement
  • Economical bench meter for basic pH and conductivity laboratory use

Applications

  • Laboratory

OAKTON pH/CON 700 Specifications

Measures pH, mV, conductivity, total dissolved solids (TDS), and temperature (°C or°F)
pH
Range -1.99 to 16.00
Resolution 0.01
Accuracy ±0.002
Calibration Up to 5 points (USA: 1.68,4.01, 7.00, 10.01, 12.45 or NIST: 1.68,4.01, 6.86, 9.18, 12.45) with autobuffer recognition
mV
Range ±1999 mV
Resolution 0.1 mV (±199.9 mV)
1 mV (Beyond)
Accuracy ±0.2 mV (±199.9 mV)
±2 mV (Beyond)
Calibration Offset up to ±150 mV
Conductivity
Range 0.00 ìS/cm to 200.0 mS/cm
Resolution 0.01 ìS; 0.1 ìS ; 1 ìS ; 0.01 mS ; 0.1 mS
Accuracy ±1 % full scale
Calibration Automatic (4 points): Maximum 1 per range
Manual (5 points): Maximum 1 per range
TDS
Range 0.00 ppm to 100 ppt @ 0.5 TDS factor (to 200 ppt @ 1.0 TDS factor)
Resolution 0.01 ppm; 0.1 ppm ; 1 ppm ; 0.01 ppt ; 0.1 ppt
Accuracy ±1 % full scale
Calibration Up to 5 points
Temperature
Range 0.0 to 100.0°C (32.0 to 212.0°F)
Resolution 0.1°C (0.1°F)
Accuracy ±0.5°C (±0.9°F)
Calibration Off set in 0.1° increments
Off set range: ±5°C (9°F)
General Specifications
Memory Up to 100 data sets
Dimensions 6 1/8 x 6 7/8 x 2 3/4" (15.5 x 17.5 x 6.9 cm)
Click here for complete specifications on the OAKTON pH/CON 700

What's included with the OAKTON pH/CON 700

  • Benchtop Meter
  • pH Electrode
  • Conductivity/Temperature Probe
  • Electrode Stand

Click on a category to view a selection of compatible accessories with the OAKTON pH/CON 700 Benchtop Meter, pH Electrode, Conductivity/Temp Probe and Probe Stand.

OAKTON WD-35608-72 Conductivity Probe for 700 & 2700 Meters, K=0.1, Epoxy Body WD-35608-72
This probe can be used for low conductivity measurements that are near or below 20mS. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-76 Conductivity Probe for 700 & 2700 Meters, K=1.0, Epoxy Body WD-35608-76
Having a 1.0K cell constant is ideal for midrange conductivity measurements. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-74 Conductivity Probe for 700 & 2700 Meters, K=1.0, Ultem Body WD-35608-74
Having a 1.0K cell constant is ideal for midrange conductivity measurements. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-78 Conductivity Probe for 700 & 2700 Meters, K=10, Epoxy Body WD-35608-78
This probe can be used for high conductivity measurements that are near or above 20mS. For use with CON 700/2700 and PC 700/2700.




Ask a question about OAKTON pH/CON 700 Benchtop Meter, pH Electrode, Conductivity/Temp Probe and Probe Stand

Customer Reviews for the OAKTON pH/CON 700

OAKTON pH/CON 700 Offers

The large display is easy to read even at a distance. Dual-display allows you to read both a measured parameter and temperature at a glance. The meter features pH auto-buffer recognition for both USA and NIST buffer sets (1.68, 4.01, 7.00, 10.01 and 12.45 or 1.68, 4.01. 6.18. 9.86, and 12.45), automatic or manual temperature compensation, temperature selectable in either °F or °C, display HOLD, and water-resistant membrane keypad. Previous calibration points, electrode slope and offset, and conductivity/TDS cell constants are stored in memory for quick and easy retrieval. The convenient pull-out quick reference card keeps keypad functions at your fingertips.

Features

  • Space-saving design takes up less room on the bench than other meters
  • Large display lets you see your measurements from across the lab
  • Conductivity and TDS autoranging chooses the best resolution for each measurement
  • Economical bench meter for basic pH and conductivity laboratory use

Applications

  • Laboratory

OAKTON pH/CON 700 Specifications

Measures pH, mV, conductivity, total dissolved solids (TDS), and temperature (°C or°F)
pH
Range -1.99 to 16.00
Resolution 0.01
Accuracy ±0.002
Calibration Up to 5 points (USA: 1.68,4.01, 7.00, 10.01, 12.45 or NIST: 1.68,4.01, 6.86, 9.18, 12.45) with autobuffer recognition
mV
Range ±1999 mV
Resolution 0.1 mV (±199.9 mV)
1 mV (Beyond)
Accuracy ±0.2 mV (±199.9 mV)
±2 mV (Beyond)
Calibration Offset up to ±150 mV
Conductivity
Range 0.00 ìS/cm to 200.0 mS/cm
Resolution 0.01 ìS; 0.1 ìS ; 1 ìS ; 0.01 mS ; 0.1 mS
Accuracy ±1 % full scale
Calibration Automatic (4 points): Maximum 1 per range
Manual (5 points): Maximum 1 per range
TDS
Range 0.00 ppm to 100 ppt @ 0.5 TDS factor (to 200 ppt @ 1.0 TDS factor)
Resolution 0.01 ppm; 0.1 ppm ; 1 ppm ; 0.01 ppt ; 0.1 ppt
Accuracy ±1 % full scale
Calibration Up to 5 points
Temperature
Range 0.0 to 100.0°C (32.0 to 212.0°F)
Resolution 0.1°C (0.1°F)
Accuracy ±0.5°C (±0.9°F)
Calibration Off set in 0.1° increments
Off set range: ±5°C (9°F)
General Specifications
Memory Up to 100 data sets
Dimensions 6 1/8 x 6 7/8 x 2 3/4" (15.5 x 17.5 x 6.9 cm)
Click here for complete specifications on the OAKTON pH/CON 700

What's included with the OAKTON pH/CON 700

  • Benchtop Meter
  • pH Electrode
  • Conductivity/Temperature Probe
  • Electrode Stand

Click on a category to view a selection of compatible accessories with the OAKTON pH/CON 700 Benchtop Meter, pH Electrode, Conductivity/Temp Probe and Probe Stand.

OAKTON WD-35608-72 Conductivity Probe for 700 & 2700 Meters, K=0.1, Epoxy Body WD-35608-72
This probe can be used for low conductivity measurements that are near or below 20mS. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-76 Conductivity Probe for 700 & 2700 Meters, K=1.0, Epoxy Body WD-35608-76
Having a 1.0K cell constant is ideal for midrange conductivity measurements. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-74 Conductivity Probe for 700 & 2700 Meters, K=1.0, Ultem Body WD-35608-74
Having a 1.0K cell constant is ideal for midrange conductivity measurements. For use with CON 700/2700 and PC 700/2700.




OAKTON WD-35608-78 Conductivity Probe for 700 & 2700 Meters, K=10, Epoxy Body WD-35608-78
This probe can be used for high conductivity measurements that are near or above 20mS. For use with CON 700/2700 and PC 700/2700.




Ask a question about OAKTON pH/CON 700 Benchtop Meter, pH Electrode, Conductivity/Temp Probe and Probe Stand

Customer Reviews for the OAKTON pH/CON 700

More OAKTON Products

Calibration Lab