OAKTON PC 450 WD-35630-90 pH/ORP/EC Meter Kit with Separate Probes

Model: PC 450 KIT | Order No: WD-35630-90

OAKTON PC 450 WD-35630-90 pH/ORP/EC Meter Kit with Separate Probes

Model: PC 450 KIT | Order No: WD-35630-90

Measures pH, mV, conductivity, TDS, salinity and temperature. Calibrate pH with up to 6 points from USA, NIST, DIN, PWB, and custom pH buffer sets.

Measures pH, mV, conductivity, TDS, salinity and temperature. Calibrate pH with up to 6 points from USA, NIST, DIN, PWB, and custom pH buffer sets.

Sale Price $1182.96 USD
Regular Price $1488.00 USD
Availability 1 to 2 Weeks
Quantity

OAKTON WD-35630-90 Offers

Features

  • Large, backlit LCD lets you view the main measurement simultaneously with temperature
  • Autocal feature for conductivity has one calibration point per range
  • ATC ensures measurement accuracy even in fluctuating temperatures
  • Ready (stability) indicator
  • Smart averaging
  • User-selectable °C/°F units
  • Hold function
  • Calibration alarm
  • Battery life-indicator and electrode status
  • Perform data logging with manual or timed collection of up to 500 data sets with real-time clock time/date stamp
  • Order optional data cable for USB and RS-232 connectivity
  • Select meter with combination pH/conductivity/temperature probe or separate pH and conductivity/temperature probes
  • Intuitive, user-friendly icons—electrode status displays pH slope
  • Extended battery life or optional universal power adapter
  • Grip-Clip electrode holder quickly and easily secures electrode to side of beaker or container
  • Waterproof and dustproof housing with IP67 rating
  • Built-in stand with wall mount allows for easy benchtop measurement or storage

OAKTON WD-35630-90 Specifications

pH
Range -2.00 to 16.00 pH
Resolution 0.01 pH
Accuracy ±0.01 pH
Calibration 6 points: USA, NIST, DIN, PWB & custom buffers
mV
Range ±2000 mV
Resolution 0.1 to 1 mV
Accuracy ±0.2 ±2 LSD or ±5% rdg.; whichever is greater
Calibration ±200 mV
Conductivity
Range 0 to 200 mS
Resolution 0.01 µS to 0.1 mS
Accuracy ±1% full scale
Calibration Auto/manual; one point per range
TDS
Range 0 to 200 ppt
Resolution 0.01 ppm to 0.1 ppt
Accuracy ±1% full scale
Calibration Auto/manual; one point per range
Temperature
Range -10.0 to 110.0°C
Resolution 0.1°C
Accuracy ±0.5°C
Calibration Offset 0.1°C increments
Temp. Compensation Automatic or manual
General Specifications
Power Supply 2 AA batteries, or optional power adapter
Dimensions 7 7/8" x 3 1/8" x 2 1/4" (20 x 8.3 x 5.7 cm)
Weight 1.4 lb (0.6 kg)

What's included with the OAKTON WD-35630-90

  • pH/ORP/EC Meter
  • Conductivity/temperature cell K = 1.0
  • pH probe
  • Grip-Clip holder
  • Two AA batteries
  • Calibration standards
  • Hard Carrying Case

Click on a category to view a selection of compatible accessories with the OAKTON PC 450 WD-35630-90 pH/ORP/EC Meter Kit with Separate Probes.

OAKTON WD-35420-01 Data Cable for RS232 Connectivity WD-35420-01
For use with WD-35630-10 & WD-35630-12.




OAKTON WD-35630-53 Data Cable for USB Connectivity WD-35630-53
USB Data Cable for use with WD-35630-10 & WD-35630-12.




OAKTON WD-35608-50 Replacement Conductivity Cell, K = 1.0 WD-35608-50
Ideal for the 11, 110, 700, and 2700 meters, this conductivity cell has a constant cell of K = 1.0 for midrange conductivity measurements and features built-in temperature compensation.




OAKTON WD-35608-51 Replacement Conductivity Cell, K = 10 WD-35608-51
OAKTON Conductivity Cell Probe for use with WD-35630-10. It features a 12mm diameter, a 3ft cable & a constant of 10.




OAKTON WD-35630-51 Replacement Combo pH/CON/ATC Probe WD-35630-51
For use with WD-35630-10.




OAKTON WD-35641-51 Replacement pH Electrode 35641-51
For use with WD-35630-10. It features a 12mm diameter, a 3ft cable & BNC connection.




Ask a question about OAKTON PC 450 WD-35630-90 pH/ORP/EC Meter Kit with Separate Probes

Customer Reviews for the OAKTON PC 450 KIT

OAKTON WD-35630-90 Offers

Features

  • Large, backlit LCD lets you view the main measurement simultaneously with temperature
  • Autocal feature for conductivity has one calibration point per range
  • ATC ensures measurement accuracy even in fluctuating temperatures
  • Ready (stability) indicator
  • Smart averaging
  • User-selectable °C/°F units
  • Hold function
  • Calibration alarm
  • Battery life-indicator and electrode status
  • Perform data logging with manual or timed collection of up to 500 data sets with real-time clock time/date stamp
  • Order optional data cable for USB and RS-232 connectivity
  • Select meter with combination pH/conductivity/temperature probe or separate pH and conductivity/temperature probes
  • Intuitive, user-friendly icons—electrode status displays pH slope
  • Extended battery life or optional universal power adapter
  • Grip-Clip electrode holder quickly and easily secures electrode to side of beaker or container
  • Waterproof and dustproof housing with IP67 rating
  • Built-in stand with wall mount allows for easy benchtop measurement or storage

OAKTON WD-35630-90 Specifications

pH
Range -2.00 to 16.00 pH
Resolution 0.01 pH
Accuracy ±0.01 pH
Calibration 6 points: USA, NIST, DIN, PWB & custom buffers
mV
Range ±2000 mV
Resolution 0.1 to 1 mV
Accuracy ±0.2 ±2 LSD or ±5% rdg.; whichever is greater
Calibration ±200 mV
Conductivity
Range 0 to 200 mS
Resolution 0.01 µS to 0.1 mS
Accuracy ±1% full scale
Calibration Auto/manual; one point per range
TDS
Range 0 to 200 ppt
Resolution 0.01 ppm to 0.1 ppt
Accuracy ±1% full scale
Calibration Auto/manual; one point per range
Temperature
Range -10.0 to 110.0°C
Resolution 0.1°C
Accuracy ±0.5°C
Calibration Offset 0.1°C increments
Temp. Compensation Automatic or manual
General Specifications
Power Supply 2 AA batteries, or optional power adapter
Dimensions 7 7/8" x 3 1/8" x 2 1/4" (20 x 8.3 x 5.7 cm)
Weight 1.4 lb (0.6 kg)

What's included with the OAKTON WD-35630-90

  • pH/ORP/EC Meter
  • Conductivity/temperature cell K = 1.0
  • pH probe
  • Grip-Clip holder
  • Two AA batteries
  • Calibration standards
  • Hard Carrying Case

Click on a category to view a selection of compatible accessories with the OAKTON PC 450 WD-35630-90 pH/ORP/EC Meter Kit with Separate Probes.

OAKTON WD-35420-01 Data Cable for RS232 Connectivity WD-35420-01
For use with WD-35630-10 & WD-35630-12.




OAKTON WD-35630-53 Data Cable for USB Connectivity WD-35630-53
USB Data Cable for use with WD-35630-10 & WD-35630-12.




OAKTON WD-35608-50 Replacement Conductivity Cell, K = 1.0 WD-35608-50
Ideal for the 11, 110, 700, and 2700 meters, this conductivity cell has a constant cell of K = 1.0 for midrange conductivity measurements and features built-in temperature compensation.




OAKTON WD-35608-51 Replacement Conductivity Cell, K = 10 WD-35608-51
OAKTON Conductivity Cell Probe for use with WD-35630-10. It features a 12mm diameter, a 3ft cable & a constant of 10.




OAKTON WD-35630-51 Replacement Combo pH/CON/ATC Probe WD-35630-51
For use with WD-35630-10.




OAKTON WD-35641-51 Replacement pH Electrode 35641-51
For use with WD-35630-10. It features a 12mm diameter, a 3ft cable & BNC connection.




Ask a question about OAKTON PC 450 WD-35630-90 pH/ORP/EC Meter Kit with Separate Probes

Customer Reviews for the OAKTON PC 450 KIT

More OAKTON Products

Calibration Lab