Accurate and reliable, this conductivity bench meter features a large LCD and a touch keypad. Effortlessly change the parameters, execute setup, and perform calibrations with the bench meter that provides repeatable and consistent measurement accuracy.
Accurate and reliable, this conductivity bench meter features a large LCD and a touch keypad. Effortlessly change the parameters, execute setup, and perform calibrations with the bench meter that provides repeatable and consistent measurement accuracy.
With a large LCD and a touch keypad, this conductivity bench meter features the I-Steward for repeatable and consistent measurement accuracy.
Features
Applications
Conductivity | |
Measurement Range | 0.001 to 19.99 μS/cm 20 to 199.9 μS/cm 200 to 1999 μS/cm 2.00 to 19.99 mS/cm 20.0 to 1000 mS/cm |
Resolution | 0.001 μS/cm minimum; auto-range |
Accuracy | ±0.5% reading ±2 least signficant digit |
Accuracy | ±0.01 pH |
Reference Temperature | 68°:f, 77°F (20°C, 25°C) |
Cell Constants | 0.01 to 10.00 cm-1 |
Temperature Compensation | Linear (0 to 10.0%/°C), off |
TDS | |
Measurement Range | 0.1 mg/L to 200 g/L |
Resolution | 0.01 mg/L minimum, auto-range |
Accuracy | ±0.5% reading ±2 least significant digit |
TDS Factor Range | Linear, 0.01 to 10.00, default 0.5 |
Resistivity | |
Measurement Range | 1 to 100 MΩ-cm |
Resolution | 0.01 Ω-cm auto-range |
Accuracy | ±0.5% reading ±2 least signficant digit |
Practical Salinity | |
Measurement Range | 0 to 100 psu |
Resolution | 0.01 psu minimum, auto-range |
Accuracy | ±0.5% reading ±2 least significant digit |
Temperature | |
Measurement Range | 23.0 to 230.0°F (-5.0 to 110.0°C) |
Resolution | 0.1°F (0.1°C) |
Accuracy | ±0.3°F (±0.3°C) |
General Specifications | |
Temperature Resolution | ±32°F (±0.1°C) |
Working Environment | 41 to 104°F (5 to 40°C), 80% RH, non-condensing |
Resistivity | Resolution: 0.01 Ω Measuring range: 1 Ω; 100 MΩ |
Display | LCD with backlight and one-line dot matrix |
Parameter | Conductivity |
pH Accuracy | 0.01 |
Power | AC adapter |
Dimensions | 8.3 x 2 x 5.6" (210 x 51 x 142 mm) |
Weight | 1.1 lb (0.5 kg) |
Conductivity | |
Measurement Range | 0.001 to 19.99 μS/cm 20 to 199.9 μS/cm 200 to 1999 μS/cm 2.00 to 19.99 mS/cm 20.0 to 1000 mS/cm |
Resolution | 0.001 μS/cm minimum; auto-range |
Accuracy | ±0.5% reading ±2 least signficant digit |
Accuracy | ±0.01 pH |
Reference Temperature | 68°:f, 77°F (20°C, 25°C) |
Cell Constants | 0.01 to 10.00 cm-1 |
Temperature Compensation | Linear (0 to 10.0%/°C), off |
TDS | |
Measurement Range | 0.1 mg/L to 200 g/L |
Resolution | 0.01 mg/L minimum, auto-range |
Accuracy | ±0.5% reading ±2 least significant digit |
TDS Factor Range | Linear, 0.01 to 10.00, default 0.5 |
Resistivity | |
Measurement Range | 1 to 100 MΩ-cm |
Resolution | 0.01 Ω-cm auto-range |
Accuracy | ±0.5% reading ±2 least signficant digit |
Practical Salinity | |
Measurement Range | 0 to 100 psu |
Resolution | 0.01 psu minimum, auto-range |
Accuracy | ±0.5% reading ±2 least significant digit |
Temperature | |
Measurement Range | 23.0 to 230.0°F (-5.0 to 110.0°C) |
Resolution | 0.1°F (0.1°C) |
Accuracy | ±0.3°F (±0.3°C) |
General Specifications | |
Temperature Resolution | ±32°F (±0.1°C) |
Working Environment | 41 to 104°F (5 to 40°C), 80% RH, non-condensing |
Resistivity | Resolution: 0.01 Ω Measuring range: 1 Ω; 100 MΩ |
Display | LCD with backlight and one-line dot matrix |
Parameter | Conductivity |
pH Accuracy | 0.01 |
Power | AC adapter |
Dimensions | 8.3 x 2 x 5.6" (210 x 51 x 142 mm) |
Weight | 1.1 lb (0.5 kg) |