Ideal for precise non-contact temperature measurement, this infrared thermometer kit features a two-piece sensor with a separate electronic box, programming keys, and a display. In addition, this kit includes a USB adapter and measures a range of -58 to 1787°F (-50 to 975°C) and features a selectable focus of 0.02" at 0.4" (0.6 mm at 10 mm).
Ideal for precise non-contact temperature measurement, this infrared thermometer kit features a two-piece sensor with a separate electronic box, programming keys, and a display. In addition, this kit includes a USB adapter and measures a range of -58 to 1787°F (-50 to 975°C) and features a selectable focus of 0.02" at 0.4" (0.6 mm at 10 mm).
Features
Applications
Temperature Range (Scalable Via Programming Keys or Software) | -58 to 1787°F (-50 to 975°C) |
Spectral Range | 8 to 14 µm |
Optical Resolution (90% Energy) | 15:1 (precision glass optics) |
CF Lens | 0.02" at 0.4" (0.6 mm at 10 mm) |
System Accuracy* at Ambient Temperature 73 ±9°F (23 ±5°C) *1)Whichever is greater and at object temperatures >32°F (>0°C), ε = 1 |
±1% or 1.8°F (1°C) |
Repeatability* at Ambient Temperature 73 ±9°F (23 ±5°C) *2)Whichever is greater and at object temperatures >32°F (>0°C), ε = 1 |
±0.5% or 0.9°F (0.5°C) |
Temperature Resolution (Display) | 0.1 K |
NETD* *3)At object temperatures >32°F (>0°C), ε = 1 and at time constant 200 ms and TObj 77°F (25°C) |
0.05 K |
Response Time | 150 ms (95%) |
Emissivity/Gain (Adjustable Via Programming Keys or Software) | 0.1 to 1.1 |
Transmissivity (Adjustable Via Programming Keys or Software) | 0.1 to 1.1 |
Signal Processing (Parameter Adjustable Via Programming Keys or Software, Respectively) | Peak hold, valley hold, average; extended hold function with threshold and hysteresis |
Software | optris® Compact Connect |
Output | Analog: Channel 1: 0/4 to 20 mA, 0 to 5/ 10 V, thermocouple J, K Channel 2: sensind head temperature -4 to 356°F (-20 to 180°C) as 0 to 5 V or 0 to 10 V, alarm output Alarm: 24 V / 50 mA (open collector) Impedances: mA maximum 500 Ω (with 8 to 36 V DC) mV minimum 100 kΩ load impedance thermocouple 20 Ω |
Inputs | Programmable functional inputs for external emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions) |
Current Draw | Maximum 100 mA |
Environmental Rating | IP 65 (NEMA-4) |
Temperature | Ambient*: Sensing head: -4 to 356°F (-20 to 180°C) Electronics: 32 to 185°F (0 to 85°C) Storage: Sensing head: -40 to 266°F (-40 to 130°C) Electronics: -40 to 185°F (-40 to 85°C) *4)The LCD displays capacity may be limited at ambient temperatures below 40°F (0°C) |
Relative Humidity | 10 to 95%, non condensing |
Vibration | IEC 60068-2-6 (sinus shaped) IEC 60068-2-64 (broadband noise) |
Shock | IEC 60068-2-27 (25 G and 50 G) |
Power Supply | 8 to 36 V DC |
Dimensions | Length: 4.8 x 2.76 x 1.18" (122 x 70 x 30 mm) Cable length: 9.8' (3 m) |
Weight | Sensing head: 1.4 oz (40 g) Electronics: 14.8 oz (420 g) |
Temperature Range (Scalable Via Programming Keys or Software) | -58 to 1787°F (-50 to 975°C) |
Spectral Range | 8 to 14 µm |
Optical Resolution (90% Energy) | 15:1 (precision glass optics) |
CF Lens | 0.02" at 0.4" (0.6 mm at 10 mm) |
System Accuracy* at Ambient Temperature 73 ±9°F (23 ±5°C) *1)Whichever is greater and at object temperatures >32°F (>0°C), ε = 1 |
±1% or 1.8°F (1°C) |
Repeatability* at Ambient Temperature 73 ±9°F (23 ±5°C) *2)Whichever is greater and at object temperatures >32°F (>0°C), ε = 1 |
±0.5% or 0.9°F (0.5°C) |
Temperature Resolution (Display) | 0.1 K |
NETD* *3)At object temperatures >32°F (>0°C), ε = 1 and at time constant 200 ms and TObj 77°F (25°C) |
0.05 K |
Response Time | 150 ms (95%) |
Emissivity/Gain (Adjustable Via Programming Keys or Software) | 0.1 to 1.1 |
Transmissivity (Adjustable Via Programming Keys or Software) | 0.1 to 1.1 |
Signal Processing (Parameter Adjustable Via Programming Keys or Software, Respectively) | Peak hold, valley hold, average; extended hold function with threshold and hysteresis |
Software | optris® Compact Connect |
Output | Analog: Channel 1: 0/4 to 20 mA, 0 to 5/ 10 V, thermocouple J, K Channel 2: sensind head temperature -4 to 356°F (-20 to 180°C) as 0 to 5 V or 0 to 10 V, alarm output Alarm: 24 V / 50 mA (open collector) Impedances: mA maximum 500 Ω (with 8 to 36 V DC) mV minimum 100 kΩ load impedance thermocouple 20 Ω |
Inputs | Programmable functional inputs for external emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions) |
Current Draw | Maximum 100 mA |
Environmental Rating | IP 65 (NEMA-4) |
Temperature | Ambient*: Sensing head: -4 to 356°F (-20 to 180°C) Electronics: 32 to 185°F (0 to 85°C) Storage: Sensing head: -40 to 266°F (-40 to 130°C) Electronics: -40 to 185°F (-40 to 85°C) *4)The LCD displays capacity may be limited at ambient temperatures below 40°F (0°C) |
Relative Humidity | 10 to 95%, non condensing |
Vibration | IEC 60068-2-6 (sinus shaped) IEC 60068-2-64 (broadband noise) |
Shock | IEC 60068-2-27 (25 G and 50 G) |
Power Supply | 8 to 36 V DC |
Dimensions | Length: 4.8 x 2.76 x 1.18" (122 x 70 x 30 mm) Cable length: 9.8' (3 m) |
Weight | Sensing head: 1.4 oz (40 g) Electronics: 14.8 oz (420 g) |