Designed for easy integration, the CM sensor can easily replace traditional contact probes if your application is susceptible to noise. The onboard electronics are protected by a rugged IP65 (NEMA-4) stainless steel housing, allowing the sensor to function in ambient temperatures to 160°F (70°C) without cooling.
Designed for easy integration, the CM sensor can easily replace traditional contact probes if your application is susceptible to noise. The onboard electronics are protected by a rugged IP65 (NEMA-4) stainless steel housing, allowing the sensor to function in ambient temperatures to 160°F (70°C) without cooling.
The RS232 digital interface allows the user to configure all programmable sensor variables with the powerful DataTemp Multidrop software. Includes a 24 volt DC alarm output triggered by target temperature or head ambient temperature, peak hold, valley hold or variable averaging signal processing, adjustable target emissivity settings and adjustable window transmissivity setting. The built-in sensor health LED provides a convenient on-line indicator of the sensor's operating status and aids in troubleshooting initial sensor set up.
Features
Applications
Spectral Response | 8 to 14 μm |
Temperature Range | -4 to 932°F (-20 to 500°C) |
Optical Resolution | 13:1 |
Accuracy (mV) | mV: ±1.5% of reading or ±2°C, whichever is greater t/c: ±1.5% of reading ±2°C or ±4°C, whichever is greater |
Repeatability | Digital and voltage: ±0.5% of reading or ±2°C, whichever is greater t/c: ±0.5% of reading ±1°C or ±2°C, whichever is greater |
Temperature Resolution | 0.1°C |
Response Time (95%) | 150 mSec |
Emissivity | 0.10 to 1.10 (adjustable) |
Transmissivity | 0.10 to 1.00 (adjustable) |
Signal Processing | Peak hold, valley hold, variable averaging |
Self Diagnostics/Sensor Status | Normal operation, alarm, out of range, unstable, sensor fault |
Bore-Sight Tolerance | 3° @ focal point |
Analog Outputs | Model specific Type J, Type K or scaleable 0 to 5 V voltage output |
Cable Length | 3.3' (1 m) standard 9.8' (3 m) cables optional |
Thermocouple Output Impedance | 100 Ω |
Voltage Output Minimum Load Impedance | 50 KΩ |
Power Supply | 24 VDC ±20% @ 20mA |
Digital Output | Two-way RS232 digital output |
Alarm Output | Transistor, 24 VDC @ 20 mA |
Environmental Rating | IP65 (NEMA-4) |
Ambient Temperature Range | 14 to 160°F (-10 to 70°C) |
Cable Temperature Range | -22 to 220°F (-30 to 105°C) |
Storage Temperature | -4 to 185°F (-20 to 85°C) |
Relative Humidity | 10 to 95%, non-condensing |
Shock | IEC 68-2-27 (MIL STD 810D) 50 g's, 11 mSec, any axis |
Vibration | IEC 68-2-27 (MIL STD 810D) 3 g's, any axis, 11–200 Hz |
Weight | 1 m cable model: <7 oz (200 g) |
Spectral Response | 8 to 14 μm |
Temperature Range | -4 to 932°F (-20 to 500°C) |
Optical Resolution | 13:1 |
Accuracy (mV) | mV: ±1.5% of reading or ±2°C, whichever is greater t/c: ±1.5% of reading ±2°C or ±4°C, whichever is greater |
Repeatability | Digital and voltage: ±0.5% of reading or ±2°C, whichever is greater t/c: ±0.5% of reading ±1°C or ±2°C, whichever is greater |
Temperature Resolution | 0.1°C |
Response Time (95%) | 150 mSec |
Emissivity | 0.10 to 1.10 (adjustable) |
Transmissivity | 0.10 to 1.00 (adjustable) |
Signal Processing | Peak hold, valley hold, variable averaging |
Self Diagnostics/Sensor Status | Normal operation, alarm, out of range, unstable, sensor fault |
Bore-Sight Tolerance | 3° @ focal point |
Analog Outputs | Model specific Type J, Type K or scaleable 0 to 5 V voltage output |
Cable Length | 3.3' (1 m) standard 9.8' (3 m) cables optional |
Thermocouple Output Impedance | 100 Ω |
Voltage Output Minimum Load Impedance | 50 KΩ |
Power Supply | 24 VDC ±20% @ 20mA |
Digital Output | Two-way RS232 digital output |
Alarm Output | Transistor, 24 VDC @ 20 mA |
Environmental Rating | IP65 (NEMA-4) |
Ambient Temperature Range | 14 to 160°F (-10 to 70°C) |
Cable Temperature Range | -22 to 220°F (-30 to 105°C) |
Storage Temperature | -4 to 185°F (-20 to 85°C) |
Relative Humidity | 10 to 95%, non-condensing |
Shock | IEC 68-2-27 (MIL STD 810D) 50 g's, 11 mSec, any axis |
Vibration | IEC 68-2-27 (MIL STD 810D) 3 g's, any axis, 11–200 Hz |
Weight | 1 m cable model: <7 oz (200 g) |