Measure exhaust gasses from forklift engines with this combustion analyzer kit. In addition, this kit includes a combustion analyzer, three gas sensors, a 7" (180 mm) probe, a holster, a water trap, a power supply, a USB cable, a wireless communication module, a quick start guide, a calibration certificate, and a hard case.
Measure exhaust gasses from forklift engines with this combustion analyzer kit. In addition, this kit includes a combustion analyzer, three gas sensors, a 7" (180 mm) probe, a holster, a water trap, a power supply, a USB cable, a wireless communication module, a quick start guide, a calibration certificate, and a hard case.
Compact and durable, this combustion analyzer kit features pre-calibrated field-replaceable cells and sensors to expand measurement capability. Additionally, this kit features CO sensor measurements up to 8000 ppm and automatic logging and report creation through the app or software.
Features
Applications
Air Temperature | Sensor: NTC or TcK Measuring range: -4 to 248°F (-20 to 120°C) Resolution: 0.1°F (0.1°C) Accuracy: ±3.6°F (±2°C) |
CO | Sensor: Electrochemical Measuring range: 0 to 8000 ppm Resolution: 1 ppm Accuracy: ±8 ppm <160 ppm ±5% rdg up to 2000 ppm ±10 rdg >2000 ppm T90 response time: <40 seconds |
CO2 | Sensor: Calculated Measuring range: 0 to 99.9% Resolution: 0.1% |
Connection | Wireless: class 2 range, range frequency from 2402 to 2480 MHz with a transmit power of 1 dBm Range up to 50' (15 m), depending on smartphone radio strength Minimum required versions: Android 5.0, iOS 12.4, BLE 4.0- USB |
Differential Temperature | Sensor: Calculated Measuring range: 0 to 2282°F (0 to 1250°C) Resolution: 0.1°F (0.1°C) |
Dimensions | 7.5 x 3.5 x 4.9" (19.4 x 9.9 x 4.9 cm) |
Display | Color touch screen with graphing; Size: 480 x 272 pixels |
Efficiency | Sensor: Calculated Measuring range: 0 to 100% (Gross/HHV) Resolution: 0.1% |
Efficiency (condensation) | Sensor: Calculated Measuring range: 0 to 125% (Net/LHV) (Gross/HHV) Resolution: 0.1% |
Environmental Conditions of Use | Temperature: From 23 to 11°F (-5 to 45°C) Hygrometry: In non-condensing conditions (<85% RH) Maximum altitude: 6561' (2000 m) |
European Union Directives | 2014/53/EU (RED); 2015/863 EU (RoHS 3) |
Excess Air | Sensor: Calculated Measuring range: 0 to 999% Resolution: 1% |
Flue Temperature | Sensor: TcK Measuring range: -4 to 2282°F (-20 to 1250°C) Resolution: 0.1°F (0.1°C) Accuracy: ±3.6°F or ±0.5% rdg (±2°C or ±0.5% rdg) |
High Accuracy Draft | Sensor: Semiconductor Measuring range: 500 Pa Resolution: 0.1 Pa Accuracy: ±0.5 Pa <10 Pa ±3 Pa up to 150 Pa ±2% rdg >150 Pa |
Keypad | 1 On-Off key |
Languages | English, French, German, Spanish, Italian, Portuguese, Chinese |
Low NO | Sensor: Electrochemical Measuring range: 0 to 300 ppm Resolution: 0.1 ppm Accuracy: ±1.5 ppm <30 ppm ±5% rdg >30 ppm T90 response time: <40 seconds |
Low NOx | Sensor: Calculated Measuring range: 0 to 450 ppm Resolution: 0.1 ppm |
Material | ABS-PC |
NO | Sensor: Electrochemical Measuring range: 0 to 5000 ppm Resolution: 1 ppm Accuracy: ±5 ppm <100 ppm ±5% rdg >100 ppm T90 response time: <40 seconds |
NOx | Sensor: Calculated Measuring range: 0 to 7500 ppm Resolution: 1 ppm |
O2 | Sensor: Electrochemical Measuring range: 0 to 25% Resolution: 0.01% Accuracy: ±0.2% vol T90 response time: <30 seconds |
Power | Supply: Rechargeable battery, USB power supply Li-Ion 5100 mA/h 3.6 V battery/power supply voltage of the mains unit: 100 to 240 V AC, 50 to 60 Hz Mains unit: 5 V DC/2 A Battery life: >8 hours; Charging time: Fully charge: <6.5 hours; 50%: <2.5 hours |
Pressure/Draft | Sensor: Semiconductor Measuring range: -80 to 80 inH2O -200 to 200 mbar Resolution: 0.001 inH2O 0.01 mbar Accuracy: ±1% rdg ±0.012 inH2O ±1% rdg ±0.03 mbar |
Protection | IP42 |
Regulations | EN 50379-1 and EN 50379-2; UNI 7129; UNI 11137; UNI 10389; UNI 10845; UL & cUL Certification; BS 7967:2015; BS EN 50543:2011; UNE 60670-10; ES.02173.ES |
Stack Gas Velocity | Sensor: Calculated Measuring range: 0 to 19,500 fpm 0 to 99 m/s Resolution: 1 fpm 0.1 m/s |
Storage Temperature | From -4 to 122°F (-20 to 50°C) |
Weight | 12 oz (350 g) |
Air Temperature | Sensor: NTC or TcK Measuring range: -4 to 248°F (-20 to 120°C) Resolution: 0.1°F (0.1°C) Accuracy: ±3.6°F (±2°C) |
CO | Sensor: Electrochemical Measuring range: 0 to 8000 ppm Resolution: 1 ppm Accuracy: ±8 ppm <160 ppm ±5% rdg up to 2000 ppm ±10 rdg >2000 ppm T90 response time: <40 seconds |
CO2 | Sensor: Calculated Measuring range: 0 to 99.9% Resolution: 0.1% |
Connection | Wireless: class 2 range, range frequency from 2402 to 2480 MHz with a transmit power of 1 dBm Range up to 50' (15 m), depending on smartphone radio strength Minimum required versions: Android 5.0, iOS 12.4, BLE 4.0- USB |
Differential Temperature | Sensor: Calculated Measuring range: 0 to 2282°F (0 to 1250°C) Resolution: 0.1°F (0.1°C) |
Dimensions | 7.5 x 3.5 x 4.9" (19.4 x 9.9 x 4.9 cm) |
Display | Color touch screen with graphing; Size: 480 x 272 pixels |
Efficiency | Sensor: Calculated Measuring range: 0 to 100% (Gross/HHV) Resolution: 0.1% |
Efficiency (condensation) | Sensor: Calculated Measuring range: 0 to 125% (Net/LHV) (Gross/HHV) Resolution: 0.1% |
Environmental Conditions of Use | Temperature: From 23 to 11°F (-5 to 45°C) Hygrometry: In non-condensing conditions (<85% RH) Maximum altitude: 6561' (2000 m) |
European Union Directives | 2014/53/EU (RED); 2015/863 EU (RoHS 3) |
Excess Air | Sensor: Calculated Measuring range: 0 to 999% Resolution: 1% |
Flue Temperature | Sensor: TcK Measuring range: -4 to 2282°F (-20 to 1250°C) Resolution: 0.1°F (0.1°C) Accuracy: ±3.6°F or ±0.5% rdg (±2°C or ±0.5% rdg) |
High Accuracy Draft | Sensor: Semiconductor Measuring range: 500 Pa Resolution: 0.1 Pa Accuracy: ±0.5 Pa <10 Pa ±3 Pa up to 150 Pa ±2% rdg >150 Pa |
Keypad | 1 On-Off key |
Languages | English, French, German, Spanish, Italian, Portuguese, Chinese |
Low NO | Sensor: Electrochemical Measuring range: 0 to 300 ppm Resolution: 0.1 ppm Accuracy: ±1.5 ppm <30 ppm ±5% rdg >30 ppm T90 response time: <40 seconds |
Low NOx | Sensor: Calculated Measuring range: 0 to 450 ppm Resolution: 0.1 ppm |
Material | ABS-PC |
NO | Sensor: Electrochemical Measuring range: 0 to 5000 ppm Resolution: 1 ppm Accuracy: ±5 ppm <100 ppm ±5% rdg >100 ppm T90 response time: <40 seconds |
NOx | Sensor: Calculated Measuring range: 0 to 7500 ppm Resolution: 1 ppm |
O2 | Sensor: Electrochemical Measuring range: 0 to 25% Resolution: 0.01% Accuracy: ±0.2% vol T90 response time: <30 seconds |
Power | Supply: Rechargeable battery, USB power supply Li-Ion 5100 mA/h 3.6 V battery/power supply voltage of the mains unit: 100 to 240 V AC, 50 to 60 Hz Mains unit: 5 V DC/2 A Battery life: >8 hours; Charging time: Fully charge: <6.5 hours; 50%: <2.5 hours |
Pressure/Draft | Sensor: Semiconductor Measuring range: -80 to 80 inH2O -200 to 200 mbar Resolution: 0.001 inH2O 0.01 mbar Accuracy: ±1% rdg ±0.012 inH2O ±1% rdg ±0.03 mbar |
Protection | IP42 |
Regulations | EN 50379-1 and EN 50379-2; UNI 7129; UNI 11137; UNI 10389; UNI 10845; UL & cUL Certification; BS 7967:2015; BS EN 50543:2011; UNE 60670-10; ES.02173.ES |
Stack Gas Velocity | Sensor: Calculated Measuring range: 0 to 19,500 fpm 0 to 99 m/s Resolution: 1 fpm 0.1 m/s |
Storage Temperature | From -4 to 122°F (-20 to 50°C) |
Weight | 12 oz (350 g) |