Ideal for potable water and applications where electricity and power supply are unavailable, this electromagnetic flow meter has a measuring range of 0.7 to 39 ft/second (0.2 to 12 m/second) bi-directional. In addition, its long life span minimizes maintenance and enhances smart measurements’ productivity in field instruments.
Ideal for potable water and applications where electricity and power supply are unavailable, this electromagnetic flow meter has a measuring range of 0.7 to 39 ft/second (0.2 to 12 m/second) bi-directional. In addition, its long life span minimizes maintenance and enhances smart measurements’ productivity in field instruments.
Widely used for high-pressure applications, this utility electromagnetic flow meter provides highly accurate and reliable measurements and measures the flow rate for various conductive liquids. In addition, it operates on the principle of Faraday’s Law of Electromagnetic Induction and is designed for applications where electricity and power supply availability is unavailable.↵
Features
Applications
Accuracy | ±0.5% (Standard) |
Measuring Range | 0.2 to 12 m/second bi-directional |
Repeatability | ±0.2% of span |
Process | Pressure: 150# ANSI or 300# ANSI flange Integral temperature: -40 to 250°F (-40 to 120°C) Remote temperature: -40 to 350°F (-40 to 180°C) |
Operating Conditions | Temperature: -40 to 131°F (-40 to 55°C) Humidity: 5 to 95% RH non-condensing |
Size | ½ to 28" (10 to 700 mm) |
Output | 4 to 20 mA, pulse, HART modbus RS485 |
Transmitter | Direct mount |
Power Supply | 16 to 60 V DC |
Protection Class | IP65 (Standard) |
End Connection | ANSI flange |
Electrode Material | 316 SS |
Measuring Tube Material | SS304 |
Housing Material | Carbon steel |
Sensor Lining | Polypropylene |
Display | Version: Integral or remote Type: 16 characters x 2 row LCD, 5 digit flow rate and 8 digit totalizer |
Terminal Connector | 18 to 22 AWG wire |
Units | Flow rate: LPS, LPM, LPH, LPD Mlps, Mlpm, Mlph, Mlpd cc/s, cc/m, cc/h, cc/d m3/s, m3/m, m3/h, m3/d kg/s, kg/m, kg/h, kg/d t/s, t/m, t/h, t/d gps, gpm, gph, gpd Mgps, Mgpm, Mgph, Mgpd lgps, lgpm, lgph, lgpd lMgps, lMgpm, lMgph, lMgpd ft3/s, ft3/m, ft3/h, ft3/d lb/s, lb/m, lb/h, lb/d Totalizer: L, Ml, m3 Ml L, Ml, cc, m3 L, Ml, m3 kg, t T G, ft3 Mg lg, ft3 lMg g, lg, ft3 lb |
Dimensions | Overall: 10.75 x 10 x 23" (272 x 250 x 287 mm) Cable length: 30' (9.14 m) standard, up to 150' (45.72 m) maximum |
Accuracy | ±0.5% (Standard) |
Measuring Range | 0.2 to 12 m/second bi-directional |
Repeatability | ±0.2% of span |
Process | Pressure: 150# ANSI or 300# ANSI flange Integral temperature: -40 to 250°F (-40 to 120°C) Remote temperature: -40 to 350°F (-40 to 180°C) |
Operating Conditions | Temperature: -40 to 131°F (-40 to 55°C) Humidity: 5 to 95% RH non-condensing |
Size | ½ to 28" (10 to 700 mm) |
Output | 4 to 20 mA, pulse, HART modbus RS485 |
Transmitter | Direct mount |
Power Supply | 16 to 60 V DC |
Protection Class | IP65 (Standard) |
End Connection | ANSI flange |
Electrode Material | 316 SS |
Measuring Tube Material | SS304 |
Housing Material | Carbon steel |
Sensor Lining | Polypropylene |
Display | Version: Integral or remote Type: 16 characters x 2 row LCD, 5 digit flow rate and 8 digit totalizer |
Terminal Connector | 18 to 22 AWG wire |
Units | Flow rate: LPS, LPM, LPH, LPD Mlps, Mlpm, Mlph, Mlpd cc/s, cc/m, cc/h, cc/d m3/s, m3/m, m3/h, m3/d kg/s, kg/m, kg/h, kg/d t/s, t/m, t/h, t/d gps, gpm, gph, gpd Mgps, Mgpm, Mgph, Mgpd lgps, lgpm, lgph, lgpd lMgps, lMgpm, lMgph, lMgpd ft3/s, ft3/m, ft3/h, ft3/d lb/s, lb/m, lb/h, lb/d Totalizer: L, Ml, m3 Ml L, Ml, cc, m3 L, Ml, m3 kg, t T G, ft3 Mg lg, ft3 lMg g, lg, ft3 lb |
Dimensions | Overall: 10.75 x 10 x 23" (272 x 250 x 287 mm) Cable length: 30' (9.14 m) standard, up to 150' (45.72 m) maximum |