Teledyne LeCroy T3PM1100 Single Phase Digital Power Meter, 5", 100 kHz

Model: T3PM1100

Teledyne LeCroy T3PM1100 Single Phase Digital Power Meter, 5", 100 kHz

Model: T3PM1100

Work with clear visibility of your measurement results with this reliable meter that features a 5" (127 mm) LCD and an input bandwidth of 0.1 Hz ~ 100 kHz. In addition, this meter offers display waveform (voltage/current/power), the integration measurement function, harmonic measurement, and analysis of each order.

Work with clear visibility of your measurement results with this reliable meter that features a 5" (127 mm) LCD and an input bandwidth of 0.1 Hz ~ 100 kHz. In addition, this meter offers display waveform (voltage/current/power), the integration measurement function, harmonic measurement, and analysis of each order.

Your Price $2350.00 USD
Availability 15+ Weeks
Quantity

Teledyne LeCroy T3PM1100 Offers

Measure the power consumption of products and standby power consumption of low-power devices with this meter. In addition, this power meter provides RS-232C, USB device (virtual COM), and LAN communication interfaces for remote control applications.

Features

  • 5" (127 mm) large TFT LCD display
  • Two numerical display modes along with a waveform display of various parameters
  • Automatic Level-changing feature for integration function
  • External current sensor input terminal
  • Standard interfaces: USB, LAN, RS-232C
  • Clear visibility of your measurement results
  • Choose the best display mode for your measurement requirements
  • Achieve faster measurement results without worrying about power level changes
  • Extends the current measurement capability for various application requirements
  • Remote control of your measurements
  • Reliable product gives peace of mind
  • DC, 0.1 Hz to 100 kHz voltage/current test bandwidth
  • General Mode: Displays two main test items + eight secondary test items
  • Simple mode: Displays the test values of four main test items
  • Waveform display: V (Voltage), I (Current), P (Power)
  • The current/voltage can be measured to a deformed wave with CF of three, and the half-range CF can reach 6 or 6 A
  • Meets the IEC 61000-4-7 harmonics measurement requirements (50/60 Hz)
  • 50th order of harmonic measurement and analysis (value and bar graph)
  • Integration function supports automatic levelchanging
  • Full five-digit measurement
  • Maximum accuracy of 0.1% of reading + 0.05% of range
  • Selectable boot settings (Previous/default)
  • Waveform display up to 10 kHz along with harmonic bar and list table

Various display modes

The results of parameter measurement are displayed in numerical as well as graphical formats. Numerical format offers general and simple mode to display various parameters. The general mode can display 10 measurement parameters (Two main measurements + 8 monitoring measurements), and the simple mode can display four measurement parameters. These displayed parameters can be arbitrarily selected from 25 power ­parameters according to user requirements. The graphical format can display waveforms of voltage, current and power. The horizontal scale can be adjusted from 25 μs/div to 1 s/div (depends on data update rate). Three magnification levels for waveform are also provided for users to select.

In the harmonic measurement, the measurement result of each order of harmonics can be displayed by bar graphs, and a specific order can be specified for observation. The relevant values of each order of harmonics such as voltage, current, power, voltage distortion ratio, current distortion ratio, power distortion ratio, voltage phase angle, current phase angle can be recorded and displayed.

Rich measurement parameters

This digital power meter provides various measurement functions such as voltage, current, frequency, effective power, apparent power, reactive power, power factor, crest factor, total harmonic distortion, and maximum current ratio. This powere meter is also equipped to measure time integral of power or current for the DUT. Users can set a time window to perform instantaneous power integration at specified intervals and then divide value by total time period to obtain the average power of the DUT.

During integration measurement, this power meter supports automatic level changing function according to DUT power level in order to obtain accurate results.

Auxiliary measurement functions

This digital power meter has rich set of auxiliary measurement functions. High voltage measurements can be done using VT rate setting along with an external voltage potential transformer. To measure currents above 20 A a current transformer can be used and the type of CT determines the instrument settings. When a voltage output type CT is used, measurement can be conducted through the external current sensor input terminals EXT1/EXT2.

In addition, this power meter provides four sets of panel settings for storage/recall and memory for storing 10,000 sets of measurement values. The measurement storage can log the measurement results based upon the update rate or a self-defined time interval to facilitate the subsequent analysis. The USB host on the front panel supports screen capture, measurement value storage, and digital power meter firmware update. When a current output type CT is used, the CT can be directly connected to current input terminal on the rear panel and setting the appropriate CT ratio state in the Ratio configuration menu.

Applications

  • Power supplies
  • Transformers
  • Motors
  • Electrical equipment
  • Other equipment with low standby power

Teledyne LeCroy T3PM1100 Specifications

Input
Type Voltage: Floating input through resistive voltage divider
Current: Floating input through shunt
Measuring Range Voltage: 15, 30, 60, 150, 300, and 600 V
Current:
Direct input: 5, 10, 20, 50, 100, and 200 mA/0.5, 1, 2, 5, 10, and 20 A
Sensor input:
EXT 1: 2.5, 5 , and 10 V
EXT 2: 50, 100, 200, and 500 mV/1 and 2 V
Impedance Voltage: input resistance: 2 MΩ
Current:
Direct input range 5 ~ 200 mA: input resistance: 505 mΩ
Direct input range 0.5 ~ 20 A: input resistance: 5 mΩ
Sensor input:
Input range 2.5 ~ 10 V (EXT1): Input resistance: 100 kΩ
Input range 50 mV ~ 2 V (EXT2): Input resistance: 20 kΩ
Continuous Maximum Allowable Input Voltage: Peak value of 1.5 kV or RMS value of 1 kV, whichever is less
Current:
Direct input range 5 ~ 200 mA: Peak value of 30 A or RMS value of 20 A, whichever is less
Direct input range 0.5 ~ 20 A: Peak value of 100 A or RMS value of 30 A, whichever is less
Sensor input: Peak value less than or equal to five times of the rated range
Bandwidth DC, 0.1 Hz ~ 100 kHz
Continuous Maximum Common-Mode Voltage 600 Vrms, CAT II
Filter Line and frequency: Select OFF or ON (cut off frequency of 500 Hz)
A/D Converter Simultaneous conversion voltage and current inputs
Resolution 16 bits
Maximum conversion rate approximately 300 kHz
Voltage and Current Accuracy
Requirements Temperature: 23 ± 5°C
Humidity: 30 ~ 75 % RH
Input waveform: Sine wave crest factor = 3
Common-mode voltage: 0 V
Number of displayed digits: 5 digits
Frequency filter: Turn on to measure voltage or current of 200 Hz or less
Warm-up time: 30 minutes
Update interval: 250 ms
Accuracy DC: ± (0.1 % of reading + 0.2 % of range)
0.1 Hz ≤ f <45 Hz: ± (0.1 % of reading + 0.2 % of range)
45 Hz &le f ≤66 Hz: ± (0.1 % of reading + 0.05 % of range)
66 Hz < f &le1 kHz: ± (0.1 % of reading + 0.2 % of range)
1 kHz < f ≤10 kHz: ± (0.07 *f) % of reading + 0.3 % of range)
10 < f ≤100 kHz: ± (0.5 % of reading + 0.5 % of range) ± [{0.04 x (f-10)} % of reading]
When the Crest Factor is set to 6 or 6 A: Accuracy obtained by doubling the measurement range error for the accuracy when the crest factor is set to 3
Changes caused by data update interval: When the data update interval is 100 ms, and auto, add 0.05 % of reading to the 0.1 Hz to 1 kHz accuracy
Temperature Coefficient Add: ±0.03 % of reading/°C within the range 5 to 18°C or 28 to 40°C
When the Line Filter is Turned ON 45 ~ 66 Hz: Add 0.2 % of reading
<45 Hz: Add 0.5 % ofreading
Accuracy when the Crest Factor is set to 6 or 6 A Accuracy obtained by doubling the measurement range error for the accuracy when the crest factor is set to 3
Accuracy Changes Caused by Data Update Interval When the data update interval is 100 ms, and Auto, add 0.05 % of readingto the 0.1 Hz to 1 kHz accuracy
Influence of Temperature Changes After Zero-Level Compensation or Range Change DC voltage accuracy: Add 0.02 % of range/°C
DC current accuracies:
5/10/20/50/100/ and 200 mA ranges: Add 5 μA/°C
0.5/1/2/5/10/ and 20 A ranges: Add 500 μA/°C
External current sensor input (/EXT 1): Add 1 mV/°C
External current sensor input (/EXT2): Add 50 μV/°C
Active Power Accuracy
Requirements Same as the conditions for voltage and current
Power factor
Accuracy DC: (0.1 % of reading + 0.2 % of range)
0.1 Hz ≤ f <45 Hz: ± (0.3 % of reading + 0.2 % of range)
45 Hz ≤ f <66 Hz: ± (0.1 % of reading + 0.05 % of range)
66 Hz < f ≤1 kHz: ± (0.2 % of reading + 0.2 % of range)
1 kHz < f ≤10 kHz: ± (0.1 % of reading + 0.3 % of range) ± [{0.067 x (f-1)} % of reading]
10 kHz < f ≤100 kHz: ± (0.5 % of reading + 0.5 % of range) ± [{0.09 x (f-10)} % of reading]
When the crest factor is set to 6 or 6 A: Accuracy obtained by doubling the measurement range error for the accuracy when the crest factor is set to 3
f Apparent power S: Voltage accuracy + current accuracy
Reactive power Q: Accuracy of apparent power + (√1.0004 - λ2) - (√1 - λ2) x 100 %
Power factor Λ: ± [(λ-λ/1.0002) + [λcosø-cos{ø+sin-1 (influence from the power factor when λ = 0 %/100)} I ] ±1 digit when voltage and current are at the measurement range rated input
Phase difference Φ: ± [ I ø-cos-1 (λ/1.0002) I + sin-1 (influence from the power factor when λ = 0 % / 100)] ±1 digit when voltage and current are at the measurement range rated input
Changes caused by data update interval: When the data update interval is 100 ms, and Auto, add 0.05 % of reading to the 0.1 Hz to 1 kHz accuracy
Influence of Power Factor When power factor (λ) = 0 (S: apparent power)
±0.1 % of S for 45 Hz ≤ f ≤66 Hz
± {(0.1 + 0.15 x f) % of S} for up to 100 kHz as reference data
f is frequency of input signal in kHz
when 0 < λ < 1 (Φ: phase angle of the voltage and current) (power reading) x [(power reading error %) + (power range %) x (power range/indicated apparent power value) + {tanΦ x (influence when λ = o) %}]
When the Line Filter is Turned ON 45 ~ 66 Hz: Add 0.3 % of reading
<45 Hz: Add 1 % of reading
Temperature Coefficient Same as the temperature coefficient for voltage and current
Frequency Measurement
Measurement Parameter: Voltage and current
Frequency range:
Data update interval: Measurement frequency range
0.1 s: 20 Hz ≤ f ≤100 kHz
0.25 s: 10 Hz ≤ f ≤100 kHz
0.5 s: 5 Hz ≤ f ≤100 kHz
1 s: 2 Hz ≤ f ≤100 kHz
2 s: 1 Hz ≤ f ≤100 kHz
5 s: 0.5 Hz ≤ f ≤100 kHz
10 s: 0.2 Hz ≤ f ≤100 kHz
20 s: 0.1 Hz ≤ f ≤100 kHz
Auto (*): 0.1 Hz ≤ f ≤100 kHz
(*) Lower frequency measurement limit is defined by timeout setting
Timeout: Lower frequency limit
1 s: 2 Hz
5 s: 0.5 Hz
10 s: 0.2 Hz
20 s: 0.1 Hz
Range: Auto switching between six frequencies: 100 mHz, 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, and 100 kHz
Filter Select OFF or ON (cut off frequency of 500 Hz)
Accuracy Requirements: Input signal level should be greater than 30% of the measurement range if the crest factor is set to 3. (60 % or more if the crest factor is set to 6 or 6 A) and frequency filter should be ON when the frequency of the signal is less than 200 Hz
± (0.06 % of reading)
Integration
Mode Selectable manual integration mode, standard integration mode, or repetitive integration mode
Timer Automatically stop integration by setting a timer
Selectable range: 0 hours 0 minutes 0 seconds to 9999 hours 59 minutes 59 seconds
Accuracy ± (Power accuracy (or current accuracy) + 0.1 % of reading), fixed range
Timer Accuracy ±0.02 %
Harmonic Measurement
Measured Item: Voltage, current, power
Method: Zero-cross simultaneous calculation method
Frequency Range 10 Hz to 1.2 kHz
FFT Data Length 1024
4096 (Auto switch when both 50/60 Hz and update rate >0.1 s conditions are met)
Sample Rate, Window Width, and Upper Limit of Analysis Orders Fundamental frequency:

10 to 44 Hz:
Sample rate: f x 1024
Window width: 1
Upper limit of analysis orders: 50

45 to 55 Hz:
Sample rate: f x 512
Window width: 10
Upper limit of analysis orders: 50

54 to 66 Hz:
Sample rate: f x 512
Window width: 12
Upper limit of analysis orders: 50

67 to 150 Hz:
Sample rate: f x 512Window width: 2
Upper limit of analysis orders: 32

150 to 300 Hz:
Sample rate: f x 256
Widnow width: 4
Upper limit of analysis orders: 16

300 to 600 Hz: Sample rate: f x 128
Window width: 8
Upper limit of analysis orders: 8

600 to 1200 Hz:
Sample rate: f x 64
Window width: 16
Upper limit of analysis orders: 4
Accuracy Frequency:

10 Hz ≤ f <45 Hz:
Voltage: 0.15 % of reading + 0.35 % of range
Current: 0.15 % of reading + 0.35 % of range
Power: 0.35 % of reading + 0.5 % of range

45 Hz ≤ f <440 Hz:
Voltage: 0.15 % of reading + 0.35 % of range
Current: 0.15 % of reading + 0.35 % of range
Power: 0.25 % of reading + 0.5 % of range

440 Hz ≤ f <1.2 kHz:
Voltage: 0.2 % of reading + 0.35 % of range
Current: 0.2 % of reading + 0.35 % of range
Power: 0.4 % of reading + 0.5 % of range
General Specifications
Condition Specification:
Temperature: 23°C ± 5°C
Humidity: <80 % RH (non-condensing)

Operation: Temperature 32°F ~ 104°F (0°C ~ 40°C)
30 ~ 40°C, relative humidity <70 % RH (non-condensing)
>40°C, relative humidity <50 % RH (non-condensing)
Indoor use only
Altitude: <2000 meters
Pollution degree 2

Storage: Temperature -40 to 158°F (-40°C ~ 70°C)
Humidity: <90 % RH (non-condensing)
Power Source AC 100 to 240 V, 50 to 60 Hz; consumption maximum 30 VA
Dimensions 10.55 x 4.21 x 14.92", w/t bumpers (268 x 107 x 379 mm, w/t bumpers)
Weight Approximately 6.39 lbs (2.9 kg)
Click here for complete specifications on the Teledyne LeCroy T3PM1100

What's included with the Teledyne LeCroy T3PM1100

  • Single Phase Digital Power Meter
  • 4 x Test Leads
  • 3 x Power Cords
  • Quick Start Guide
  • Three-Year Warranty

Ask a question about Teledyne LeCroy T3PM1100 Single Phase Digital Power Meter, 5", 100 kHz

Customer Reviews for the Teledyne LeCroy T3PM1100

Teledyne LeCroy T3PM1100 Offers

Measure the power consumption of products and standby power consumption of low-power devices with this meter. In addition, this power meter provides RS-232C, USB device (virtual COM), and LAN communication interfaces for remote control applications.

Features

  • 5" (127 mm) large TFT LCD display
  • Two numerical display modes along with a waveform display of various parameters
  • Automatic Level-changing feature for integration function
  • External current sensor input terminal
  • Standard interfaces: USB, LAN, RS-232C
  • Clear visibility of your measurement results
  • Choose the best display mode for your measurement requirements
  • Achieve faster measurement results without worrying about power level changes
  • Extends the current measurement capability for various application requirements
  • Remote control of your measurements
  • Reliable product gives peace of mind
  • DC, 0.1 Hz to 100 kHz voltage/current test bandwidth
  • General Mode: Displays two main test items + eight secondary test items
  • Simple mode: Displays the test values of four main test items
  • Waveform display: V (Voltage), I (Current), P (Power)
  • The current/voltage can be measured to a deformed wave with CF of three, and the half-range CF can reach 6 or 6 A
  • Meets the IEC 61000-4-7 harmonics measurement requirements (50/60 Hz)
  • 50th order of harmonic measurement and analysis (value and bar graph)
  • Integration function supports automatic levelchanging
  • Full five-digit measurement
  • Maximum accuracy of 0.1% of reading + 0.05% of range
  • Selectable boot settings (Previous/default)
  • Waveform display up to 10 kHz along with harmonic bar and list table

Various display modes

The results of parameter measurement are displayed in numerical as well as graphical formats. Numerical format offers general and simple mode to display various parameters. The general mode can display 10 measurement parameters (Two main measurements + 8 monitoring measurements), and the simple mode can display four measurement parameters. These displayed parameters can be arbitrarily selected from 25 power ­parameters according to user requirements. The graphical format can display waveforms of voltage, current and power. The horizontal scale can be adjusted from 25 μs/div to 1 s/div (depends on data update rate). Three magnification levels for waveform are also provided for users to select.

In the harmonic measurement, the measurement result of each order of harmonics can be displayed by bar graphs, and a specific order can be specified for observation. The relevant values of each order of harmonics such as voltage, current, power, voltage distortion ratio, current distortion ratio, power distortion ratio, voltage phase angle, current phase angle can be recorded and displayed.

Rich measurement parameters

This digital power meter provides various measurement functions such as voltage, current, frequency, effective power, apparent power, reactive power, power factor, crest factor, total harmonic distortion, and maximum current ratio. This powere meter is also equipped to measure time integral of power or current for the DUT. Users can set a time window to perform instantaneous power integration at specified intervals and then divide value by total time period to obtain the average power of the DUT.

During integration measurement, this power meter supports automatic level changing function according to DUT power level in order to obtain accurate results.

Auxiliary measurement functions

This digital power meter has rich set of auxiliary measurement functions. High voltage measurements can be done using VT rate setting along with an external voltage potential transformer. To measure currents above 20 A a current transformer can be used and the type of CT determines the instrument settings. When a voltage output type CT is used, measurement can be conducted through the external current sensor input terminals EXT1/EXT2.

In addition, this power meter provides four sets of panel settings for storage/recall and memory for storing 10,000 sets of measurement values. The measurement storage can log the measurement results based upon the update rate or a self-defined time interval to facilitate the subsequent analysis. The USB host on the front panel supports screen capture, measurement value storage, and digital power meter firmware update. When a current output type CT is used, the CT can be directly connected to current input terminal on the rear panel and setting the appropriate CT ratio state in the Ratio configuration menu.

Applications

  • Power supplies
  • Transformers
  • Motors
  • Electrical equipment
  • Other equipment with low standby power

Teledyne LeCroy T3PM1100 Specifications

Input
Type Voltage: Floating input through resistive voltage divider
Current: Floating input through shunt
Measuring Range Voltage: 15, 30, 60, 150, 300, and 600 V
Current:
Direct input: 5, 10, 20, 50, 100, and 200 mA/0.5, 1, 2, 5, 10, and 20 A
Sensor input:
EXT 1: 2.5, 5 , and 10 V
EXT 2: 50, 100, 200, and 500 mV/1 and 2 V
Impedance Voltage: input resistance: 2 MΩ
Current:
Direct input range 5 ~ 200 mA: input resistance: 505 mΩ
Direct input range 0.5 ~ 20 A: input resistance: 5 mΩ
Sensor input:
Input range 2.5 ~ 10 V (EXT1): Input resistance: 100 kΩ
Input range 50 mV ~ 2 V (EXT2): Input resistance: 20 kΩ
Continuous Maximum Allowable Input Voltage: Peak value of 1.5 kV or RMS value of 1 kV, whichever is less
Current:
Direct input range 5 ~ 200 mA: Peak value of 30 A or RMS value of 20 A, whichever is less
Direct input range 0.5 ~ 20 A: Peak value of 100 A or RMS value of 30 A, whichever is less
Sensor input: Peak value less than or equal to five times of the rated range
Bandwidth DC, 0.1 Hz ~ 100 kHz
Continuous Maximum Common-Mode Voltage 600 Vrms, CAT II
Filter Line and frequency: Select OFF or ON (cut off frequency of 500 Hz)
A/D Converter Simultaneous conversion voltage and current inputs
Resolution 16 bits
Maximum conversion rate approximately 300 kHz
Voltage and Current Accuracy
Requirements Temperature: 23 ± 5°C
Humidity: 30 ~ 75 % RH
Input waveform: Sine wave crest factor = 3
Common-mode voltage: 0 V
Number of displayed digits: 5 digits
Frequency filter: Turn on to measure voltage or current of 200 Hz or less
Warm-up time: 30 minutes
Update interval: 250 ms
Accuracy DC: ± (0.1 % of reading + 0.2 % of range)
0.1 Hz ≤ f <45 Hz: ± (0.1 % of reading + 0.2 % of range)
45 Hz &le f ≤66 Hz: ± (0.1 % of reading + 0.05 % of range)
66 Hz < f &le1 kHz: ± (0.1 % of reading + 0.2 % of range)
1 kHz < f ≤10 kHz: ± (0.07 *f) % of reading + 0.3 % of range)
10 < f ≤100 kHz: ± (0.5 % of reading + 0.5 % of range) ± [{0.04 x (f-10)} % of reading]
When the Crest Factor is set to 6 or 6 A: Accuracy obtained by doubling the measurement range error for the accuracy when the crest factor is set to 3
Changes caused by data update interval: When the data update interval is 100 ms, and auto, add 0.05 % of reading to the 0.1 Hz to 1 kHz accuracy
Temperature Coefficient Add: ±0.03 % of reading/°C within the range 5 to 18°C or 28 to 40°C
When the Line Filter is Turned ON 45 ~ 66 Hz: Add 0.2 % of reading
<45 Hz: Add 0.5 % ofreading
Accuracy when the Crest Factor is set to 6 or 6 A Accuracy obtained by doubling the measurement range error for the accuracy when the crest factor is set to 3
Accuracy Changes Caused by Data Update Interval When the data update interval is 100 ms, and Auto, add 0.05 % of readingto the 0.1 Hz to 1 kHz accuracy
Influence of Temperature Changes After Zero-Level Compensation or Range Change DC voltage accuracy: Add 0.02 % of range/°C
DC current accuracies:
5/10/20/50/100/ and 200 mA ranges: Add 5 μA/°C
0.5/1/2/5/10/ and 20 A ranges: Add 500 μA/°C
External current sensor input (/EXT 1): Add 1 mV/°C
External current sensor input (/EXT2): Add 50 μV/°C
Active Power Accuracy
Requirements Same as the conditions for voltage and current
Power factor
Accuracy DC: (0.1 % of reading + 0.2 % of range)
0.1 Hz ≤ f <45 Hz: ± (0.3 % of reading + 0.2 % of range)
45 Hz ≤ f <66 Hz: ± (0.1 % of reading + 0.05 % of range)
66 Hz < f ≤1 kHz: ± (0.2 % of reading + 0.2 % of range)
1 kHz < f ≤10 kHz: ± (0.1 % of reading + 0.3 % of range) ± [{0.067 x (f-1)} % of reading]
10 kHz < f ≤100 kHz: ± (0.5 % of reading + 0.5 % of range) ± [{0.09 x (f-10)} % of reading]
When the crest factor is set to 6 or 6 A: Accuracy obtained by doubling the measurement range error for the accuracy when the crest factor is set to 3
f Apparent power S: Voltage accuracy + current accuracy
Reactive power Q: Accuracy of apparent power + (√1.0004 - λ2) - (√1 - λ2) x 100 %
Power factor Λ: ± [(λ-λ/1.0002) + [λcosø-cos{ø+sin-1 (influence from the power factor when λ = 0 %/100)} I ] ±1 digit when voltage and current are at the measurement range rated input
Phase difference Φ: ± [ I ø-cos-1 (λ/1.0002) I + sin-1 (influence from the power factor when λ = 0 % / 100)] ±1 digit when voltage and current are at the measurement range rated input
Changes caused by data update interval: When the data update interval is 100 ms, and Auto, add 0.05 % of reading to the 0.1 Hz to 1 kHz accuracy
Influence of Power Factor When power factor (λ) = 0 (S: apparent power)
±0.1 % of S for 45 Hz ≤ f ≤66 Hz
± {(0.1 + 0.15 x f) % of S} for up to 100 kHz as reference data
f is frequency of input signal in kHz
when 0 < λ < 1 (Φ: phase angle of the voltage and current) (power reading) x [(power reading error %) + (power range %) x (power range/indicated apparent power value) + {tanΦ x (influence when λ = o) %}]
When the Line Filter is Turned ON 45 ~ 66 Hz: Add 0.3 % of reading
<45 Hz: Add 1 % of reading
Temperature Coefficient Same as the temperature coefficient for voltage and current
Frequency Measurement
Measurement Parameter: Voltage and current
Frequency range:
Data update interval: Measurement frequency range
0.1 s: 20 Hz ≤ f ≤100 kHz
0.25 s: 10 Hz ≤ f ≤100 kHz
0.5 s: 5 Hz ≤ f ≤100 kHz
1 s: 2 Hz ≤ f ≤100 kHz
2 s: 1 Hz ≤ f ≤100 kHz
5 s: 0.5 Hz ≤ f ≤100 kHz
10 s: 0.2 Hz ≤ f ≤100 kHz
20 s: 0.1 Hz ≤ f ≤100 kHz
Auto (*): 0.1 Hz ≤ f ≤100 kHz
(*) Lower frequency measurement limit is defined by timeout setting
Timeout: Lower frequency limit
1 s: 2 Hz
5 s: 0.5 Hz
10 s: 0.2 Hz
20 s: 0.1 Hz
Range: Auto switching between six frequencies: 100 mHz, 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, and 100 kHz
Filter Select OFF or ON (cut off frequency of 500 Hz)
Accuracy Requirements: Input signal level should be greater than 30% of the measurement range if the crest factor is set to 3. (60 % or more if the crest factor is set to 6 or 6 A) and frequency filter should be ON when the frequency of the signal is less than 200 Hz
± (0.06 % of reading)
Integration
Mode Selectable manual integration mode, standard integration mode, or repetitive integration mode
Timer Automatically stop integration by setting a timer
Selectable range: 0 hours 0 minutes 0 seconds to 9999 hours 59 minutes 59 seconds
Accuracy ± (Power accuracy (or current accuracy) + 0.1 % of reading), fixed range
Timer Accuracy ±0.02 %
Harmonic Measurement
Measured Item: Voltage, current, power
Method: Zero-cross simultaneous calculation method
Frequency Range 10 Hz to 1.2 kHz
FFT Data Length 1024
4096 (Auto switch when both 50/60 Hz and update rate >0.1 s conditions are met)
Sample Rate, Window Width, and Upper Limit of Analysis Orders Fundamental frequency:

10 to 44 Hz:
Sample rate: f x 1024
Window width: 1
Upper limit of analysis orders: 50

45 to 55 Hz:
Sample rate: f x 512
Window width: 10
Upper limit of analysis orders: 50

54 to 66 Hz:
Sample rate: f x 512
Window width: 12
Upper limit of analysis orders: 50

67 to 150 Hz:
Sample rate: f x 512Window width: 2
Upper limit of analysis orders: 32

150 to 300 Hz:
Sample rate: f x 256
Widnow width: 4
Upper limit of analysis orders: 16

300 to 600 Hz: Sample rate: f x 128
Window width: 8
Upper limit of analysis orders: 8

600 to 1200 Hz:
Sample rate: f x 64
Window width: 16
Upper limit of analysis orders: 4
Accuracy Frequency:

10 Hz ≤ f <45 Hz:
Voltage: 0.15 % of reading + 0.35 % of range
Current: 0.15 % of reading + 0.35 % of range
Power: 0.35 % of reading + 0.5 % of range

45 Hz ≤ f <440 Hz:
Voltage: 0.15 % of reading + 0.35 % of range
Current: 0.15 % of reading + 0.35 % of range
Power: 0.25 % of reading + 0.5 % of range

440 Hz ≤ f <1.2 kHz:
Voltage: 0.2 % of reading + 0.35 % of range
Current: 0.2 % of reading + 0.35 % of range
Power: 0.4 % of reading + 0.5 % of range
General Specifications
Condition Specification:
Temperature: 23°C ± 5°C
Humidity: <80 % RH (non-condensing)

Operation: Temperature 32°F ~ 104°F (0°C ~ 40°C)
30 ~ 40°C, relative humidity <70 % RH (non-condensing)
>40°C, relative humidity <50 % RH (non-condensing)
Indoor use only
Altitude: <2000 meters
Pollution degree 2

Storage: Temperature -40 to 158°F (-40°C ~ 70°C)
Humidity: <90 % RH (non-condensing)
Power Source AC 100 to 240 V, 50 to 60 Hz; consumption maximum 30 VA
Dimensions 10.55 x 4.21 x 14.92", w/t bumpers (268 x 107 x 379 mm, w/t bumpers)
Weight Approximately 6.39 lbs (2.9 kg)
Click here for complete specifications on the Teledyne LeCroy T3PM1100

What's included with the Teledyne LeCroy T3PM1100

  • Single Phase Digital Power Meter
  • 4 x Test Leads
  • 3 x Power Cords
  • Quick Start Guide
  • Three-Year Warranty

Ask a question about Teledyne LeCroy T3PM1100 Single Phase Digital Power Meter, 5", 100 kHz