Work with clear visibility of your measurement results with this reliable meter that features a 5" (127 mm) LCD and an input bandwidth of 0.1 Hz ~ 100 kHz. In addition, this meter offers display waveform (voltage/current/power), the integration measurement function, harmonic measurement, and analysis of each order.
Work with clear visibility of your measurement results with this reliable meter that features a 5" (127 mm) LCD and an input bandwidth of 0.1 Hz ~ 100 kHz. In addition, this meter offers display waveform (voltage/current/power), the integration measurement function, harmonic measurement, and analysis of each order.
Measure the power consumption of products and standby power consumption of low-power devices with this meter. In addition, this power meter provides RS-232C, USB device (virtual COM), and LAN communication interfaces for remote control applications.
Features
Various display modes
The results of parameter measurement are displayed in numerical as well as graphical formats. Numerical format offers general and simple mode to display various parameters. The general mode can display 10 measurement parameters (Two main measurements + 8 monitoring measurements), and the simple mode can display four measurement parameters. These displayed parameters can be arbitrarily selected from 25 power parameters according to user requirements. The graphical format can display waveforms of voltage, current and power. The horizontal scale can be adjusted from 25 μs/div to 1 s/div (depends on data update rate). Three magnification levels for waveform are also provided for users to select.
In the harmonic measurement, the measurement result of each order of harmonics can be displayed by bar graphs, and a specific order can be specified for observation. The relevant values of each order of harmonics such as voltage, current, power, voltage distortion ratio, current distortion ratio, power distortion ratio, voltage phase angle, current phase angle can be recorded and displayed.
Rich measurement parameters
This digital power meter provides various measurement functions such as voltage, current, frequency, effective power, apparent power, reactive power, power factor, crest factor, total harmonic distortion, and maximum current ratio. This powere meter is also equipped to measure time integral of power or current for the DUT. Users can set a time window to perform instantaneous power integration at specified intervals and then divide value by total time period to obtain the average power of the DUT.
During integration measurement, this power meter supports automatic level changing function according to DUT power level in order to obtain accurate results.
Auxiliary measurement functions
This digital power meter has rich set of auxiliary measurement functions. High voltage measurements can be done using VT rate setting along with an external voltage potential transformer. To measure currents above 20 A a current transformer can be used and the type of CT determines the instrument settings. When a voltage output type CT is used, measurement can be conducted through the external current sensor input terminals EXT1/EXT2.
In addition, this power meter provides four sets of panel settings for storage/recall and memory for storing 10,000 sets of measurement values. The measurement storage can log the measurement results based upon the update rate or a self-defined time interval to facilitate the subsequent analysis. The USB host on the front panel supports screen capture, measurement value storage, and digital power meter firmware update.
When a current output type CT is used, the CT can be directly connected to current input terminal on the rear panel and setting the appropriate CT ratio state in the Ratio configuration menu.
Applications
Input | |
Type | Voltage: Floating input through resistive voltage divider Current: Floating input through shunt |
Measuring Range | Voltage: 15, 30, 60, 150, 300, and 600 V Current: Direct input: 5, 10, 20, 50, 100, and 200 mA/0.5, 1, 2, 5, 10, and 20 A Sensor input: EXT 1: 2.5, 5 , and 10 V EXT 2: 50, 100, 200, and 500 mV/1 and 2 V |
Impedance | Voltage: input resistance: 2 MΩ Current: Direct input range 5 ~ 200 mA: input resistance: 505 mΩ Direct input range 0.5 ~ 20 A: input resistance: 5 mΩ Sensor input: Input range 2.5 ~ 10 V (EXT1): Input resistance: 100 kΩ Input range 50 mV ~ 2 V (EXT2): Input resistance: 20 kΩ |
Continuous Maximum Allowable Input | Voltage: Peak value of 1.5 kV or RMS value of 1 kV, whichever is less Current: Direct input range 5 ~ 200 mA: Peak value of 30 A or RMS value of 20 A, whichever is less Direct input range 0.5 ~ 20 A: Peak value of 100 A or RMS value of 30 A, whichever is less Sensor input: Peak value less than or equal to five times of the rated range |
Bandwidth | DC, 0.1 Hz ~ 100 kHz |
Continuous Maximum Common-Mode Voltage | 600 Vrms, CAT II |
Filter | Line and frequency: Select OFF or ON (cut off frequency of 500 Hz) |
A/D Converter | Simultaneous conversion voltage and current inputs Resolution 16 bits Maximum conversion rate approximately 300 kHz |
Voltage and Current Accuracy | |
Requirements | Temperature: 23 ± 5°C Humidity: 30 ~ 75 % RH Input waveform: Sine wave crest factor = 3 Common-mode voltage: 0 V Number of displayed digits: 5 digits Frequency filter: Turn on to measure voltage or current of 200 Hz or less Warm-up time: 30 minutes Update interval: 250 ms |
Accuracy | DC: ± (0.1 % of reading + 0.2 % of range) 0.1 Hz ≤ f <45 Hz: ± (0.1 % of reading + 0.2 % of range) 45 Hz &le f ≤66 Hz: ± (0.1 % of reading + 0.05 % of range) 66 Hz < f &le1 kHz: ± (0.1 % of reading + 0.2 % of range) 1 kHz < f ≤10 kHz: ± (0.07 *f) % of reading + 0.3 % of range) 10 < f ≤100 kHz: ± (0.5 % of reading + 0.5 % of range) ± [{0.04 x (f-10)} % of reading] When the Crest Factor is set to 6 or 6 A: Accuracy obtained by doubling the measurement range error for the accuracy when the crest factor is set to 3 Changes caused by data update interval: When the data update interval is 100 ms, and auto, add 0.05 % of reading to the 0.1 Hz to 1 kHz accuracy |
Temperature Coefficient | Add: ±0.03 % of reading/°C within the range 5 to 18°C or 28 to 40°C |
When the Line Filter is Turned ON | 45 ~ 66 Hz: Add 0.2 % of reading <45 Hz: Add 0.5 % ofreading |
Accuracy when the Crest Factor is set to 6 or 6 A | Accuracy obtained by doubling the measurement range error for the accuracy when the crest factor is set to 3 |
Accuracy Changes Caused by Data Update Interval | When the data update interval is 100 ms, and Auto, add 0.05 % of readingto the 0.1 Hz to 1 kHz accuracy |
Influence of Temperature Changes After Zero-Level Compensation or Range Change | DC voltage accuracy: Add 0.02 % of range/°C DC current accuracies: 5/10/20/50/100/ and 200 mA ranges: Add 5 μA/°C 0.5/1/2/5/10/ and 20 A ranges: Add 500 μA/°C External current sensor input (/EXT 1): Add 1 mV/°C External current sensor input (/EXT2): Add 50 μV/°C |
Active Power Accuracy | |
Requirements | Same as the conditions for voltage and current Power factor |
Accuracy | DC: (0.1 % of reading + 0.2 % of range) 0.1 Hz ≤ f <45 Hz: ± (0.3 % of reading + 0.2 % of range) 45 Hz ≤ f <66 Hz: ± (0.1 % of reading + 0.05 % of range) 66 Hz < f ≤1 kHz: ± (0.2 % of reading + 0.2 % of range) 1 kHz < f ≤10 kHz: ± (0.1 % of reading + 0.3 % of range) ± [{0.067 x (f-1)} % of reading] 10 kHz < f ≤100 kHz: ± (0.5 % of reading + 0.5 % of range) ± [{0.09 x (f-10)} % of reading] When the crest factor is set to 6 or 6 A: Accuracy obtained by doubling the measurement range error for the accuracy when the crest factor is set to 3 f Apparent power S: Voltage accuracy + current accuracy Reactive power Q: Accuracy of apparent power + (√1.0004 - λ2) - (√1 - λ2) x 100 % Power factor Λ: ± [(λ-λ/1.0002) + [λcosø-cos{ø+sin-1 (influence from the power factor when λ = 0 %/100)} I ] ±1 digit when voltage and current are at the measurement range rated input Phase difference Φ: ± [ I ø-cos-1 (λ/1.0002) I + sin-1 (influence from the power factor when λ = 0 % / 100)] ±1 digit when voltage and current are at the measurement range rated input Changes caused by data update interval: When the data update interval is 100 ms, and Auto, add 0.05 % of reading to the 0.1 Hz to 1 kHz accuracy |
Influence of Power Factor | When power factor (λ) = 0 (S: apparent power) ±0.1 % of S for 45 Hz ≤ f ≤66 Hz ± {(0.1 + 0.15 x f) % of S} for up to 100 kHz as reference data f is frequency of input signal in kHz when 0 < λ < 1 (Φ: phase angle of the voltage and current) (power reading) x [(power reading error %) + (power range %) x (power range/indicated apparent power value) + {tanΦ x (influence when λ = o) %}] |
When the Line Filter is Turned ON | 45 ~ 66 Hz: Add 0.3 % of reading <45 Hz: Add 1 % of reading |
Temperature Coefficient | Same as the temperature coefficient for voltage and current |
Frequency Measurement | |
Measurement | Parameter: Voltage and current Frequency range: Data update interval: Measurement frequency range 0.1 s: 20 Hz ≤ f ≤100 kHz 0.25 s: 10 Hz ≤ f ≤100 kHz 0.5 s: 5 Hz ≤ f ≤100 kHz 1 s: 2 Hz ≤ f ≤100 kHz 2 s: 1 Hz ≤ f ≤100 kHz 5 s: 0.5 Hz ≤ f ≤100 kHz 10 s: 0.2 Hz ≤ f ≤100 kHz 20 s: 0.1 Hz ≤ f ≤100 kHz Auto (*): 0.1 Hz ≤ f ≤100 kHz (*) Lower frequency measurement limit is defined by timeout setting Timeout: Lower frequency limit 1 s: 2 Hz 5 s: 0.5 Hz 10 s: 0.2 Hz 20 s: 0.1 Hz Range: Auto switching between six frequencies: 100 mHz, 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, and 100 kHz |
Filter | Select OFF or ON (cut off frequency of 500 Hz) |
Accuracy | Requirements: Input signal level should be greater than 30% of the measurement range if the crest factor is set to 3. (60 % or more if the crest factor is set to 6 or 6 A) and frequency filter should be ON when the frequency of the signal is less than 200 Hz ± (0.06 % of reading) |
Integration | |
Mode | Selectable manual integration mode, standard integration mode, or repetitive integration mode |
Timer | Automatically stop integration by setting a timer Selectable range: 0 hours 0 minutes 0 seconds to 9999 hours 59 minutes 59 seconds |
Accuracy | ± (Power accuracy (or current accuracy) + 0.1 % of reading), fixed range |
Timer Accuracy | ±0.02 % |
Harmonic Measurement | |
Measured | Item: Voltage, current, power Method: Zero-cross simultaneous calculation method |
Frequency Range | 10 Hz to 1.2 kHz |
FFT Data Length | 1024 4096 (Auto switch when both 50/60 Hz and update rate >0.1 s conditions are met) |
Sample Rate, Window Width, and Upper Limit of Analysis Orders | Fundamental frequency: 10 to 44 Hz: Sample rate: f x 1024 Window width: 1 Upper limit of analysis orders: 50 45 to 55 Hz: Sample rate: f x 512 Window width: 10 Upper limit of analysis orders: 50 54 to 66 Hz: Sample rate: f x 512 Window width: 12 Upper limit of analysis orders: 50 67 to 150 Hz: Sample rate: f x 512 Upper limit of analysis orders: 32 150 to 300 Hz: Sample rate: f x 256 Widnow width: 4 Upper limit of analysis orders: 16 300 to 600 Hz: Sample rate: f x 128 Window width: 8 Upper limit of analysis orders: 8 600 to 1200 Hz: Sample rate: f x 64 Window width: 16 Upper limit of analysis orders: 4 |
Accuracy | Frequency: 10 Hz ≤ f <45 Hz: Voltage: 0.15 % of reading + 0.35 % of range Current: 0.15 % of reading + 0.35 % of range Power: 0.35 % of reading + 0.5 % of range 45 Hz ≤ f <440 Hz: Voltage: 0.15 % of reading + 0.35 % of range Current: 0.15 % of reading + 0.35 % of range Power: 0.25 % of reading + 0.5 % of range 440 Hz ≤ f <1.2 kHz: Voltage: 0.2 % of reading + 0.35 % of range Current: 0.2 % of reading + 0.35 % of range Power: 0.4 % of reading + 0.5 % of range |
General Specifications | |
Condition | Specification: Temperature: 23°C ± 5°C Humidity: <80 % RH (non-condensing) Operation: Temperature 32°F ~ 104°F (0°C ~ 40°C) 30 ~ 40°C, relative humidity <70 % RH (non-condensing) >40°C, relative humidity <50 % RH (non-condensing) Indoor use only Altitude: <2000 meters Pollution degree 2 Storage: Temperature -40 to 158°F (-40°C ~ 70°C) Humidity: <90 % RH (non-condensing) |
Power Source | AC 100 to 240 V, 50 to 60 Hz; consumption maximum 30 VA |
Dimensions | 10.55 x 4.21 x 14.92", w/t bumpers (268 x 107 x 379 mm, w/t bumpers) |
Weight | Approximately 6.39 lbs (2.9 kg) |
Input | |
Type | Voltage: Floating input through resistive voltage divider Current: Floating input through shunt |
Measuring Range | Voltage: 15, 30, 60, 150, 300, and 600 V Current: Direct input: 5, 10, 20, 50, 100, and 200 mA/0.5, 1, 2, 5, 10, and 20 A Sensor input: EXT 1: 2.5, 5 , and 10 V EXT 2: 50, 100, 200, and 500 mV/1 and 2 V |
Impedance | Voltage: input resistance: 2 MΩ Current: Direct input range 5 ~ 200 mA: input resistance: 505 mΩ Direct input range 0.5 ~ 20 A: input resistance: 5 mΩ Sensor input: Input range 2.5 ~ 10 V (EXT1): Input resistance: 100 kΩ Input range 50 mV ~ 2 V (EXT2): Input resistance: 20 kΩ |
Continuous Maximum Allowable Input | Voltage: Peak value of 1.5 kV or RMS value of 1 kV, whichever is less Current: Direct input range 5 ~ 200 mA: Peak value of 30 A or RMS value of 20 A, whichever is less Direct input range 0.5 ~ 20 A: Peak value of 100 A or RMS value of 30 A, whichever is less Sensor input: Peak value less than or equal to five times of the rated range |
Bandwidth | DC, 0.1 Hz ~ 100 kHz |
Continuous Maximum Common-Mode Voltage | 600 Vrms, CAT II |
Filter | Line and frequency: Select OFF or ON (cut off frequency of 500 Hz) |
A/D Converter | Simultaneous conversion voltage and current inputs Resolution 16 bits Maximum conversion rate approximately 300 kHz |
Voltage and Current Accuracy | |
Requirements | Temperature: 23 ± 5°C Humidity: 30 ~ 75 % RH Input waveform: Sine wave crest factor = 3 Common-mode voltage: 0 V Number of displayed digits: 5 digits Frequency filter: Turn on to measure voltage or current of 200 Hz or less Warm-up time: 30 minutes Update interval: 250 ms |
Accuracy | DC: ± (0.1 % of reading + 0.2 % of range) 0.1 Hz ≤ f <45 Hz: ± (0.1 % of reading + 0.2 % of range) 45 Hz &le f ≤66 Hz: ± (0.1 % of reading + 0.05 % of range) 66 Hz < f &le1 kHz: ± (0.1 % of reading + 0.2 % of range) 1 kHz < f ≤10 kHz: ± (0.07 *f) % of reading + 0.3 % of range) 10 < f ≤100 kHz: ± (0.5 % of reading + 0.5 % of range) ± [{0.04 x (f-10)} % of reading] When the Crest Factor is set to 6 or 6 A: Accuracy obtained by doubling the measurement range error for the accuracy when the crest factor is set to 3 Changes caused by data update interval: When the data update interval is 100 ms, and auto, add 0.05 % of reading to the 0.1 Hz to 1 kHz accuracy |
Temperature Coefficient | Add: ±0.03 % of reading/°C within the range 5 to 18°C or 28 to 40°C |
When the Line Filter is Turned ON | 45 ~ 66 Hz: Add 0.2 % of reading <45 Hz: Add 0.5 % ofreading |
Accuracy when the Crest Factor is set to 6 or 6 A | Accuracy obtained by doubling the measurement range error for the accuracy when the crest factor is set to 3 |
Accuracy Changes Caused by Data Update Interval | When the data update interval is 100 ms, and Auto, add 0.05 % of readingto the 0.1 Hz to 1 kHz accuracy |
Influence of Temperature Changes After Zero-Level Compensation or Range Change | DC voltage accuracy: Add 0.02 % of range/°C DC current accuracies: 5/10/20/50/100/ and 200 mA ranges: Add 5 μA/°C 0.5/1/2/5/10/ and 20 A ranges: Add 500 μA/°C External current sensor input (/EXT 1): Add 1 mV/°C External current sensor input (/EXT2): Add 50 μV/°C |
Active Power Accuracy | |
Requirements | Same as the conditions for voltage and current Power factor |
Accuracy | DC: (0.1 % of reading + 0.2 % of range) 0.1 Hz ≤ f <45 Hz: ± (0.3 % of reading + 0.2 % of range) 45 Hz ≤ f <66 Hz: ± (0.1 % of reading + 0.05 % of range) 66 Hz < f ≤1 kHz: ± (0.2 % of reading + 0.2 % of range) 1 kHz < f ≤10 kHz: ± (0.1 % of reading + 0.3 % of range) ± [{0.067 x (f-1)} % of reading] 10 kHz < f ≤100 kHz: ± (0.5 % of reading + 0.5 % of range) ± [{0.09 x (f-10)} % of reading] When the crest factor is set to 6 or 6 A: Accuracy obtained by doubling the measurement range error for the accuracy when the crest factor is set to 3 f Apparent power S: Voltage accuracy + current accuracy Reactive power Q: Accuracy of apparent power + (√1.0004 - λ2) - (√1 - λ2) x 100 % Power factor Λ: ± [(λ-λ/1.0002) + [λcosø-cos{ø+sin-1 (influence from the power factor when λ = 0 %/100)} I ] ±1 digit when voltage and current are at the measurement range rated input Phase difference Φ: ± [ I ø-cos-1 (λ/1.0002) I + sin-1 (influence from the power factor when λ = 0 % / 100)] ±1 digit when voltage and current are at the measurement range rated input Changes caused by data update interval: When the data update interval is 100 ms, and Auto, add 0.05 % of reading to the 0.1 Hz to 1 kHz accuracy |
Influence of Power Factor | When power factor (λ) = 0 (S: apparent power) ±0.1 % of S for 45 Hz ≤ f ≤66 Hz ± {(0.1 + 0.15 x f) % of S} for up to 100 kHz as reference data f is frequency of input signal in kHz when 0 < λ < 1 (Φ: phase angle of the voltage and current) (power reading) x [(power reading error %) + (power range %) x (power range/indicated apparent power value) + {tanΦ x (influence when λ = o) %}] |
When the Line Filter is Turned ON | 45 ~ 66 Hz: Add 0.3 % of reading <45 Hz: Add 1 % of reading |
Temperature Coefficient | Same as the temperature coefficient for voltage and current |
Frequency Measurement | |
Measurement | Parameter: Voltage and current Frequency range: Data update interval: Measurement frequency range 0.1 s: 20 Hz ≤ f ≤100 kHz 0.25 s: 10 Hz ≤ f ≤100 kHz 0.5 s: 5 Hz ≤ f ≤100 kHz 1 s: 2 Hz ≤ f ≤100 kHz 2 s: 1 Hz ≤ f ≤100 kHz 5 s: 0.5 Hz ≤ f ≤100 kHz 10 s: 0.2 Hz ≤ f ≤100 kHz 20 s: 0.1 Hz ≤ f ≤100 kHz Auto (*): 0.1 Hz ≤ f ≤100 kHz (*) Lower frequency measurement limit is defined by timeout setting Timeout: Lower frequency limit 1 s: 2 Hz 5 s: 0.5 Hz 10 s: 0.2 Hz 20 s: 0.1 Hz Range: Auto switching between six frequencies: 100 mHz, 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, and 100 kHz |
Filter | Select OFF or ON (cut off frequency of 500 Hz) |
Accuracy | Requirements: Input signal level should be greater than 30% of the measurement range if the crest factor is set to 3. (60 % or more if the crest factor is set to 6 or 6 A) and frequency filter should be ON when the frequency of the signal is less than 200 Hz ± (0.06 % of reading) |
Integration | |
Mode | Selectable manual integration mode, standard integration mode, or repetitive integration mode |
Timer | Automatically stop integration by setting a timer Selectable range: 0 hours 0 minutes 0 seconds to 9999 hours 59 minutes 59 seconds |
Accuracy | ± (Power accuracy (or current accuracy) + 0.1 % of reading), fixed range |
Timer Accuracy | ±0.02 % |
Harmonic Measurement | |
Measured | Item: Voltage, current, power Method: Zero-cross simultaneous calculation method |
Frequency Range | 10 Hz to 1.2 kHz |
FFT Data Length | 1024 4096 (Auto switch when both 50/60 Hz and update rate >0.1 s conditions are met) |
Sample Rate, Window Width, and Upper Limit of Analysis Orders | Fundamental frequency: 10 to 44 Hz: Sample rate: f x 1024 Window width: 1 Upper limit of analysis orders: 50 45 to 55 Hz: Sample rate: f x 512 Window width: 10 Upper limit of analysis orders: 50 54 to 66 Hz: Sample rate: f x 512 Window width: 12 Upper limit of analysis orders: 50 67 to 150 Hz: Sample rate: f x 512 Upper limit of analysis orders: 32 150 to 300 Hz: Sample rate: f x 256 Widnow width: 4 Upper limit of analysis orders: 16 300 to 600 Hz: Sample rate: f x 128 Window width: 8 Upper limit of analysis orders: 8 600 to 1200 Hz: Sample rate: f x 64 Window width: 16 Upper limit of analysis orders: 4 |
Accuracy | Frequency: 10 Hz ≤ f <45 Hz: Voltage: 0.15 % of reading + 0.35 % of range Current: 0.15 % of reading + 0.35 % of range Power: 0.35 % of reading + 0.5 % of range 45 Hz ≤ f <440 Hz: Voltage: 0.15 % of reading + 0.35 % of range Current: 0.15 % of reading + 0.35 % of range Power: 0.25 % of reading + 0.5 % of range 440 Hz ≤ f <1.2 kHz: Voltage: 0.2 % of reading + 0.35 % of range Current: 0.2 % of reading + 0.35 % of range Power: 0.4 % of reading + 0.5 % of range |
General Specifications | |
Condition | Specification: Temperature: 23°C ± 5°C Humidity: <80 % RH (non-condensing) Operation: Temperature 32°F ~ 104°F (0°C ~ 40°C) 30 ~ 40°C, relative humidity <70 % RH (non-condensing) >40°C, relative humidity <50 % RH (non-condensing) Indoor use only Altitude: <2000 meters Pollution degree 2 Storage: Temperature -40 to 158°F (-40°C ~ 70°C) Humidity: <90 % RH (non-condensing) |
Power Source | AC 100 to 240 V, 50 to 60 Hz; consumption maximum 30 VA |
Dimensions | 10.55 x 4.21 x 14.92", w/t bumpers (268 x 107 x 379 mm, w/t bumpers) |
Weight | Approximately 6.39 lbs (2.9 kg) |