TPI DC711 Flue Gas Analyzer

Model: DC711

TPI DC711 Flue Gas Analyzer

Model: DC711

Crafted to cater to the demands of the most active Gas Heating Engineer and Installer.

Crafted to cater to the demands of the most active Gas Heating Engineer and Installer.

Sale Price $850.73 USD
Regular Price $995.00 USD
Availability 2 to 3 Weeks
Quantity

TPI DC711 Offers

Features

  • Easy to Use, Durable & Affordable!
  • Domestic or Commercial
  • Upgradeable to include NOx sensor
  • Multiple Fuel Options
  • Hold, Save, Print & Send
  • Clear, Easy to Read Screen
  • Easy to Navigate Menu System
  • Pressure & Tightness Test feature
  • Differential Temperature for Flow & Return or Radiator Balancing

TPI DC711 Specifications

Operating Temperature Range 14°F to +122°F (-10°C to +50°C)
Battery / Battery Life Li-ion 3.7V / > 6 Hours
Charger Input USB “C” type
Fuels Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
Pressure Ranges mbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O
Display Backlit Graphic LCD
Data Storage 100 sets of readings (30 sets for CO Build Up), multiple pages
Time and Date 24 Hour Real Time Clock
Dimensions 7.28” (185mm) x 4.92” (125mm) x 2.56” (65mm)
Weight 1.83lbs (830g)
Conforms to EN50379 : Parts 1-3
Construction Pistol Grip with Stainless Steel Shaft
Hose Length 8.2’ (2500mm)
Insertion Length 7.9” (200mm)
‘K’ Type Thermocouple Accuracy +/- 0.3% of fullscale, +/- 2°F (1°C)
Maximum Temperature 1472°F (800°C)
Oxygen Range 0-25%
Carbon Monoxide (low) Range 0-10,000 ppm
Carbon Monoxide (high)* Range 0-100,000 ppm
Nitric Oxide * Range 0-5000ppm
Carbon Dioxide Range 0-25%
CO/CO2 Ratio Range 0-0.999
Combustion Efficiency Range 0-100%
Oxygen Resolution Resolution 0.001
Carbon Monoxide (low) Resolution Resolution 1 ppm
Carbon Monoxide (high)* Resolution Resolution 1.0E-5
Nitric Oxide * Resolution 1 ppm
Carbon Dioxide Resolution 0.001
CO/CO2 Ratio Resolution 0.001
Combustion Efficiency Resolution 0.001
Oxygen Accuracy +/- 0.3%
Carbon Monoxide (low) Accuracy (<100ppm) +/- 5 ppm | (>=100ppm) +/- 5%
Carbon Monoxide (high)* Accuracy >10,000ppm: +/- 10%
Nitric Oxide * Accuracy +/- 5ppm (<100ppm) | +/- 5% (<1000ppm) | +/- 10% (>1000ppm)
Carbon Dioxide Accuracy Calculated
CO/CO2 Ratio Accuracy Calculated
Combustion Efficiency Accuracy Calculated

What's included with the TPI DC711

  • TPI DC711 Flue Gas Analyzer

Ask a question about TPI DC711 Flue Gas Analyzer

Customer Reviews for the TPI DC711

TPI DC711 Offers

Features

  • Easy to Use, Durable & Affordable!
  • Domestic or Commercial
  • Upgradeable to include NOx sensor
  • Multiple Fuel Options
  • Hold, Save, Print & Send
  • Clear, Easy to Read Screen
  • Easy to Navigate Menu System
  • Pressure & Tightness Test feature
  • Differential Temperature for Flow & Return or Radiator Balancing

TPI DC711 Specifications

Operating Temperature Range 14°F to +122°F (-10°C to +50°C)
Battery / Battery Life Li-ion 3.7V / > 6 Hours
Charger Input USB “C” type
Fuels Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal, Anthracite Coal, Coke, Butane, Wood, Bagasse
Pressure Ranges mbar, psi, inH2O, mmH2O, kPa, hPa, inHg, mmHg, mH2O
Display Backlit Graphic LCD
Data Storage 100 sets of readings (30 sets for CO Build Up), multiple pages
Time and Date 24 Hour Real Time Clock
Dimensions 7.28” (185mm) x 4.92” (125mm) x 2.56” (65mm)
Weight 1.83lbs (830g)
Conforms to EN50379 : Parts 1-3
Construction Pistol Grip with Stainless Steel Shaft
Hose Length 8.2’ (2500mm)
Insertion Length 7.9” (200mm)
‘K’ Type Thermocouple Accuracy +/- 0.3% of fullscale, +/- 2°F (1°C)
Maximum Temperature 1472°F (800°C)
Oxygen Range 0-25%
Carbon Monoxide (low) Range 0-10,000 ppm
Carbon Monoxide (high)* Range 0-100,000 ppm
Nitric Oxide * Range 0-5000ppm
Carbon Dioxide Range 0-25%
CO/CO2 Ratio Range 0-0.999
Combustion Efficiency Range 0-100%
Oxygen Resolution Resolution 0.001
Carbon Monoxide (low) Resolution Resolution 1 ppm
Carbon Monoxide (high)* Resolution Resolution 1.0E-5
Nitric Oxide * Resolution 1 ppm
Carbon Dioxide Resolution 0.001
CO/CO2 Ratio Resolution 0.001
Combustion Efficiency Resolution 0.001
Oxygen Accuracy +/- 0.3%
Carbon Monoxide (low) Accuracy (<100ppm) +/- 5 ppm | (>=100ppm) +/- 5%
Carbon Monoxide (high)* Accuracy >10,000ppm: +/- 10%
Nitric Oxide * Accuracy +/- 5ppm (<100ppm) | +/- 5% (<1000ppm) | +/- 10% (>1000ppm)
Carbon Dioxide Accuracy Calculated
CO/CO2 Ratio Accuracy Calculated
Combustion Efficiency Accuracy Calculated

What's included with the TPI DC711