Rental – TSI/Alnor 9545-A VelociCalc Air Velocity Meter

Model: 9545-A-RENTAL

Rental – TSI/Alnor 9545-A VelociCalc Air Velocity Meter

Model: 9545-A-RENTAL

This meter measures and data logs several ventilation parameters. Measures velocity, temperature, relative humidity, flow, wet bulb and dew point temperature.

This meter measures and data logs several ventilation parameters. Measures velocity, temperature, relative humidity, flow, wet bulb and dew point temperature.

Duration   day(s)
Your Price
33.00 USD
Quantity

TSI/Alnor 9545-A-RENTAL Offers

This meter simultaneously measures and data logs several ventilation parameters using a single probe with multiple sensors. Ideal for optimizing HVAC/R system performance, commissioning, plant maintenance, critical environment certification and duct traverses. It also features an articulated probe.

Features

  • Simple to operate
  • Accurate air velocity measurement
  • Easy to read display
  • Simultaneously measure temperature and velocity
  • Displays up to three measurements simultaneously
  • Calculates volumetric flow and actual/standard velocity
  • Data log 12,700+ samples and 100 test IDs

Applications

  • HVAC/R system performance
  • Commissioning
  • Plant maintenance
  • Critical environment certification
  • Duct traverses

TSI/Alnor 9545-A-RENTAL Specifications

Velocity
Range 0 to 6000 ft/min (0 to 30 m/s)
Accuracy ±3% of reading or ±3 ft/min (±0.015 m/s), whichever is greater
Resolution 1 ft/min (0.01 m/s)
Duct Size
Dimensions 1 to 250" in increments of 0.1" (1 to 635 cm in increments of 0.1 cm)
Volumetric Flow Rate
Range Actual range is a function of velocity and duct size
Temperature
Range 14 to 140°F (-10 to 60°C)
Accuracy ±0.5°F (±0.3°C)
Resolution 0.1°F (0.1°C)
Relative Humidity
Range 5 to 95% RH
Accuracy ±3% RH
Resolution 0.1% RH
General Specifications
Temperature Range Operating: Electronics - 40 to 113°F (5 to 45°C); Probe - 14 to 140°F (-10 to 60°C)
Storage: -4 to 140°F (-20 to 60°C)
Data Storage Capabilities 12,700+ samples and 100 test IDs
Logging Interval 1 second to 1 hour
Time Constant User selectable
Power Supply 4 x AA-size batteries or AC adapter
Dimensions Meter: 3.3 x 7 x 1.8" (8.4 x 17.8 x 4.4 cm)
Articulating probe: 7.8" (19.7 cm) in length; Articulating knuckle - Ø0.38" (9.5 mm)
Weight 0.6 lbs (0.27 kg) with batteries
Click here for complete specifications on the TSI/Alnor 9545-A-RENTAL

What's included with the TSI/Alnor 9545-A-RENTAL

  • Air Velocity Meter
  • Calibration Certificate
  • Articulated Probe
  • 4 x Alkaline Batteries
  • USB Cable and LogDat2™ Downloading Software
  • Operation and Service Manual

Ask a question about Rental – TSI/Alnor 9545-A VelociCalc Air Velocity Meter

Customer Reviews for the TSI/Alnor 9545-A-RENTAL

TSI/Alnor 9545-A-RENTAL Offers

This meter simultaneously measures and data logs several ventilation parameters using a single probe with multiple sensors. Ideal for optimizing HVAC/R system performance, commissioning, plant maintenance, critical environment certification and duct traverses. It also features an articulated probe.

Features

  • Simple to operate
  • Accurate air velocity measurement
  • Easy to read display
  • Simultaneously measure temperature and velocity
  • Displays up to three measurements simultaneously
  • Calculates volumetric flow and actual/standard velocity
  • Data log 12,700+ samples and 100 test IDs

Applications

  • HVAC/R system performance
  • Commissioning
  • Plant maintenance
  • Critical environment certification
  • Duct traverses

TSI/Alnor 9545-A-RENTAL Specifications

Velocity
Range 0 to 6000 ft/min (0 to 30 m/s)
Accuracy ±3% of reading or ±3 ft/min (±0.015 m/s), whichever is greater
Resolution 1 ft/min (0.01 m/s)
Duct Size
Dimensions 1 to 250" in increments of 0.1" (1 to 635 cm in increments of 0.1 cm)
Volumetric Flow Rate
Range Actual range is a function of velocity and duct size
Temperature
Range 14 to 140°F (-10 to 60°C)
Accuracy ±0.5°F (±0.3°C)
Resolution 0.1°F (0.1°C)
Relative Humidity
Range 5 to 95% RH
Accuracy ±3% RH
Resolution 0.1% RH
General Specifications
Temperature Range Operating: Electronics - 40 to 113°F (5 to 45°C); Probe - 14 to 140°F (-10 to 60°C)
Storage: -4 to 140°F (-20 to 60°C)
Data Storage Capabilities 12,700+ samples and 100 test IDs
Logging Interval 1 second to 1 hour
Time Constant User selectable
Power Supply 4 x AA-size batteries or AC adapter
Dimensions Meter: 3.3 x 7 x 1.8" (8.4 x 17.8 x 4.4 cm)
Articulating probe: 7.8" (19.7 cm) in length; Articulating knuckle - Ø0.38" (9.5 mm)
Weight 0.6 lbs (0.27 kg) with batteries
Click here for complete specifications on the TSI/Alnor 9545-A-RENTAL

What's included with the TSI/Alnor 9545-A-RENTAL

  • Air Velocity Meter
  • Calibration Certificate
  • Articulated Probe
  • 4 x Alkaline Batteries
  • USB Cable and LogDat2™ Downloading Software
  • Operation and Service Manual

Ask a question about Rental – TSI/Alnor 9545-A VelociCalc Air Velocity Meter