Veris CWLSXX Deluxe Wall CO2 Sensor

Model: CWLSXX

Veris CWLSXX Deluxe Wall CO2 Sensor

Model: CWLSXX

The deluxe wall The deluxe wall CO2 sensor maximizes energy savings while ensuring optimal ventilation and allows ventilation systems to be controlled by the amount of CO2 present in a space and also detects fluctuations in CO2 levels.

The deluxe wall The deluxe wall CO2 sensor maximizes energy savings while ensuring optimal ventilation and allows ventilation systems to be controlled by the amount of CO2 present in a space and also detects fluctuations in CO2 levels.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Veris CWLSHX Deluxe Wall CO<sub>2</sub> Sensor, 2% humidity-

Veris CWLSHX Deluxe Wall CO2 Sensor, 2% humidity

Model: CWLSHX

The deluxe wall CO2 sensor maximizes energy savings while ensuring optimal ventilation and allows ventilation systems to be controlled by the amount of CO2 present in a space.


Not what you're looking for? Let’s do a search and help you find what you need.


Veris CWLSXX Offers

The deluxe wall CO₂ sensor maximizes energy savings while ensuring optimal ventilation and allows ventilation systems to be controlled by the amount of CO₂ present in a space and also detects fluctuations in CO₂ levels.

Features

  • Non-dispersive infrared technology repeatable to ±20 ppm ±1% of measured value
  • Innovative self-calibration algorithm easy to maintain
  • 5-year calibration interval (recommended)
  • Field-selectable outputs for operation flexibility
  • Integrated transducer and probe eliminates the need to install a separate pick-up tube
  • Snap-on faceplate; no screws required, making installation and service a snap
  • Adjustable duct probe simplify installation and airflow monitoring
  • CO₂, humidity and temperature sensing all in 1 compact device, so fewer units to buy and install

Applications

  • Controlling Ventilation in Response to Occupancy
  • Facilitating Compliance with ASHRAE 62.1-2004 Standard for Air Quality
  • Office Buildings, Conference Rooms, Schools, Retail Stores, etc

Veris CWLSXX Specifications

Input Power Class 2; 20 to 30 VDC/24 AC 50/60 Hz; 100 mA max
Analog Output 4 to 20 mA (clipped and capped)/0 to 5 VDC/0 to 10 VDC (selectable)
Operating Temperature Range (CWL) No humidity option: 32 to 122°F (0 to 50°C); with humidity option: 50 to 95°F (10 to 35°C)
Operating Humidity Range 0 to 95% RH non-condensing
Housing Material High-impact ABS plastic
Terminal Block Torque: CWL 0.22 N-m (2 in-lbf) max
Terminal Block Wire Size: CWL 30 to 18 AWG (0.08 to 0.5 mm²)
Sensor Type Non-dispersive infrared, diffusion sampling
Output Range 0 to 2,000/5,000 ppm (programmable)
Accuracy ±30 ppm ±2% of measured value
Repeatability ±20 ppm ±1% of measured value
Response Time <60 seconds for 90% step change
HS Sensor Fully replaceable, digitally profiled thin-film capacitive (32-bit mathematics) U.S. Patent 5,844,138
RH Accuracy ±2% from 10 to 80% RH at 77°F (25°C); NIST-traceable multi-point calibration
Hysteresis 1.5% typical
Stability ±1% at 68°F (20°C) annually for 2 years
RH Output Range 0 to 100% RH
Temperature Coefficient ±0.1% RH/°C above or below 77°F (25°C) (typical)
Temperature Sensor Type Solid-state, integrated circuit
Temperature Accuracy ±1°F (±0.5°C) typical
Temperature Resolution 0.2°F (0.1°C)
Temperature Output Range 50 to 95°F (10 to 35°C)
1 Form C (SPDT) 1 A at 30 VDC, resistive; 30 W max (on wall models, relay is only available in units without the setpoint slider option)
Warranty 3 years limited
Click here for complete specifications on the Veris CWLSXX

What's included with the Veris CWLSXX

  • Veris CWLSXX Deluxe Wall CO2 Sensor

Ask a question about Veris CWLSXX Deluxe Wall CO2 Sensor

Customer Reviews for the Veris CWLSXX

Veris CWLSXX Offers

The deluxe wall CO₂ sensor maximizes energy savings while ensuring optimal ventilation and allows ventilation systems to be controlled by the amount of CO₂ present in a space and also detects fluctuations in CO₂ levels.

Features

  • Non-dispersive infrared technology repeatable to ±20 ppm ±1% of measured value
  • Innovative self-calibration algorithm easy to maintain
  • 5-year calibration interval (recommended)
  • Field-selectable outputs for operation flexibility
  • Integrated transducer and probe eliminates the need to install a separate pick-up tube
  • Snap-on faceplate; no screws required, making installation and service a snap
  • Adjustable duct probe simplify installation and airflow monitoring
  • CO₂, humidity and temperature sensing all in 1 compact device, so fewer units to buy and install

Applications

  • Controlling Ventilation in Response to Occupancy
  • Facilitating Compliance with ASHRAE 62.1-2004 Standard for Air Quality
  • Office Buildings, Conference Rooms, Schools, Retail Stores, etc

Veris CWLSXX Specifications

Input Power Class 2; 20 to 30 VDC/24 AC 50/60 Hz; 100 mA max
Analog Output 4 to 20 mA (clipped and capped)/0 to 5 VDC/0 to 10 VDC (selectable)
Operating Temperature Range (CWL) No humidity option: 32 to 122°F (0 to 50°C); with humidity option: 50 to 95°F (10 to 35°C)
Operating Humidity Range 0 to 95% RH non-condensing
Housing Material High-impact ABS plastic
Terminal Block Torque: CWL 0.22 N-m (2 in-lbf) max
Terminal Block Wire Size: CWL 30 to 18 AWG (0.08 to 0.5 mm²)
Sensor Type Non-dispersive infrared, diffusion sampling
Output Range 0 to 2,000/5,000 ppm (programmable)
Accuracy ±30 ppm ±2% of measured value
Repeatability ±20 ppm ±1% of measured value
Response Time <60 seconds for 90% step change
HS Sensor Fully replaceable, digitally profiled thin-film capacitive (32-bit mathematics) U.S. Patent 5,844,138
RH Accuracy ±2% from 10 to 80% RH at 77°F (25°C); NIST-traceable multi-point calibration
Hysteresis 1.5% typical
Stability ±1% at 68°F (20°C) annually for 2 years
RH Output Range 0 to 100% RH
Temperature Coefficient ±0.1% RH/°C above or below 77°F (25°C) (typical)
Temperature Sensor Type Solid-state, integrated circuit
Temperature Accuracy ±1°F (±0.5°C) typical
Temperature Resolution 0.2°F (0.1°C)
Temperature Output Range 50 to 95°F (10 to 35°C)
1 Form C (SPDT) 1 A at 30 VDC, resistive; 30 W max (on wall models, relay is only available in units without the setpoint slider option)
Warranty 3 years limited
Click here for complete specifications on the Veris CWLSXX

What's included with the Veris CWLSXX

  • Veris CWLSXX Deluxe Wall CO2 Sensor

Ask a question about Veris CWLSXX Deluxe Wall CO2 Sensor

Customer Reviews for the Veris CWLSXX

More Veris Products

Calibration Lab