Watlow DIN-A-MITE A Solid State Power Controller, 24 to 48 V AC, 100 to 120 V AC input

Model: DA10-02K2-0000

Watlow DIN-A-MITE A Solid State Power Controller, 24 to 48 V AC, 100 to 120 V AC input

Model: DA10-02K2-0000

Compact and performance-packed, this power controller provides an economical and versatile solid state option for controlling electric heat. In addition, it is 200KA SCCR with proper fusing to minimize damage in the event of a short circuit and features a 24 to 48 V AC line/load voltage and a 100 to 120 V AC control input.

Compact and performance-packed, this power controller provides an economical and versatile solid state option for controlling electric heat. In addition, it is 200KA SCCR with proper fusing to minimize damage in the event of a short circuit and features a 24 to 48 V AC line/load voltage and a 100 to 120 V AC control input.

Regular Price $213.00 USD
Availability 2 to 3 Weeks
Quantity

Watlow DA10-02K2-0000 Offers

Features

  • 200KA SCCR with proper fusing minimizes damage in the event of a short circuit
  • DIN-rail and panel mounting provides versatility and quick, low-cost installation
  • Compact size reduces panel space and cost
  • Touch-safe terminals increases safety for installer and user
  • Mercury free assures environmental safety
  • Faster switching with solid state saves energy and extends heater life
  • UL® 508 listed, C-UL®, RoHS 2 and CE with filter meets applications requiring agency approval, and reduces end product documentation cost
  • Back-to-back SCR design ensures a rugged design

Applications

  • Controlling electric heat
  • Current switching

Watlow DA10-02K2-0000 Specifications

Operator Interface Control input
Input indication LED
Amperage Single-phase, see the output rating curve
Maximum I2t for fusing: 4000 A2 sec
Latching current: 400 mA maximum
Holding current: 200 mA maximum
Power dissipation is 1.2 W/A switched
200KA SCCR, Type 1 and 2 approved with the recommended fusing
Line Voltage 24 to 48 V AC
Off-state leakage: 1 mA at 77°F (25°C) maximum
50/60 Hz independent
Control Mode, Zero Cross VAC input, contactor output
To increase service life, the cycle time should be less than three seconds
Control Input AC contactor: 120 V AC +10/-25% at 25 mA maximum
Terminals Control input: Compression: Will accept 24 to 16 AWG (0.2 to 1.5 mm2) wire
Line and load: Compression: Will accept 18 to 8 AWG (0.8 to 8.4 mm2) wire
Operating Environment -4 to 176°F (-20 to 80°C); see the output rating curve chart for your application
0 to 90% RH (relative humidity), non-condensing
Insulation tested to 9842.52' (3000 m)
Suitable for "Pollution degree 2"
Agency Approvals CE with proper filter:
204/108/EC Electromagnetic Compatibility Directive
EN 61326-1: Industrial Immunity Class A Emissions
2006/95/EC Low Voltage Directive
EN 50178 Safety Requirements
Installation category III, pollution degree 2

UL® 508 listed and C-UL® File E73741
2011/65/EU RoHS 2
Mounting Options include DIN-rail or standard back panel mounting
DIN EN 50022, 1.4 x 0.3" (35 x 7.5 mm)
Mount cooling fins vertically
Dimensions 3.7 x 2 x 3.9" (94 x 50 x 98 mm)
Weight 0.71 lbs (0.32 kg)
Click here for complete specifications on the Watlow DA10-02K2-0000

What's included with the Watlow DA10-02K2-0000

  • Power Controller
  • Three-Year Warranty

Ask a question about Watlow DIN-A-MITE A Solid State Power Controller, 24 to 48 V AC, 100 to 120 V AC input

Customer Reviews for the Watlow DA10-02K2-0000

Watlow DA10-02K2-0000 Offers

Features

  • 200KA SCCR with proper fusing minimizes damage in the event of a short circuit
  • DIN-rail and panel mounting provides versatility and quick, low-cost installation
  • Compact size reduces panel space and cost
  • Touch-safe terminals increases safety for installer and user
  • Mercury free assures environmental safety
  • Faster switching with solid state saves energy and extends heater life
  • UL® 508 listed, C-UL®, RoHS 2 and CE with filter meets applications requiring agency approval, and reduces end product documentation cost
  • Back-to-back SCR design ensures a rugged design

Applications

  • Controlling electric heat
  • Current switching

Watlow DA10-02K2-0000 Specifications

Operator Interface Control input
Input indication LED
Amperage Single-phase, see the output rating curve
Maximum I2t for fusing: 4000 A2 sec
Latching current: 400 mA maximum
Holding current: 200 mA maximum
Power dissipation is 1.2 W/A switched
200KA SCCR, Type 1 and 2 approved with the recommended fusing
Line Voltage 24 to 48 V AC
Off-state leakage: 1 mA at 77°F (25°C) maximum
50/60 Hz independent
Control Mode, Zero Cross VAC input, contactor output
To increase service life, the cycle time should be less than three seconds
Control Input AC contactor: 120 V AC +10/-25% at 25 mA maximum
Terminals Control input: Compression: Will accept 24 to 16 AWG (0.2 to 1.5 mm2) wire
Line and load: Compression: Will accept 18 to 8 AWG (0.8 to 8.4 mm2) wire
Operating Environment -4 to 176°F (-20 to 80°C); see the output rating curve chart for your application
0 to 90% RH (relative humidity), non-condensing
Insulation tested to 9842.52' (3000 m)
Suitable for "Pollution degree 2"
Agency Approvals CE with proper filter:
204/108/EC Electromagnetic Compatibility Directive
EN 61326-1: Industrial Immunity Class A Emissions
2006/95/EC Low Voltage Directive
EN 50178 Safety Requirements
Installation category III, pollution degree 2

UL® 508 listed and C-UL® File E73741
2011/65/EU RoHS 2
Mounting Options include DIN-rail or standard back panel mounting
DIN EN 50022, 1.4 x 0.3" (35 x 7.5 mm)
Mount cooling fins vertically
Dimensions 3.7 x 2 x 3.9" (94 x 50 x 98 mm)
Weight 0.71 lbs (0.32 kg)
Click here for complete specifications on the Watlow DA10-02K2-0000

What's included with the Watlow DA10-02K2-0000

  • Power Controller
  • Three-Year Warranty

Ask a question about Watlow DIN-A-MITE A Solid State Power Controller, 24 to 48 V AC, 100 to 120 V AC input