Insulation tester designed to test the quality of insulation using 5000V test voltages. It is ideal for testing large motors, generators, transformers and cables. Performs voltage, insulation, and capacitance measurements.

Insulation tester designed to test the quality of insulation using 5000V test voltages. It is ideal for testing large motors, generators, transformers and cables. Performs voltage, insulation, and capacitance measurements.

Sale Price $2707.50 USD
Regular Price $2850.00 USD
Availability 1 Week
Quantity

Traceable In-House Calibration Certificate for your 6505 Digital Megohmmeter with Analog Bargraph and Auto DAR/PI

Traceable In-House Calibration Certificate for your 6505 Digital Megohmmeter with Analog Bargraph and Auto DAR/PI

AEMC Instruments 6505 Offers

This portable instrument is housed in a rugged field case and operates on either battery or line power that performs voltage, insulation, and capacitance measurements. This instrument contributes to the safety of electrical installations and equipment.

Displays the test voltage, insulation resistance and the leakage current during the test. Capacitance of the sample and discharge voltage present at the test leads is displayed at the conclusion of the test.

Designed with the highest level of built-in safety features. This meter incorporates test inhibit capabilities which will not allow test voltages to be generated if a live sample is detected. The test terminals are recessed to ensure operating safety.

Features

  • Test voltage combination of 500V, 1000V, 2500V and 5000V
  • Insulation measurements from 30kΩ to 10TΩ
  • Adjustable and programmable test voltage (40 to 5100V)
  • Automatic calculation of DAR and PI values
  • Direct measurement and display of Capacitance and Leakage Current
  • Display of resistance, test voltage and run time
  • Programmable test run times and PI ratio times
  • Automatic test inhibition, if live sample (>25)
  • Automatic discharge and display of discharge voltage
  • Large dual-display with time, voltage and measurements shown
  • Rugged dual wall weatherproof field case
  • Designed and built to IEC safety standards
  • EN 61010-1, 1000V CAT III

Applications

  • Test insulation on cables, transformers, motors, generators, insulators and wiring installations
  • High resistance or absorption tests
  • Spot reading tests
  • Timed resistance measurements
  • Dielectric Absorption Ratio (DAR) and Polarization Index (PI) tests
  • Test old or water damaged installations over long time runs
  • Motor insulation resistance measurements

AEMC Instruments 6505 Specifications

Test Voltage/Range 500V: 30kΩ to 2000GΩ (2TΩ)
1000V: 100kΩ to 4000GΩ (4TΩ)
2500V: 100kΩ to 10,000GΩ (10TΩ)
5000V: 300kΩ to 10,000GΩ (10TΩ)
User Programmable Test 40 to 1000V: 10V increments
1000 to 5100V: 100V increments
Short Circuit Current <1.6mA ± 5%
Accuracy 10kΩ to 40GΩ: ±5% of Reading ± 3cts
40GΩ to 10TΩ: ±15% of Reading ± 10cts
DAR (1 min/30 sec) 0.02 to 50.00
PI (10 min/1 min & user programmable) 0.02 to 50.00
Capacitance Measurement 0.005 to 49.99µF
Max resolution 1nF
Leakage Current Measurement 0.00nA to 3mA
Max resolution 1pA
Programmable Run Time R(t) 1 to 60 minutes
Discharge After Test Yes, automatic
Discharge Voltage Display Yes
Voltage Test/Safety Check 0 to 1000V AC/DC (16 to 420Hz)
1V Resolution
Click here for complete specifications on the AEMC Instruments 6505

What's included with the AEMC Instruments 6505

  • Digital Megohmmeter
  • Set of 6' Leads, 5000V (Red, Blue, and Black)
  • Set of Alligator Clips, 600V CAT IV, (Red, Blue, and Black)
  • Blue Guard Terminal Jumper Lead
  • Fuse, 0.1A 380V
  • Rechargeable Battery Pack
  • US 115V Power Cord
  • Extra Large Tool Bag
  • Manual

AEMC: Introduction to Insulation Resistance Testing


This video will serve as an introduction to insulation resistance testing. Additionally, it will go over the spot reading test, time-resistance test, and step voltage test which are the three commonly used methods for testing insulation resistance and the user will need a megohmmeter to perform these tests.

Click on a category to view a selection of compatible accessories with the AEMC 6505 Digital Megohmmeter with Analog Bargraph and Auto DAR/PI, 5000V.

AEMC 2151.32 Test Leads with Hippo Clips for the 5050/5060/5070 & 6505, Set of 3, Colour Coded, 25ft 2151.32
Set of 3, 25ft Color-coded 5kV safety leads with integral hippo clips.




AEMC 2119.87 Test Leads with Hippo Clips for the 5050/5060/5070 & 6505, Set of 3, Colour Coded, 45ft 2119.87
Set of 3, 45ft Color-coded 5kV safety lead with integral hippo clips. For use with the 5050, 5060, 5070, and 6505 Megohmmeters. Jumper lead not included.




Ask a question about AEMC 6505 Digital Megohmmeter with Analog Bargraph and Auto DAR/PI, 5000V

Customer Reviews for the AEMC Instruments 6505

AEMC Instruments 6505 Offers

This portable instrument is housed in a rugged field case and operates on either battery or line power that performs voltage, insulation, and capacitance measurements. This instrument contributes to the safety of electrical installations and equipment.

Displays the test voltage, insulation resistance and the leakage current during the test. Capacitance of the sample and discharge voltage present at the test leads is displayed at the conclusion of the test.

Designed with the highest level of built-in safety features. This meter incorporates test inhibit capabilities which will not allow test voltages to be generated if a live sample is detected. The test terminals are recessed to ensure operating safety.

Features

  • Test voltage combination of 500V, 1000V, 2500V and 5000V
  • Insulation measurements from 30kΩ to 10TΩ
  • Adjustable and programmable test voltage (40 to 5100V)
  • Automatic calculation of DAR and PI values
  • Direct measurement and display of Capacitance and Leakage Current
  • Display of resistance, test voltage and run time
  • Programmable test run times and PI ratio times
  • Automatic test inhibition, if live sample (>25)
  • Automatic discharge and display of discharge voltage
  • Large dual-display with time, voltage and measurements shown
  • Rugged dual wall weatherproof field case
  • Designed and built to IEC safety standards
  • EN 61010-1, 1000V CAT III

Applications

  • Test insulation on cables, transformers, motors, generators, insulators and wiring installations
  • High resistance or absorption tests
  • Spot reading tests
  • Timed resistance measurements
  • Dielectric Absorption Ratio (DAR) and Polarization Index (PI) tests
  • Test old or water damaged installations over long time runs
  • Motor insulation resistance measurements

AEMC Instruments 6505 Specifications

Test Voltage/Range 500V: 30kΩ to 2000GΩ (2TΩ)
1000V: 100kΩ to 4000GΩ (4TΩ)
2500V: 100kΩ to 10,000GΩ (10TΩ)
5000V: 300kΩ to 10,000GΩ (10TΩ)
User Programmable Test 40 to 1000V: 10V increments
1000 to 5100V: 100V increments
Short Circuit Current <1.6mA ± 5%
Accuracy 10kΩ to 40GΩ: ±5% of Reading ± 3cts
40GΩ to 10TΩ: ±15% of Reading ± 10cts
DAR (1 min/30 sec) 0.02 to 50.00
PI (10 min/1 min & user programmable) 0.02 to 50.00
Capacitance Measurement 0.005 to 49.99µF
Max resolution 1nF
Leakage Current Measurement 0.00nA to 3mA
Max resolution 1pA
Programmable Run Time R(t) 1 to 60 minutes
Discharge After Test Yes, automatic
Discharge Voltage Display Yes
Voltage Test/Safety Check 0 to 1000V AC/DC (16 to 420Hz)
1V Resolution
Click here for complete specifications on the AEMC Instruments 6505

What's included with the AEMC Instruments 6505

  • Digital Megohmmeter
  • Set of 6' Leads, 5000V (Red, Blue, and Black)
  • Set of Alligator Clips, 600V CAT IV, (Red, Blue, and Black)
  • Blue Guard Terminal Jumper Lead
  • Fuse, 0.1A 380V
  • Rechargeable Battery Pack
  • US 115V Power Cord
  • Extra Large Tool Bag
  • Manual

AEMC: Introduction to Insulation Resistance Testing


This video will serve as an introduction to insulation resistance testing. Additionally, it will go over the spot reading test, time-resistance test, and step voltage test which are the three commonly used methods for testing insulation resistance and the user will need a megohmmeter to perform these tests.

Click on a category to view a selection of compatible accessories with the AEMC 6505 Digital Megohmmeter with Analog Bargraph and Auto DAR/PI, 5000V.

AEMC 2151.32 Test Leads with Hippo Clips for the 5050/5060/5070 & 6505, Set of 3, Colour Coded, 25ft 2151.32
Set of 3, 25ft Color-coded 5kV safety leads with integral hippo clips.




AEMC 2119.87 Test Leads with Hippo Clips for the 5050/5060/5070 & 6505, Set of 3, Colour Coded, 45ft 2119.87
Set of 3, 45ft Color-coded 5kV safety lead with integral hippo clips. For use with the 5050, 5060, 5070, and 6505 Megohmmeters. Jumper lead not included.




Ask a question about AEMC 6505 Digital Megohmmeter with Analog Bargraph and Auto DAR/PI, 5000V

Customer Reviews for the AEMC Instruments 6505

More AEMC Instruments Products