Ideal for electricians, engineers, and contractors working on system monitoring and upgrades for buildings or energy audits, this data logger lets you generate reports with confidence and minimal configuration time. In addition, measure, record, and analyze vital energy data for 50 Hz, 60 Hz, 400 Hz, and DC distribution systems.
Ideal for electricians, engineers, and contractors working on system monitoring and upgrades for buildings or energy audits, this data logger lets you generate reports with confidence and minimal configuration time. In addition, measure, record, and analyze vital energy data for 50 Hz, 60 Hz, 400 Hz, and DC distribution systems.
The design of the Logger allows it to be installed inside a load centre panel (including the current sensors) enabling the door to close on most panels. The PEL 103 offers all the essential functions for logging power/energy data from most current electrical power networks 17 network set-ups provided. Measure and record three voltage inputs and current inputs, Watts, VARS, VA and Energy (kWh and kVA). Power Factor (PF), Displacement Power Factor (DPF), Crest Factor, Frequency and THD are calculated and recorded. Individual harmonic % information from 1 to the 50th harmonic are recorded at the operator's choice. All variables are recorded and stored at a one second interval as well as user selectable demand intervals from 1 to 60 minutes.
Energy costs can be quickly and easily calculated and displayed by simply entering the unit cost for a kilowatt hour into the software. Data is stored on a removable SD card. Data can be retrieved using a Bluetooth, USB and/or Ethernet (local or internet) connection by transporting the SD card back to a PC. The comprehensive DataView® software (included) provides the ability to view data from several hundred PEL 100 series instruments on a local network or over the internet allowing the user to evaluate energy usage in a department or facility basis, a remote site, or even in a city, anywhere in the world. DataView® allows measurements to be seen in real-time on a PC and stored data to be downloaded for analysis and report generation.
Features
Applications
Sampling Frequency | 128 samples per cycle: 50/60 Hz (16 samples/cycle 400 Hz) |
Data Storage Rate | 1 per second |
Demand Period Storage Rate | User selectable (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 and 60 minutes) |
Recorded Parameters (Single and Poly-Phase) | V, I, W, VA, var, PF, Tan, Wh, Vah, varh, THD (V and I) Individual harmonics (from 1 through 50 per phase); Crest Factor (CF), Cos f / DPF |
Event Log | Tracks and records status changes and error messages along with recorded data |
Front Panel Indicator LEDs | Bluetooth active, recording in progress, phase connection reversal, overload, battery charging and SD Card status |
Storage Capacity | 2GB SD card (included) is used for storage. SD cards (up to 2GB); SDHC cards (4 to 32GB) formatted FAT32 are supported |
Inputs | Voltage: 3 voltage input channels via 4mm safety banana jacks Current: 3 current input channels via custom 4 pin jacks that accept AEMC® probes and sensors |
Communication Ports | USB 2.0, Ethernet (RJ45), Wireless Bluetooth Class |
Mounting | Embedded magnets on back side, keyhole slot on back side |
Security | Kensington anti-theft system |
Index of Protection | IP54 non operating |
Safety Rating/CE Rating | Complies with IEC 61010-1:Ed3, and IEC 61010-2-030:Ed1 for 1000V CAT III/600V CAT IV, Pollution Degree 2/Yes |
Case | Double insulated, rubber over-molded, polycarbonate UL94 V1 rated |
Dimensions | 10.08 x 4.92 x 1.46" (256 x 125 x 37 mm) |
Weight | <2.2 lbs (<1 kg) |
Sampling Frequency | 128 samples per cycle: 50/60 Hz (16 samples/cycle 400 Hz) |
Data Storage Rate | 1 per second |
Demand Period Storage Rate | User selectable (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 and 60 minutes) |
Recorded Parameters (Single and Poly-Phase) | V, I, W, VA, var, PF, Tan, Wh, Vah, varh, THD (V and I) Individual harmonics (from 1 through 50 per phase); Crest Factor (CF), Cos f / DPF |
Event Log | Tracks and records status changes and error messages along with recorded data |
Front Panel Indicator LEDs | Bluetooth active, recording in progress, phase connection reversal, overload, battery charging and SD Card status |
Storage Capacity | 2GB SD card (included) is used for storage. SD cards (up to 2GB); SDHC cards (4 to 32GB) formatted FAT32 are supported |
Inputs | Voltage: 3 voltage input channels via 4mm safety banana jacks Current: 3 current input channels via custom 4 pin jacks that accept AEMC® probes and sensors |
Communication Ports | USB 2.0, Ethernet (RJ45), Wireless Bluetooth Class |
Mounting | Embedded magnets on back side, keyhole slot on back side |
Security | Kensington anti-theft system |
Index of Protection | IP54 non operating |
Safety Rating/CE Rating | Complies with IEC 61010-1:Ed3, and IEC 61010-2-030:Ed1 for 1000V CAT III/600V CAT IV, Pollution Degree 2/Yes |
Case | Double insulated, rubber over-molded, polycarbonate UL94 V1 rated |
Dimensions | 10.08 x 4.92 x 1.46" (256 x 125 x 37 mm) |
Weight | <2.2 lbs (<1 kg) |