Easy to use, portable, and rugged, this single/dual-phase power and energy logger operates in 600 V CAT III or lower environments and records voltage, power, and energy on alternating current distribution networks. In addition, this analyzer features a large, backlit LCD for crisp viewing and an SD card to store measurements.
Easy to use, portable, and rugged, this single/dual-phase power and energy logger operates in 600 V CAT III or lower environments and records voltage, power, and energy on alternating current distribution networks. In addition, this analyzer features a large, backlit LCD for crisp viewing and an SD card to store measurements.
Compact enough to fit into various distribution panels, this power and energy analyzer features water and shock-resistant housing, operates on phase 1 input, and includes a backup battery that charges from the V1 input during measurements.
Features
Applications
Key Specifications | |
Inputs | 2V/2I |
Types of Installations | Single-phase, split-phase, or two single-phase channels |
Recording/Data Storage Rate | Unlimited duration (4 GB maximum recording size)/1 second to 1 hour (minimum/average/maximum) |
Network Frequency | 45 to 65 Hz |
Voltage | 10 to 600 V |
Electrical | |
Voltage | Range: Vrms: 10 to 660 V P to N Urms: 20 to 1200 V P to P Resolution: Vrms/Urms: 0.1 V Accuracy: Vrms: ±0.2% reading ±0.2 V Urms: ±0.2% reading ±0.4 V |
Current Measurement at 50 and 60 Hz | Amps (1 V nominal); excluding clamp accuracy Range: Probe dependent (0.2% < I < 120% Inom) Resolution: Probe dependent Accuracy: ±0.2% reading ±0.02 Inom |
Power | Watts P-Q-S (W-var-VA) Range: V = 100 to 660 V; I = 5 to 120% Inom Resolution: Probe dependent Accuracy: ±0.3% R ±0.003% Pnom ±1% R ±0.01% Qnom ±0.3% R ±0.003% Snom Power factor Range: -1 to 1 Resolution: 0.001 Accuracy: ±0.02% Cos φ (DPF): Range: -1 to 1 Resolution: 0.001 Accuracy: ±0.05% |
Energy | Ep-Eq-Es (Wh, varh, VAh) Range: V = 100 to 660 V; I = 5 to 120% Inom Resolution: 0.001 and ±0.02% Accuracy: ±0.5% reading ±2.5% reading ±0.5% reading |
General Specifications | |
Communication | Wi-Fi (access point and hot spot) |
Data Storage | 8 GB SD card (included); expandable to 32 GB |
Display Type | LCD with blue backlight |
Real-Time Clock | Time and date stamp for Trend mode |
Environmental | Operating temperature/relative humidity: -4 to 122°F (-20 to 50°C)/10 to 85% RH Storage temperature/relative humidity: -40 to 158°F (-40 to 70°C)/0 to 95% RH without battery |
Safety | Electro-Magnetic Compatibility (EMC): EN 61326-1 for emission and immunity Safety rating/CE rating: IEC/EN 61010-2-30 (600 V CAT III)/Yes IP rating: IP54 per IEC 60529 |
Case | Compact and rugged, shock and vibration IEC 61010 |
Power Supply | From phase 1, 90 to 660 V battery backup when power OFF Battery life: 3 hours without Wi-Fi, 1 hour typical with Wi-Fi enabled |
Dimensions | 7.08 x 3.46 x 1.45" (180 x 88 x 37 mm) |
Weight | 14.1 oz (400 g) |
Click on a category to view a selection of compatible accessories with the AEMC PEL 52 Power and Energy Logger, 10 to 600 V, CAT III 600 V.
Key Specifications | |
Inputs | 2V/2I |
Types of Installations | Single-phase, split-phase, or two single-phase channels |
Recording/Data Storage Rate | Unlimited duration (4 GB maximum recording size)/1 second to 1 hour (minimum/average/maximum) |
Network Frequency | 45 to 65 Hz |
Voltage | 10 to 600 V |
Electrical | |
Voltage | Range: Vrms: 10 to 660 V P to N Urms: 20 to 1200 V P to P Resolution: Vrms/Urms: 0.1 V Accuracy: Vrms: ±0.2% reading ±0.2 V Urms: ±0.2% reading ±0.4 V |
Current Measurement at 50 and 60 Hz | Amps (1 V nominal); excluding clamp accuracy Range: Probe dependent (0.2% < I < 120% Inom) Resolution: Probe dependent Accuracy: ±0.2% reading ±0.02 Inom |
Power | Watts P-Q-S (W-var-VA) Range: V = 100 to 660 V; I = 5 to 120% Inom Resolution: Probe dependent Accuracy: ±0.3% R ±0.003% Pnom ±1% R ±0.01% Qnom ±0.3% R ±0.003% Snom Power factor Range: -1 to 1 Resolution: 0.001 Accuracy: ±0.02% Cos φ (DPF): Range: -1 to 1 Resolution: 0.001 Accuracy: ±0.05% |
Energy | Ep-Eq-Es (Wh, varh, VAh) Range: V = 100 to 660 V; I = 5 to 120% Inom Resolution: 0.001 and ±0.02% Accuracy: ±0.5% reading ±2.5% reading ±0.5% reading |
General Specifications | |
Communication | Wi-Fi (access point and hot spot) |
Data Storage | 8 GB SD card (included); expandable to 32 GB |
Display Type | LCD with blue backlight |
Real-Time Clock | Time and date stamp for Trend mode |
Environmental | Operating temperature/relative humidity: -4 to 122°F (-20 to 50°C)/10 to 85% RH Storage temperature/relative humidity: -40 to 158°F (-40 to 70°C)/0 to 95% RH without battery |
Safety | Electro-Magnetic Compatibility (EMC): EN 61326-1 for emission and immunity Safety rating/CE rating: IEC/EN 61010-2-30 (600 V CAT III)/Yes IP rating: IP54 per IEC 60529 |
Case | Compact and rugged, shock and vibration IEC 61010 |
Power Supply | From phase 1, 90 to 660 V battery backup when power OFF Battery life: 3 hours without Wi-Fi, 1 hour typical with Wi-Fi enabled |
Dimensions | 7.08 x 3.46 x 1.45" (180 x 88 x 37 mm) |
Weight | 14.1 oz (400 g) |
Click on a category to view a selection of compatible accessories with the AEMC PEL 52 Power and Energy Logger, 10 to 600 V, CAT III 600 V.