Reduce installation and system operating costs with this transmitter that features a 4 to 20 mA range and 2% accuracy. Highly accurate and reliable, monitor and control temperatures and humidity with this transmitter that features long-term stability and a sensor to reduce the effects of condensation, fog, or high humidity.
Reduce installation and system operating costs with this transmitter that features a 4 to 20 mA range and 2% accuracy. Highly accurate and reliable, monitor and control temperatures and humidity with this transmitter that features long-term stability and a sensor to reduce the effects of condensation, fog, or high humidity.
Features
Applications
Relative Humidity Range | 0 to 100% RH |
Temperature | Range: -40 to 140°F (-40 to 60°C) Limits: -40 to 140°F (-40 to 60°C) Storage: -40 to 176°F (-40 to 80°C) Compensated range: -4 to 140°F (-20 to 60°C) |
Accuracy | RH: ±2% 10 to 90% RH at 77°F (25°C) Thermistor temperature sensor: ±0.36°F at 77°F (±0.2°C at 25°C) RTD temperature sensor: DIN Class B; ±0.54°F at 32°F (±0.3°C at 0°C) Solid state band gap: ±0.9°F at 77°F (±0.5°C at 25°C) |
Hysteresis | ±1% |
Repeatability | ±0.1% typical |
RH Sensor | Capacitance polymer |
Output Signal (Model Dependent) | 4 to 20 mA 0 to 5/10 V at 5 mA maximum |
Response Time | 15 seconds |
Display | Duct mount only Resolution: RH: 0.1%; 0.1°F (0.1°C) |
Connections | Electrical: Removable screw terminal block Conduit: Duct mount: ½" NPS; OSA: PG11 or PG16 (½" conduit) knockouts |
Drift | <1% RH/year |
Enclosure Material | Duct mount sensor tube: PVC-UL 94 V-0 Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0 Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB OSA: Polycarbonate |
Power Requirements | 10 to 35 V DC |
Compliance | CE |
Dimensions | 5.12 x 2.25 x 6.78" (130.18 x 57.15 x 172.16 mm) |
Weight | Duct mount: 0.616 lbs (0.3 kg) OSA: 1 lbs (0.45 kg) |
Relative Humidity Range | 0 to 100% RH |
Temperature | Range: -40 to 140°F (-40 to 60°C) Limits: -40 to 140°F (-40 to 60°C) Storage: -40 to 176°F (-40 to 80°C) Compensated range: -4 to 140°F (-20 to 60°C) |
Accuracy | RH: ±2% 10 to 90% RH at 77°F (25°C) Thermistor temperature sensor: ±0.36°F at 77°F (±0.2°C at 25°C) RTD temperature sensor: DIN Class B; ±0.54°F at 32°F (±0.3°C at 0°C) Solid state band gap: ±0.9°F at 77°F (±0.5°C at 25°C) |
Hysteresis | ±1% |
Repeatability | ±0.1% typical |
RH Sensor | Capacitance polymer |
Output Signal (Model Dependent) | 4 to 20 mA 0 to 5/10 V at 5 mA maximum |
Response Time | 15 seconds |
Display | Duct mount only Resolution: RH: 0.1%; 0.1°F (0.1°C) |
Connections | Electrical: Removable screw terminal block Conduit: Duct mount: ½" NPS; OSA: PG11 or PG16 (½" conduit) knockouts |
Drift | <1% RH/year |
Enclosure Material | Duct mount sensor tube: PVC-UL 94 V-0 Duct mount sensor cap: Polycarbonate ABS blend-greater than UL 94 V-0 Duct mount electronics housing and cover: Makrolon® polycarbonate-UL 94V-HB OSA: Polycarbonate |
Power Requirements | 10 to 35 V DC |
Compliance | CE |
Dimensions | 5.12 x 2.25 x 6.78" (130.18 x 57.15 x 172.16 mm) |
Weight | Duct mount: 0.616 lbs (0.3 kg) OSA: 1 lbs (0.45 kg) |